| Plan Review Stops For Permit 03061473 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-07-09 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-07-09 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-07-09 |
Time |
13:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-07-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-07-03 |
Time |
06:35 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-07-03 |
Time |
06:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2003-07-10 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-07-10 |
Time |
10:53 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-07-10 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2003-07-10 00:00:00 | AS PER MIKE CARSILLO |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-01-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-13 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-13 |
Time |
14:19 |
Sent To |
M |
|
| Notes |
| 2004-01-13 00:00:00 | TO PK REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-07-23 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-23 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-23 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2003-07-23 00:00:00 | COMM BD #11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-06-19 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-19 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-19 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2003-06-19 00:00:00 | COMM BOARD #20 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-01-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-21 |
Time |
13:59 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-01-21 |
Time |
13:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-07-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-13 |
Time |
14:19 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-07-26 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2003-07-26 00:00:00 | PROVIDE ADDITIONAL SET OF PLANS. ONLY | | | ONE SET SUBMITTED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-07-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-07-07 |
Time |
10:31 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2003-07-07 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2003-07-07 00:00:00 | DENIED: | | | 1.RETURN AIR GRILLES NOT INDENTIFIED | | | ON PLAN. | | | | | | 2.MATERIALS EXPOSED WITHIN PLENUMS | | | SHALL COMPLY WITH 2001 FBC(M) 602.2.1. | | | | | | 3.PROVIDE OUTSIDE AIR CALCULATIONS AS | | | PER 2001 FBC(M) TABLE 403.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-08-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-05 |
Time |
14:00 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-08-05 |
Time |
14:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-07-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-05 |
Time |
11:19 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-07-05 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2003-07-05 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | | | | 1) SUBMIT DETAIL FOR BREAK ROOM SINK. | | | SHOW COMPLIANCE WITH SECTION 11-4.24 AND | | | ALL SUBSECTIONS. HEIGHT (4.24.2), KNEE | | | CLEARANCE (4.24.3), DEPTH (4.24.4), | | | CLEAR FLOOR SPACE (4.24.5), EXPOSED | | | PIPES ( 4.24.6), & FAUCETS (4.24.7). | | | 2) PROVIDE MANUFACTURE INFORMATION FOR | | | INSTA-HOT WATER HEATER. HEATER SHALL BE | | | LISTED BY APPROVED AGENCY. SEC 303.4 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|