Plan Review Details - Permit 03062189
Plan Review Stops For Permit 03062189
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-08-11 Cont ID  
Sent By hpiskura Date 2003-08-11 Time 09:13 Rev Time 0.00
Received By hpiskura Date 2003-08-11 Time 09:12 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-07-11 Cont ID  
Sent By hpiskura Date 2003-07-11 Time 15:08 Rev Time 0.00
Received By hpiskura Date 2003-07-11 Time 15:08 Sent To  
Notes
2003-07-11 00:00:00PLAN REVIEW NOT A PERMIT APPLICATION.
  
 THE NEW OFFICE/SALES AREA IS REQUIRED BY
 FBC 411.5.3 TO BE SEPARATED FROM THE
 EXISTING REPAIR GARAGE BY TWO HOUR FIRE
 RATED CONSTRUCTION.
  
 THE NEW STORE FRONT MUST COMPLY WITH
 THE HURRICANE MISSILE IMPACT RESISTANCE
 REQUIREMENTS OF FBC 1606.1.4.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-08-11 Cont ID  
Sent By dpalmer Date 2003-08-11 Time 11:51 Rev Time 0.50
Received By dpalmer Date 2003-08-11 Time 11:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-07-14 Cont ID  
Sent By dpalmer Date 2003-07-14 Time 09:36 Rev Time 0.50
Received By dpalmer Date 2003-07-14 Time 09:36 Sent To  
Notes
2003-07-14 00:00:00PASSED PENDING COMMENTS FROM OTHER
 REVIEWERS.
 PLEASE ALSO NOTE, PLANS WERE ONLY
 SUBMITTED FOR PLAN REVIEW AND NOT FOR
 PERMIT APPLICATION. PLEASE NOTE ON PLANS
 AS OF 7/1/03 WE ARE NOW UNDER THE 2002
 NEC. PLEASE ADJUST COVER SHEET.
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-08-20 Cont ID  
Sent By nmccray Date 2003-08-20 Time 15:39 Rev Time 0.00
Received By nmccray Date 2003-08-20 Time 15:39 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2003-07-16 Cont ID  
Sent By nmccray Date 2003-07-16 Time 11:35 Rev Time 0.00
Received By nmccray Date 2003-07-16 Time 11:35 Sent To  
Notes
2003-07-16 00:00:001) INTERIOR FINISH CLASSIFICATION FOR
 WALLS AND CEILINGS SHALL BE CLASS "A",
 CLASS "B" OR CLASS "C".
  
 2) SEPARATE SHOP DRAWINGS AND PERMIT
 APPLICATIONS ARE REQUIRED FOR FIRE ALARM
 AND FIRE SPRINKLER SYSTEMS REMODEL.
  
 3) PLEASE REF NFPA 101 LIFE SAFETY CODE
 2000 EDITION
  
 NATE MCCRAY, CAPTAIN
 805-6722 OR 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-09-09 Cont ID  
Sent By csiegber Date 2003-09-09 Time 11:48 Rev Time 0.00
Received By csiegber Date 2003-09-09 Time 11:48 Sent To M
Notes
2003-09-09 00:00:00TO PK DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-07-01 Cont ID  
Sent By shernand Date 2003-07-01 Time 11:04 Rev Time 0.00
Received By shernand Date 2003-07-01 Time 11:04 Sent To  
Notes
2003-07-01 00:00:00COMM BOARD #44

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-09-12 Cont ID  
Sent By pkrauss Date 2003-09-12 Time 10:09 Rev Time 0.25
Received By pkrauss Date 2003-09-12 Time 10:09 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2003-08-18 Cont ID  
Sent By csiegber Date 2003-09-09 Time 11:48 Rev Time 0.35
Received By pkrauss Date 2003-08-18 Time 13:19 Sent To  
Notes
2003-08-18 00:00:00DENIED:
 1. PREVIOUS COMMENTS NOT ADDRESSED.
  
 - CONDENSATE SHALL NOT DISCHARGE INTO
 THE SANITARY DRAIN.
  
 2. PROVIDE OUTSIDE AIR CALCULATIONS AS
 PER 2001 FBC(M) TABLE 403.3 & ASHRAE
 62-89.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-07-09 Cont ID  
Sent By pkrauss Date 2003-07-09 Time 15:52 Rev Time 0.45
Received By pkrauss Date 2003-07-09 Time 15:52 Sent To  
Notes
2003-07-09 00:00:00DENIED:PLAN CHECK
  
 1.PLAN SHEET MP-1 DETAIL OF THE THRU
 THE WALL AIR CONDITIONER, NOTE
 INDICATESCONDENSATE TO DISCHARGE TO
 NEAREST FLOORDRAIN.AS PER CITY CODE
 SEC. 90-125 (B), DISCHARGE PROHIBITIONS
 NO USER SHALL DISCHARGE INTO THE WASTE
 WATER FACILITY: (5), CONDENSATE.
  
 2.PLEASE CLARIFY FIRE RATING OF
 WALL BETWEEN THE BATTERY STORAGE AND
 OFFICE / SALES.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-07-09 Cont ID  
Sent By kstevens Date 2003-07-09 Time 17:40 Rev Time 0.75
Received By kstevens Date 2003-07-09 Time 17:11 Sent To  
Notes
2003-07-09 00:00:00PASSED/PROVISO - A/C CONDENSATE SHALL
 NOT DRAIN INTO SANITARY. CITY ORDINANCE
 #90-125

Review Stop Z ZONING
Rev No 1 Status N Date 2003-09-12 Cont ID  
Sent By pkrauss Date 2003-09-12 Time 10:25 Rev Time 0.05
Received By pkrauss Date 2003-09-12 Time 10:25 Sent To  
Notes
***NONE***