| Plan Review Stops For Permit 03061612 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2004-02-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-02-28 |
Time |
16:24 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-02-20 |
Time |
08:12 |
Sent To |
|
|
| Notes |
| 2004-02-28 00:00:00 | REVISION A03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-01-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-02-17 |
Time |
18:38 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-01-17 |
Time |
19:09 |
Sent To |
|
|
| Notes |
| 2004-01-17 00:00:00 | REVISED A03, A07 AS REQUESTED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2003-11-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-14 |
Time |
16:40 |
Rev Time |
1.50 |
| Received By |
sthyng |
Date |
2003-11-12 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2003-11-12 00:00:00 | REVISE SHEETS A03, S02 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2003-11-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-10 |
Time |
14:50 |
Rev Time |
2.00 |
| Received By |
sthyng |
Date |
2003-11-08 |
Time |
17:45 |
Sent To |
|
|
| Notes |
| 2003-11-08 00:00:00 | *****CORRECTIONS***** | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.)SEPARATE PERMITS REQUIRED. | | | | | | 2.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED.A NOTICE OF | | | COMMENCEMENT IS IN THE PACKAGE BUT IT IS | | | INCOMPLETE.IT MUST BE COMPLETED AND | | | FILED WITH THE CLERK OF COURTS. | | | | | | 3.)SEE PREVIOUS LIST, ITEM #3, AND | | | FIRST CORRECTION LIST, ITEM #3.AS | | | DISCUSSED WITH YOU ON THE TELEPHONE, A | | | 34 SINGLE HUNG WINDOW DOES NOT MEET | | | EMERGENCY EGRESS REQUIREMENTS.A COPY | | | OF STANDARD WINDOW SIZES WAS ATTACHED TO | | | THE PREVIOUS LIST (IT IS STILL IN THE | | | PACKAGE) AND I FAXED ONE TO YOU AFTER | | | OUR TELEPHONE CONVERSATION.YOU HAVE | | | CHANGED THE NOTE TO SAY "EH"; UNSURE AS | | | TO WHAT THAT IS.IF YOU FEEL THAT I AM | | | IN ERROR, PROVIDE THE MANUFACTURER'S | | | SPECIFICATION SHOWING THAT A 34 SINGLE | | | HUNG MEETS THE EMERGENCY REQUIREMENTS | | | PER FBC1005.4. | | | | | | 4.)SEE THE PREVIOUS LIST, ITEM 5. | | | A NOTE WAS MADE THAT A WINDOW IN THE | | | MASTER BATH NEEDS TO COMPLY WITH | | | FBC2405.1.THE CORRECTION WAS MADE | | | REFERENCING BATH 2, THE WINDOW AT THE | | | SHOWER.WHEN REVISING THE PLAN, DO NOT | | | QUOTE CODE SECTION. THE PRODUCT APPROVAL | | | SUBMITTED IS FOR IMPACT WINDOWS; THE | | | PLAN CAN INDICATE EITHER SAFETY GLASS, | | | TEMPERED, OR IMPACT, BUT DO NOT | | | REFERENCE CODE SECTION ONLY FBC104.2. | | | | | | 5.)SEE PREVIOUS LIST, ITEM #6.A | | | NOTE WAS ADDED IN REGARDS TO THE LIVE | | | LOAD FOR THE BOTTOM CHORD, BUT #11 OF | | | THE ROOF PLAN NOTES STILL SHOWS THE LIVE | | | LOAD, BOTTOM CHORD AS 5PSF.THIS SHOULD | | | BE 30 FOR ATTICS WITH STORAGE, 10 FOR | | | ATTICS WITHOUT STORAGE. | | | | | | 6.)THE HURRICANE SHUTTER INSTALLATION | | | SCHEDULE IS A FORM TO BE FILLED OUT.A | | | COPY WAS PROVIDED WITH THE LAST REVIEW. | | | A NOTE ON THE PLAN IS NOT NECESSARY, BUT | | | THE FORM DOES NEED TO BE COMPLETED. | | | | | | 7.)PLEASE DO NOT DISSASEMBLE THE | | | PACKAGES I HAVE PUT TOGETHER.THEY HAVE | | | BEEN PUT TOGETHER TO PREPARE THE PACKAGE | | | FOR ISSUANCE; TAKING THE PACKAGES APART | | | DELAYS THE PERMIT PROCESS. | | | | | | 8.)THE SOILS REPORT RECOMMENDS A | | | CONTINUOUS FOUNDATION WIDTH OF AT LEAST | | | 18".REVISE THE FOUNDATION PLAN. | | | | | | 10.)SEE PREVIOUS CORRECTION LIST, ITEM | | | #8.THE PRODUCT APPROVAL SUBMITTED FOR | | | DOORS WAS FOR AN IMPACT FRENCH DOOR WITH | | | SIDELITES.THE FRONT DOOR IS A SERIES | | | OF THREE FRENCH DOORS.THIS IS NOT | | | COVERED BY THE PRODUCT APPROVAL | | | SUBMITTED.THE MULLION PRODUCT APPROVAL | | | SUBMITTED HAS A MAX DESIGN LOAD OF | | | +-35 FOR THAT SIZE.PLEASE NOTE THAT | | | A HEAVY DUTY MULLION HAS A HIGHER DESIGN | | | LOAD.SUBMIT PRODUCT APPROVALS FOR THE | | | MULLION FOR THE FRONT DOOR AND THE | | | FRENCH DOORS (WITHOUT SIDELITES). | | | | | | 11.)THE FRONT DOOR (MAIN EGRESS) IS | | | REQUIED TO HAVE A MINIMUM CLEARANCE OF | | | 32", FBC1012.1.1. | | | | | | WHEN RESUBMITTING, REPLACE SHEETS WHICH | | | HAVE BEEN REVISED AND SUBMIT OLD SHEETS | | | SEPARATELY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-10-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-04 |
