Plan Review Details - Permit 03070149
| Plan Review Stops For Permit 03070149 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-08-18 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-08-18 |
Time |
12:18 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-08-18 |
Time |
12:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-07-30 |
|
|
Cont ID |
|
| Sent By |
dbaxter |
Date |
2003-08-14 |
Time |
15:44 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-07-29 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2003-07-29 00:00:00 | NOTES - | | | | | | CALLED CONTRACTOR; SHE IS TO FAX | | | MFG SPECS SHOWING THAT THE WINDOWS ON | | | 1ST & 2ND FLOORS COMPLY W/FBC1005.4 | | | | | | FAXED HER A HURRICANE SHUTTER | | | ATTACHMENT SCHEDULE. | | | | | | SAID THAT THERE IS A WOOD DOOR FOR | | | EMERGENCY EGRESS, WILL SEND W/FAX | | | AND LOCATIONS OF DOORS TO BE SHUTTERED | | | IF SHE IS SHUTTERING EX DOORS.IF NOT, | | | WILL CHANGE PERMIT APPLICATION. | | | | | | CONTRACTOR IS TO FAX INFORMATION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-07-09 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-29 |
Time |
09:44 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-07-09 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2003-07-09 00:00:00 | ******CORRECTIONS******* | | | | | | 1.)PROVIDE A FOOTPRINT OF THE HOUSE | | | SHOWING ALL WINDOW LOCATIONS.PROVIDE | | | A WINDOW SCHEDULE SHOWING WINDOW | | | SIZES AND TYPES.SHOW ANY BEDROOM | | | WINDOWS OR BATHROOM WINDOWS.ALL | | | WINDOW INSTALLATIONS MUST COMPLY WITH | | | FBC1005.4 (EMERGENCY EGRESS FOR | | | BEDROOMS) AND FBC 2405.1 (SAFETY GLASS). | | | | | | 2.)THE STRUCTURAL TEST REQUIRED FOR | | | WINDOWS IS ASTM E330-84 (FBC1706.1, | | | FBC35).THE TEST REPORTS SUBMITTED | | | DID NOT USE THE TEST REQUIRED BY THE | | | FLORIDA BUILDING CODE.PLEASE | | | ADDRESS. | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-08-14 |
|
|
Cont ID |
|
| Sent By |
dbaxter |
Date |
2003-08-14 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
dbaxter |
Date |
2003-08-14 |
Time |
15:44 |
Sent To |
B |
|
| Notes |
| 2003-08-14 00:00:00 | TO STHYNG DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-07-29 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-29 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-29 |
Time |
09:44 |
Sent To |
B |
|
| Notes |
| 2003-07-29 00:00:00 | TO STHYNG DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-07-07 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-07 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-07 |
Time |
15:39 |
Sent To |
B |
|
| Notes |
| 2003-07-07 00:00:00 | MISC BOX |
|
|
|