Plan Review Details - Permit 03061190
Plan Review Stops For Permit 03061190
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-07-21 Cont ID  
Sent By lsmith Date 2003-07-21 Time 11:57 Rev Time 0.50
Received By lsmith Date 2003-07-21 Time 11:57 Sent To  
Notes
2003-07-21 00:00:00CORRECTED VALUE, ADD'L FEES DUE; PROCESS
 ED PERMIT 7/21/03 LS

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-07-15 Cont ID  
Sent By pkrauss Date 2003-07-21 Time 08:41 Rev Time 2.50
Received By lhatten Date 2003-07-12 Time 08:22 Sent To  
Notes
2003-07-15 00:00:00REVIEWED & STAMPED PLANS 07/12/2003

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-08-24 Cont ID  
Sent By dpalmer Date 2004-08-24 Time 08:24 Rev Time 0.50
Received By dpalmer Date 2004-08-24 Time 08:24 Sent To  
Notes
2004-08-24 00:00:00************* UNSAT *****************
  
 1)NOTE: PLEASE INCLUDE ALL INFORMATION
 ON TITLE BLOCK AS REQUIRED UNDER FAC
 61G1-16.004 AND PER FS 481.219.
  
 2)NOTE: PLEASE CORRELATE RISER DIAGRAM
 W/ PANELS. RISER SHOWS 200A MLO AND
 PANEL SHOWS 150 MLO.]WHERE IS MAIN?
 PLANS SHOW THERE IS A MAIN NEXT TO
 METER?
 PLEASE SEE "PROVISO " FROM JULY 03,
 PLEASE SHOW LOCATIONS OF ALL SERVICE
 EQUIPMENT.
  
 3)NOTE: PLEASE SEE HANDRAWN CHANGES
 AND WHITE-OUT ON SIGNED AND SEALED
 PLANS. THIS IS NOT PERMITTED UNDER FS
 481.221
  
 4)NOTE: PLEASE SEE OCP AND AWG SHOWN
 FOR A/C HEAT LOADS. PLEASE SEE 424.3
 AND 310.16PLEASE ALSO SEE COND UNIT
 SHOWN AT 7KW W/ 2P15A #10?
  
 5)NOTE: PLEASE CORRELATE LOAD SHOWN ON
 PANEL "B" WITH LOAD SHOWN ON PANEL "A"
 FOR PANEL "B".
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
 \

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-07-09 Cont ID  
Sent By csiegber Date 2004-08-23 Time 08:56 Rev Time 0.33
Received By dpalmer Date 2003-07-09 Time 07:40 Sent To P
Notes
2003-07-09 00:00:00************** PROVISO ************
  
 1)NOTE: PLEASE SHOW SERVICE LOCATION ON
 PLANS .
  
 2)NOTE: PLEASE MOVE SD INTO MASTER
 BEDROOM AREA.
  
 PLEASE SUBMIT THE ABOVE REVISED PLAN
 BEFORE ROUGH ELECTRICAL INSPECTION.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 EELCTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-08-23 Cont ID  
Sent By csiegber Date 2004-08-23 Time 08:56 Rev Time 0.00
Received By csiegber Date 2004-08-23 Time 08:56 Sent To E
Notes
2004-08-23 00:00:00TO DP DESK/REV
 AS BUILTS

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-17 Cont ID  
Sent By shernand Date 2003-07-17 Time 11:28 Rev Time 0.00
Received By shernand Date 2003-07-17 Time 11:28 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-08 Cont ID  
Sent By shernand Date 2003-07-08 Time 10:19 Rev Time 0.00
Received By shernand Date 2003-07-08 Time 10:19 Sent To  
Notes
2003-07-08 00:00:00SUBMITTAL OF PRODUCT APPROVALS ADDED
 TO APPLICATION PACKET ON ELECTRICAL RACK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-06-17 Cont ID  
Sent By mmclean Date 2003-06-19 Time 15:01 Rev Time 0.00
Received By shernand Date 2003-06-17 Time 10:33 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-09-23 Cont ID  
Sent By pkrauss Date 2003-09-23 Time 08:29 Rev Time 0.25
Received By pkrauss Date 2003-09-23 Time 08:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-07-21 Cont ID  
Sent By pkrauss Date 2003-07-21 Time 08:38 Rev Time 0.00
Received By pkrauss Date 2003-07-18 Time 08:38 Sent To B
Notes
2003-07-21 00:00:00PROVISO:
  
 1.PLANS INDICATE MAKE-UP AIR FOR THE
 GARAGE COMING FROM THE HOUSE.MAKE-UP
 AIR FOR GARAGE SHALL COME FROM THE
 OUTDOORS NOT THE RESIDENCE.
  
 2.PROVIDE CALCULATIONS FOR COMBUSTION
 AIR FOR THE LAUNDRY ROOM ON THE JOBSITE
 AT TIME OF INSPECTION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-07-10 Cont ID  
Sent By jleech Date 2003-07-10 Time 16:44 Rev Time 0.50
Received By hmoser Date 2003-07-10 Time 17:27 Sent To B
Notes
2003-07-10 00:00:00PLAN DENIED
 1) NO DUCTSIZE,CFM,OR CAN SIZE ON PLAN
 2) NO ENERGY CALCULATION OR MANUAL (J)
 WITH PLANS
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 2 Status N Date 2003-07-10 Cont ID  
Sent By shernand Date 2003-07-17 Time 11:28 Rev Time 0.25
Received By jleech Date 2003-07-10 Time 16:44 Sent To M
Notes
2003-07-10 00:00:00NO PLUMBING RISER. PLUMBING COMPANY TO
 PROVIDE RISER DIAGRAM WITH PERMIT APP.

Review Stop P PLUMBING
Rev No 1 Status R Date 2003-06-28 Cont ID  
Sent By dpalmer Date 2003-07-09 Time 07:40 Rev Time 0.25
Received By jleech Date 2003-06-28 Time 12:50 Sent To E
Notes
2003-06-28 00:00:00NO RISER DIAGRAM.

Review Stop Z ZONING
Rev No 1 Status P Date 2003-06-19 Cont ID  
Sent By shernand Date 2003-06-17 Time 10:33 Rev Time 1.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***