Time |
13:56 |
Rev Time |
2.50 |
| Received By |
sthyng |
Date |
2003-10-07 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2003-10-07 00:00:00 | *****CORRECTIONS***** | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SEPARATE PERMITS REQUIRED. | | | | | | 2.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE | | | A PERMIT CAN BE ISSUED. | | | | | | 3.)SEE ATTACHED NOTICE REGARDING | | | FS553.80(2)(B).SEE PREVIOUS CORRECTION | | | LIST #6 - "EXISTING MASTER BEDROOM AND | | | BEDROOM ARE REQUIRED TO HAVE EMERGENCY | | | EGRESS.SPECIFY THE TYPE OF WINDOW, | | | SHOWING COMPLIANCE WITH FBC1005.4." | | | THE CORRECTION ON THE PLAN, A-03, WAS | | | "PROVIDE NEW EGRESS WINDOW IN EXISTING | | | M.O." WITH AN OPENING SIZE OF 37X51. | | | PRODUCT APPROVALS FOR AWNING WINDOWS | | | WERE SUBMITTED.AWNING WINDOWS DO NOT | | | MEET EMERGENCY EGRESS REQUIREMENTS. | | | SINGLE HUNG WINDOWS IN THIS SIZE (SEE | | | ATTACHED) ALSO DO NOT MEET EMERGENCY | | | EGRESS REQUIREMENTS.PLEASE ADDRESS. | | | | | | 4.)THE "NEW GIRDER TRUSS ABOVE DEN" | | | (A03) ATTACHES TO A BEAM ABOVE A WINDOW. | | | IS THIS CORRECT? | | | | | | 5.)THE WINDOW AT THE SHOWER, BATH 2, | | | MUST COMPLY WITH FBC2405.1.SHOW ON THE | | | FLOOR PLAN (A03). | | | | | | 6.)S-02, LIVE LOAD FOR THE BOTTOM | | | CHORD OF THE TRUSSES, ATTIC W/STORAGE | | | SPACE SHOULD BE 30PSF, FBC TABLE 1604.1. | | | | | | 7.)THE PRODUCT APPROVALS FOR THE | | | LOUVERED VENT IS EXPIRED. | | | | | | 8.)NOTE THAT ON PAGE A04 OF THE PLAN, | | | A DESIGN PRESSURE OF +46/-62 IS | | | REQUIRED FOR DOORS AND WINDOWS.THE | | | MAX PRESSURES FOR THE FOLLOWING PRODUCTS | | | DO NOT MEET THE DESIGN PRESSURE | | | REQUIREMENTS AS PER THE PRODUCT | | | APPROVALS: | | | AWNING WINDOWS | | | GARAGE DOOR (+44/-56) | | | MULLIONS (FOR 96X90, +/-35 - FR DOORS) | | | NOTE - MULLIONS OK FOR WINDOWS | | | | | | NOTE - THE IMPACT PRODUCT APPROVALS | | | FOR THE FRENCH DOORS WERE FOR IMPACT | | | DOORS W/SIDELITES.IT APPEARS FROM THE | | | PRODUCT APPROVALS THAT YOU ARE | | | INSTALLING IMPACT AT THE MASTER BEDROOM, | | | NON-IMPACT FRENCH DOORS W/MULLIONS AND | | | SHUTTERS AT THE DINING ROOM (NO SIDELITE | | | SHOWN ON THE FRENCH DOORS AT THAT | | | LOCATION). | | | | | | 9.)PROVIDE A HURRICANE SHUTTER | | | ATTACHMENT SCHEDULE, SEE ATTACHED | | | POLICY. | | | | | | 10.) IF ANY PRODUCT APPROVALS ARE NOT | | | APPROVED AT THE TIME OF ISSUANCE WILL | | | REQUIRE THAT A SEPARATE PERMIT BE | | | APPLIED FOR, WITH ADDITIONAL FEES, FOR | | | THOSE ITEMS. | | | | | | PRODUCT APPROVALS MAY BE AVAILABLE AT | | | WWW.MIAMIDADE.GOV (FIND A DEPT, BUILDING | | | CODE COMPLIANCE, PRODUCT CONTROL, | | | SEARCH APPROVED PRODUCTS). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-07-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-10-02 |
Time |
17:10 |
Rev Time |
3.00 |
| Received By |
sthyng |
Date |
