Plan Review Details - Permit 03070231
Plan Review Stops For Permit 03070231
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-07-29 Cont ID  
Sent By btrobaug Date 2004-02-12 Time 10:07 Rev Time 0.50
Received By lsmith Date 2003-07-29 Time 07:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-02-12 Cont ID  
Sent By btrobaug Date 2004-02-12 Time 10:07 Rev Time 0.25
Received By btrobaug Date 2004-02-12 Time 09:53 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-07-23 Cont ID  
Sent By kstevens Date 2004-02-11 Time 17:14 Rev Time 0.25
Received By dpalmer Date 2003-07-23 Time 11:51 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-07-16 Cont ID  
Sent By shernand Date 2003-07-21 Time 10:02 Rev Time 0.25
Received By dpalmer Date 2003-07-16 Time 07:17 Sent To B
Notes
2003-07-16 00:00:00************ UNSAT ****************
  
 1)NOTE: PLEASE CORRELATE ELECTRICAL/-
 WIRING DIAGRAM AND POOL EQUIPMENT SPECS.
  
 PLEASE INCLUDE ALL PUMPS,BLOWERS,HEATERS
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-21 Cont ID  
Sent By mmclean Date 2004-02-11 Time 16:15 Rev Time 0.00
Received By shernand Date 2003-07-21 Time 10:02 Sent To E
Notes
2003-07-21 00:00:00DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-07-07 Cont ID  
Sent By shernand Date 2003-07-07 Time 11:24 Rev Time 0.00
Received By shernand Date 2003-07-07 Time 11:24 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-02-11 Cont ID  
Sent By kstevens Date 2004-02-11 Time 17:14 Rev Time 0.50
Received By kstevens Date 2004-02-11 Time 17:13 Sent To E
Notes
2004-02-11 00:00:00RESTAMP OK

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-07-29 Cont ID  
Sent By kstevens Date 2003-07-29 Time 07:50 Rev Time 0.50
Received By kstevens Date 2003-07-29 Time 07:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-07-12 Cont ID  
Sent By dpalmer Date 2003-07-23 Time 11:51 Rev Time 0.50
Received By kstevens Date 2003-07-12 Time 05:24 Sent To E
Notes
2003-07-12 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 2) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 3) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
 4) FBC-2001 424.2.14.4 CONNECTIONS, ALL
 WATER HEATING EQUIPMENT SHALL BE INSTAL-
 LED WITH FLANGES OR UNION CONNECTIONS
 ADJACENT TO THE HEATER. (ADD TO NOTES)
 5) FBC02001 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692

Review Stop Z ZONING
Rev No 2 Status P Date 2004-02-11 Cont ID  
Sent By mmclean Date 2004-02-11 Time 16:15 Rev Time 0.00
Received By mmclean Date 2004-02-11 Time 16:15 Sent To I
Notes
2004-02-11 00:00:00RE-STAMP PLANS

Review Stop Z ZONING
Rev No 1 Status P Date 2003-07-10 Cont ID  
Sent By shernand Date 2003-07-07 Time 11:24 Rev Time 1.00
Received By mmclean Date   Time   Sent To P
Notes
***NONE***