Plan Review Details - Permit 03062012
Plan Review Stops For Permit 03062012
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-09-08 Cont ID  
Sent By btrobaug Date 2004-01-27 Time 12:04 Rev Time 0.50
Received By lsmith Date 2003-09-08 Time 13:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-07-28 Cont ID  
Sent By kstevens Date 2003-09-06 Time 12:57 Rev Time 3.00
Received By lsmith Date 2003-07-28 Time 09:16 Sent To  
Notes
2003-07-28 00:00:00********BUILDING FAILED************
  
 1. A NOTICE OF COMENCEMENT MUST BE
 FILEDAT COURTHOUSE AND A RECORDED COPY
 SUBMITTED TO THE CITY BEFORE A PERMIT
 CAN BE ISSUED.
 2. PALM BEACH COUNTY IMPACT FEES MUST BE
 PAID AND THE PLANS STAMPED & RETURNED
 TO THE CITY BEFORE A PERMIT CAN BE
 ISSUED
 3. ALL PLANS HAVING AN ARCHITECT
 SEAL ABD SIGNATURE MUST HAVE A TITLE
 BLOCK THAT INCLUDES THE LICENSE NUMBER.
 THIS HAS TO BE ON EVERY PAGE STAMPED &
 SEALED BY THE ARCHITECT.
 4. ADDITIONAL FEES ARE DUE FOR RADON AND
 ADJUSTED VALUE.ALL FEES HAVE TO BE
 PAID BEFORE A PERMIT IS ISSUED.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2004-02-23 Cont ID  
Sent By dpalmer Date 2004-02-23 Time 09:00 Rev Time 0.33
Received By dpalmer Date 2004-02-23 Time 08:25 Sent To  
Notes
2004-02-23 00:00:00REDLINED MISSING EQUIPMENT GRND FROM
 PANEL TO SUB PANEL. 250.122

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2004-01-27 Cont ID  
Sent By csiegber Date 2004-02-17 Time 08:47 Rev Time 0.33
Received By btrobaug Date 2004-01-27 Time 11:43 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-10-28 Cont ID  
Sent By dpalmer Date 2003-10-28 Time 12:01 Rev Time 0.50
Received By dpalmer Date 2003-10-28 Time 12:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2003-10-06 Cont ID  
Sent By csiegber Date 2003-10-24 Time 10:44 Rev Time 0.33
Received By dpalmer Date 2003-10-06 Time 13:46 Sent To  
Notes
2003-10-06 00:00:00***************** UNSAT ****************
  
 1)NOTE: PLEASE SEE MISSING INFORMATION
 REQ'D ON TITLE BLOCK FOR ARCH'S.
 FAC AND FS 61G1-16.004/ 471.
  
 2)NOTE: PLEASE SEE GEN LTS IS SHOWN W/
 60A OCP AND #6 AWG. PLEASE ADJUST.
  
 3)NOTE: THIS IS ONLY A NOTE, PANEL IS
 STILL BEING SHOWN AS MCB, WHICH IS NOT
 REQ'D BUT PERMITTED. PLEASE JUST NOTE,
 IF SHOWN ON PLAN, THEN IT WILL BE REQ'D
 TO BE INSTALLED.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW, IF THERE ARE ANYU QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-08-08 Cont ID  
Sent By csiegber Date 2003-10-02 Time 11:07 Rev Time 0.33
Received By dpalmer Date 2003-08-08 Time 07:27 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-07-08 Cont ID  
Sent By alange Date 2003-08-06 Time 14:55 Rev Time 0.33
Received By dpalmer Date 2003-07-08 Time 07:36 Sent To P
Notes
2003-07-08 00:00:00*************** UNSAT **************
  
 1)NOTE: PLEASE SEE MISSING LICENSE/FIRM
 # REQ'D ON ARCH'S TITLE BLOCK.
 PER FAC/ FS 61G1-16.004
  
 PLEASE SUBMIT THE ABOVE FOR REVIEW. IF
 THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-02-17 Cont ID  
Sent By csiegber Date 2004-02-17 Time 08:47 Rev Time 0.00
Received By csiegber Date 2004-02-17 Time 08:47 Sent To E
Notes
2004-02-17 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-10-24 Cont ID  
Sent By csiegber Date 2003-10-24 Time 10:44 Rev Time 0.00
Received By csiegber Date 2003-10-24 Time 10:44 Sent To E
Notes
2003-10-24 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-10-02 Cont ID  
Sent By csiegber Date 2003-10-02 Time 11:07 Rev Time 0.00
Received By csiegber Date 2003-10-02 Time 11:06 Sent To E
Notes
2003-10-02 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-27 Cont ID  
Sent By dbaxter Date 2003-08-27 Time 16:21 Rev Time 0.00
Received By dbaxter Date 2003-08-27 Time 16:20 Sent To P
Notes
2003-08-27 00:00:00TO KSTEVENS DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-06 Cont ID  
Sent By alange Date 2003-08-06 Time 14:54 Rev Time 0.00
Received By alange Date 2003-08-06 Time 14:54 Sent To E
Notes
2003-08-06 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-06-30 Cont ID  
Sent By mmclean Date 2003-07-03 Time 09:57 Rev Time 0.00
Received By shernand Date 2003-06-30 Time 09:33 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-08-18 Cont ID  
Sent By pkrauss Date 2003-08-18 Time 07:46 Rev Time 0.25
Received By pkrauss Date 2003-08-18 Time 07:45 Sent To B
Notes
2003-08-18 00:00:00APPROVED BY H. MOSER7/15/03 - NO CHANGES

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-07-15 Cont ID  
Sent By kstevens Date 2003-08-15 Time 09:04 Rev Time 0.50
Received By hmoser Date 2003-07-15 Time 18:18 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-09-06 Cont ID  
Sent By kstevens Date 2003-09-06 Time 12:57 Rev Time 0.33
Received By kstevens Date 2003-09-06 Time 12:57 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-08-15 Cont ID  
Sent By dbaxter Date 2003-08-27 Time 16:21 Rev Time 0.50
Received By kstevens Date 2003-08-15 Time 09:04 Sent To M
Notes
2003-08-15 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 AMENDMENTS. CHAPT. 1
  
 1) SANITARY RISER DIAGRAM DOES NOT MEET
 CODE REQUIREMENTS NOR DOES IT REFLECT
 THE FLOOR PLAN.
 A) SANT. RISER SHOWS A SHOWER IN POWDER
 ROOM. FLOOR PLAN SHOWS NO SHOWER.
 B) TUB AND SHOWER IN MASTER BATH NOT
 VENTED PROPERLY. TABLE 906.1
 C) SEE RED LINE CORRECTION SHT A4 FOR
 CORRECT DIAGRAM FOR MASTER BATH. DELETE
 SHOWER AND RESUBMIT. SEC 104.2.1
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-07-15 Cont ID  
Sent By dpalmer Date 2003-08-08 Time 07:27 Rev Time 0.25
Received By jleech Date 2003-07-15 Time 17:50 Sent To M
Notes
2003-07-15 00:00:00LICENSE NUMBER MISSING FROM TITLE BLOCK.

Review Stop Z ZONING
Rev No 1 Status P Date 2003-07-03 Cont ID  
Sent By shernand Date 2003-06-30 Time 09:33 Rev Time 1.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***