2003-07-16 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2003-07-16 00:00:00 | *******CORRECTIONS******** | | | | | | 1.)SEPARATE PERMITS REQUIRED. | | | | | | 2.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3.)AREA CALCULATIONS SHOULD INCLUDE | | | EXISTING CONDITIONED AND UNCONDITIONED | | | SPACE, PROPOSED, NEW SUBTOTALS AND A | | | NEW TOTAL. | | | | | | 4.)LEGAL DESCRIPTION (A01) SHOULD NOT | | | SAY "RELOCATED".THE CORRECT WORD IS | | | "LOCATED". | | | | | | 5.)THIS IMPROVEMENT IS OVER 25% AND | | | MUST COMPLY WITH FBC 3405 (SEE COMMENTS | | | #6, #7. | | | | | | 6.)EXISTING MASTER BEDROOM AND BEDROOM | | | 2 IS REQUIRED TO HAVE EMERGENCY EGRESS. | | | SPECIFY THE TYPE OF WINDOW, SHOWING | | | COMPLIANCE WITH FBC1005.4. | | | | | | 7.)GLASS AT THE SHOWER MUST COMPLY | | | WITH FBC2405.1. | | | | | | 8.)THE WALL SECTION (3-A05) SPECIFIES | | | R19 INSULATION IN THE CEILING; THE | | | ENERGY CALC REQUIRES A MINIMUM OF R30. | | | | | | 9.)THE NEW GIRDER OVER THE DINING | | | ROOM IS SHOWN AS BEING SUPPORTED BY A | | | COLUMN AT THE ENTRY ON THE FOUNDATION | | | AND ROOF FRAMING PLAN, BUT IS NOT SHOWN | | | ON THE FLOOR PLAN. REVISE. | | | | | | 10.) SPECIFY THE MINIMUM SIZE OF THE | | | ATTIC ACCESS, COMPLYING WITH FBC2309.6 | | | AND FBC2309.7. | | | | | | 11.)SOFFIT VENTS (WALL SECTION 4-A05) | | | CANNOT "MATCH EXISTING"; MUST COMPLY | | | WITH FBC2309.7. | | | | | | 12.)SPECIFY SIZE OF FIRE STOP (4-A05), | | | FBC705.3. | | | | | | 13.)STRUCTURAL NOTE #10 (S01) REFERS | | | TO SOUTH FLORIDA BUILDING CODE.THE | | | GOVERNING CODE IS FLORIDA BUILDING | | | CODE 2001.REVISE. | | | | | | 14.) A CONNECTOR SCHEDULE IS PROVIDED | | | ON S03.THE CONNECTOR MARKS (U2, U4, | | | U5, U8) ARE NOT SHOWN ON THE ROOF | | | FRAMING PLAN (S02). | | | | | | 15.)ROOF SHEATHING SCHEDULE DID NOT | | | PRINT PROPERLY (S02). | | | | | | 16.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE ORIGINAL RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION.233-5025 | | | | | | 17.)SUBMIT PRODUCT APPROVALS FOR ALL | | | EXTERIOR COMPONENTS AND CLADDING, | | | INCLUDING: | | | WINDOW MULLIONS | | | ROOF(MAY BE SUBMITTED WITH ROOF | | | PERMIT) | | | GARAGE DOOR | | | GLASS BLOCK | | | LOUVERED VENT | | | IMPACT PROTECTION | | | WINDOWS | | | FRENCH DOORS | | | SIDELITES | | | | | | 18.)PROVIDE A 2ND COPY OF THE SURVEY. | | | | | | WHEN RESUBMITTING, REPLACE SHEETS WHICH | | | HAVE CHANGED WITH NEW SHEETS (DO NOT | | | REPLACE WITH A NEW PACKAGE UNLESS ALL | | | OF THE SHEETS HAVE CHANGED).SUBMIT | | | THE OLD SHEETS WITH THE PACKAGE. CLEARLY | | | MARK ALL CHANGES. | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-11-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-11-16 |
Time |
07:46 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-11-16 |
Time |
07:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-06-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2004-06-30 |
Time |
09:26 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2004-06-30 |
Time |
09:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-09-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
15:09 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-09-23 |
Time |
10:55 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-07-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-17 |
Time |
16:03 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-07-09 |
Time |
06:56 |
Sent To |
P |
|
| Notes |
| 2003-07-09 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE PROVIDE THE FOLLOWING | | | INFORMATION,MAKE NECESSARY CHANGES TO | | | PLAN AND RESUBMIT FOR REVIEW. | | | | | | 1} PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 2} PLEASE NOTE THAT THE GEC MUST ALSO GO | | | TO FOOTER STEEL PER 250-50(C),IF | | | AVAILABLE. | | | | | | 3} PER 210-11(C)(3),THE RECEPTACLES IN | | | THE MASTER BATH CAN NOT BE ON THE SAME | | | CIRCUIT AS THE GFI IN THE REAR OF THE | | | HOUSE. | | | | | | 4} THE RECEPTACLE IN THE BATHOUTSIDE | | | THE MASTER BEDROOM IS SHOWN ON A CIRCUIT | | | THAT IS LISTED AS A SPARE (A-36),COULD | | | BE ON B-7 PER 210-11(C)(3) AND | | | EXCEPTION. | | | | | | 