Plan Review Details - Permit 03061948
| Plan Review Stops For Permit 03061948 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-07-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-07-05 |
Time |
16:44 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2003-07-05 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2003-07-05 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03061948 | | | ADD: 301 N OLIVE AVE | | | CONT: M. A. C. CONSTRUCTION | | | TEL: (786)357-0214 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | *****BUILDING PROVISO***** | | | | | | 1)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 2)705.7.1 JOINTS INSTALLED IN OR BE- | | | TWEEN FIRE RESISTANT WALLS, FIRE RESIS- | | | TANT FLOORS OR FLOOR/ CEILING ASSEMBLIES | | | AND FIRE RESISTANT ROOFS OR ROOF/ CEIL- | | | ING ASSEMBLIES SHALL BE PROTECTED BY AN | | | APPROVED FIRE RESISTANT JOINT SYSTEM | | | DESIGNED TO RESIST THE PASSAGE OF FIRE | | | FOR A PERIOD NOT LESS THAN THE RE- | | | QUIRED FIRE RESISTANCE RATING OF THE | | | WALL, FLOOR OR FLOOR IN OR BETWEEN | | | WHICH IT IS INSTALLED. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561)6805-6715 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-07-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-07-02 |
Time |
12:35 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-07-02 |
Time |
12:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2003-07-08 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-07-08 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-07-08 |
Time |
12:09 |
Sent To |
|
|
| Notes |
| 2003-07-08 00:00:00 | **************PROVISO******************* | | | INTERIOR WALL AND CEILING FINISH SHALL | | | BE CLASS "A" OR CLASS "B" NFPA 101 CH 39 | | | INTERIOR FINISH. | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-06-27 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-27 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-27 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2003-06-27 00:00:00 | COMM BOARD #10 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-07-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-07-08 |
Time |
12:31 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-07-08 |
Time |
12:31 |
Sent To |
|
|
| Notes |
| 2003-07-08 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR REVIEW | | | PLEASE PROVIDE PLANS WITH MECHANICAL | | | PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
|