| Plan Review Stops For Permit 03070239 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-08-01 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2003-08-01 |
Time |
15:10 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-07-21 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-10 |
Time |
10:01 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2003-07-21 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2003-07-21 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03070239 | | | ADD: 1675B FORUM PLACE | | | CONT: BEJAI P MANAGAR | | | TEL: (561)239-1040 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | ACTION: DENIED | | | | | | 1) 11.3.3 WIDTH. THE MINIMUM CLEAR WIDTH | | | OF AN ACCESSIBLE ROUTE SHALL BE 36" | | | EXCEPT AT DOORS. IF A PERSON IN A WHEEL- | | | CHAIR MUST MAKE A TURN AROUND AROUND AN | | | OBSTRUCTION, THE MINIMUM CLEAR WIDTH OF | | | THE OBSTRUCTION, THE MINIMUM CLEAR WIDTH | | | OF THE ACCESSIBLE ROUTE SHALL BE AS | | | SHOWN IN FIGURE 7(A) AND (B). | | | | | | 2)11-4.13.6 MANEUVERING CLEARENCES | | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARENCES SHALL BE | | | CLEAR & LEVEL. | | | | | | 3) 11-4.23.3 CLEAR FLOOR SPACE, AN UN- | | | OBSTRUCTED TURNING SPACE COMPLYING WITH | | | 11-4.2.3. A HANDICAPPED PERSON CAN'T | | | EVEN MAKE IT TO THE WATER CLOSET, OR | | | HOLD ON TO THE GRAB BARS TO MAKE A TRANS | | | FER TO THE WATER CLOSET!!!! | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-08-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-08-01 |
Time |
13:06 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-08-01 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2003-08-01 00:00:00 | REDLINED EQUIPMENT GROUNDING CONDUCTOR. | | | FROM MAIN TO PANEL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-07-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-07-17 |
Time |
07:46 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-07-17 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2003-07-17 00:00:00 | ************* UNSAT ***************** | | | | | | 1)NOTE: : PLEASE SHOW ALL CIRCUITING ON | | | PLANS. PLEASE CORRELATE W/ SUBMITTED | | | PANEL SCHEDULE. | | | | | | 2)NOTE: PLEASE SEE REQ'D GFI PROTECTION | | | FOR KITCHENS. 210.8B | | | | | | 3)NOTE: PLEASE SEE ATTACHED SHEET FOR | | | FAC 61G15-23.002 AND REQ'D INFORMATION | | | FOR TITLE BLOCK INCLUDING AUTHORIZATION | | | #. | | | | | | 4)NOTE: PLEASE CORRELATE CIRCUITING AND | | | PANEL SCHEDULES. CIRCUIT A-1 SHOWN AS | | | KITCHEN COUNTER RECEPT AND PANEL SHOWS | | | A/C UNITS.? | | | ALOS SHOWS SAME CIRCUIT FEEDING OTHER | | | RECEPTS FOR OTHER EQUIPMENT? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2003-07-16 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-07-16 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-07-16 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2003-07-16 00:00:00 | **********PROVISO*********************** | | | NO COOKING TO PREVENT FROM PRODUCING | | | GREASE LADEN VAPORS. | | | INTERIOR FINISH CLASSIFICATION SHALL BE | | | CLASS "A" OR CLASS "B" FOR THE WALLS AND | | | CEILINGS. | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-07-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-30 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-30 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2003-07-30 00:00:00 | TO BLDG COMM BD #16 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-07-11 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-10 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-10 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2003-07-10 00:00:00 | COMM BOARD #9 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-07-07 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-07 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-07 |
Time |
09:16 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-08-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-06 |
Time |
13:52 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-08-06 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2003-08-06 00:00:00 | PROVISO - SAMPLE POINT REQUIRED - SHEET | | | FROM METRO DESIGN TO BE SUBMITTED WITH | | | STAMP FROM DBPR FOR FILE COPY |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-07-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-23 |
Time |
14:36 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-07-23 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2003-07-23 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | FBC-2001 AMENDMENTS, CHAPTER | | | ONE | | | FLORIDA STATUTES | | | | | | 1) BOTH SETS OF PLANS SHALL BE STAMPED | | | BY THE DBPR HOTEL AND RESTURANT DIVISION | | | AND RELATED SPECIFICATION SHEETS SHALL | | | BE AFFIXED TO BOTH SETS. 104.2.1 | | | 2) SHOW ALL DIMENTIONS FOR THE TOILET | | | ROOM. SHOW CLEAR FLOOR SPACE PER SECTION | | | 11-4.16.2 & 11-4.19.3 | | | 3) SUMBIT A WATER RISER DIAGRAM - SECT- | | | ION 104.3.1.1 PLUMBING(3) | | | 4) SHT A2 PLUMBING NOTES/GAS NOTES, A | | | SEPARATE PERMIT AND SET OF PLANS SHALL | | | BE REQUIRED FOR GAS. | | | 5) 61G15-23.002(2) AUTHORIZATION NUMBER | | | REQUIRED IN TITLE BLOCK. | | | 6) CONTACT RODNEY COMPO, INDUSTRIAL PRE- | | | TREATMENT, ENVIRONMENTAL COMPLIANCE. HE | | | SHALL DETERMINE IF A GREASE TRAP WILL BE | | | REQUIRED, AND IF SO THE SIZE REQUIRED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2003-07-09 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-07 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|