| Plan Review Stops For Permit 03062189 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-08-11 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-08-11 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-08-11 |
Time |
09:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-07-11 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-07-11 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-07-11 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2003-07-11 00:00:00 | PLAN REVIEW NOT A PERMIT APPLICATION. | | | | | | THE NEW OFFICE/SALES AREA IS REQUIRED BY | | | FBC 411.5.3 TO BE SEPARATED FROM THE | | | EXISTING REPAIR GARAGE BY TWO HOUR FIRE | | | RATED CONSTRUCTION. | | | | | | THE NEW STORE FRONT MUST COMPLY WITH | | | THE HURRICANE MISSILE IMPACT RESISTANCE | | | REQUIREMENTS OF FBC 1606.1.4. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-08-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-08-11 |
Time |
11:51 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-08-11 |
Time |
11:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-07-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-07-14 |
Time |
09:36 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-07-14 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2003-07-14 00:00:00 | PASSED PENDING COMMENTS FROM OTHER | | | REVIEWERS. | | | PLEASE ALSO NOTE, PLANS WERE ONLY | | | SUBMITTED FOR PLAN REVIEW AND NOT FOR | | | PERMIT APPLICATION. PLEASE NOTE ON PLANS | | | AS OF 7/1/03 WE ARE NOW UNDER THE 2002 | | | NEC. PLEASE ADJUST COVER SHEET. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-08-20 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-08-20 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-08-20 |
Time |
15:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-07-16 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-07-16 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-07-16 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2003-07-16 00:00:00 | 1) INTERIOR FINISH CLASSIFICATION FOR | | | WALLS AND CEILINGS SHALL BE CLASS "A", | | | CLASS "B" OR CLASS "C". | | | | | | 2) SEPARATE SHOP DRAWINGS AND PERMIT | | | APPLICATIONS ARE REQUIRED FOR FIRE ALARM | | | AND FIRE SPRINKLER SYSTEMS REMODEL. | | | | | | 3) PLEASE REF NFPA 101 LIFE SAFETY CODE | | | 2000 EDITION | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-09-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-09 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-09 |
Time |
11:48 |
Sent To |
M |
|
| Notes |
| 2003-09-09 00:00:00 | TO PK DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-07-01 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-01 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-01 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2003-07-01 00:00:00 | COMM BOARD #44 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-09-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-09-12 |
Time |
10:09 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-09-12 |
Time |
10:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2003-08-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-09 |
Time |
11:48 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-08-18 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2003-08-18 00:00:00 | DENIED: | | | 1. PREVIOUS COMMENTS NOT ADDRESSED. | | | | | | - CONDENSATE SHALL NOT DISCHARGE INTO | | | THE SANITARY DRAIN. | | | | | | 2. PROVIDE OUTSIDE AIR CALCULATIONS AS | | | PER 2001 FBC(M) TABLE 403.3 & ASHRAE | | | 62-89. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-07-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-07-09 |
Time |
15:52 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-07-09 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2003-07-09 00:00:00 | DENIED:PLAN CHECK | | | | | | 1.PLAN SHEET MP-1 DETAIL OF THE THRU | | | THE WALL AIR CONDITIONER, NOTE | | | INDICATESCONDENSATE TO DISCHARGE TO | | | NEAREST FLOORDRAIN.AS PER CITY CODE | | | SEC. 90-125 (B), DISCHARGE PROHIBITIONS | | | NO USER SHALL DISCHARGE INTO THE WASTE | | | WATER FACILITY: (5), CONDENSATE. | | | | | | 2.PLEASE CLARIFY FIRE RATING OF | | | WALL BETWEEN THE BATTERY STORAGE AND | | | OFFICE / SALES. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-07-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-09 |
Time |
17:40 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2003-07-09 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2003-07-09 00:00:00 | PASSED/PROVISO - A/C CONDENSATE SHALL | | | NOT DRAIN INTO SANITARY. CITY ORDINANCE | | | #90-125 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2003-09-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-09-12 |
Time |
10:25 |
Rev Time |
0.05 |
| Received By |
pkrauss |
Date |
2003-09-12 |
Time |
10:25 |
Sent To |
|
|
| Notes |
|
|