5} THE EXISTING MASTER BEDROOM IS LISTED | | | ON THE A/C CIRCUIT(A-3),PLEASE CLARIFY. | | | | | | 6} ALL KITCHEN RECEPTACLES THAT SERVE | | | COUNTERTOP SURFACES SHALL BE GFI PER | | | 210-8(A)(6),PLEASE INDICATE SAME ON | | | PLAN. ALSO NOTE SPACING PER | | | 210-52(C)(1).NOTE THEAT THERE WILL BE | | | COUNTERTOP OVER THE DISHWASHER. | | | | | | 7} PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CIRCUITS ON PANEL | | | SCHEDULE OR NOTE ON PLANS FOR BRANCH | | | CIRCUIT PROTECTION. PER 210-12 | | | | | | 8} THE DEN IS CONSIDERED A BEDROOM BY | | | THE FLORIDA BUILDING CODE AND IS | | | THEREFORE REQUIRED TO HAVE A SMOKE | | | DETECTORS PER8-1.4 NFPA-72. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2004-11-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-08 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-08 |
Time |
12:18 |
Sent To |
E |
|
| Notes |
| 2004-11-08 00:00:00 | TO BT DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2004-06-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-25 |
Time |
15:09 |
Sent To |
E |
|
| Notes |
| 2004-06-25 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-02-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-12 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-12 |
Time |
14:35 |
Sent To |
P |
|
| Notes |
| 2004-02-12 00:00:00 | TO KS BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-14 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-14 |
Time |
16:40 |
Sent To |
B |
|
| Notes |
| 2004-01-14 00:00:00 | TO SH DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-11-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-10 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-10 |
Time |
14:50 |
Sent To |
B |
|
| Notes |
| 2003-11-10 00:00:00 | TO ST DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-11-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-04 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-04 |
Time |
13:55 |
Sent To |
B |
|
| Notes |
| 2003-11-04 00:00:00 | TO ST DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-09-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-17 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-17 |
Time |
16:03 |
Sent To |
E |
|
| Notes |
| 2003-09-17 00:00:00 | TO BT DESK RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-06-26 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-26 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-26 |
Time |
10:14 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-06-25 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-23 |
Time |
13:01 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-07-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-09 |
Time |
16:57 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-07-14 |
Time |
07:14 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-02-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-02-17 |
Time |
18:38 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-02-17 |
Time |
18:38 |
Sent To |
B |
|
| Notes |
| 2004-02-17 00:00:00 | REVISION OK - CHANGED FLOOR PLAN LAYOUT | | | IN MASTERBATH - CHANGED RISER DIAGRAM | | | AND FLAT PIPING LAYOUT SHTS P-01 & P-02 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-10-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-12 |
Time |
14:35 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2003-10-02 |
Time |
17:10 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-07-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-09-23 |
Time |
11:23 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-07-09 |
Time |
16:56 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-06-25 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-23 |
Time |
13:01 |
Rev Time |
1.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|