| Plan Review Stops For Permit 03061181 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-08-21 |
|
|
Cont ID |
|
| Sent By |
lhatten |
Date |
2003-08-21 |
Time |
08:42 |
Rev Time |
1.00 |
| Received By |
lhatten |
Date |
2003-08-20 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2003-08-21 00:00:00 | GOT ALL PRODUCT APPROVALS & DENSITY | | | PAPERS 08/19/2003 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-08-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-16 |
Time |
14:57 |
Rev Time |
3.00 |
| Received By |
lhatten |
Date |
2003-07-27 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2003-08-07 00:00:00 | REVIEWED & STAMPED PLANS 07/27/2003 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-03-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-22 |
Time |
16:06 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-03-22 |
Time |
15:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-08-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-08-15 |
Time |
09:42 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-08-15 |
Time |
09:42 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-07-02 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-15 |
Time |
08:17 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-07-02 |
Time |
06:31 |
Sent To |
M |
|
| Notes |
| 2003-07-02 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~` | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE #2 GROUNDING ELECTRODE CONDUCTOR | | | MUST BE CONTINUOUS PER 250-64(C),REMOVE | | | THE #4. | | | | | | 2} PLEASE SHOW THE LOCATION OF THE | | | SERVICE EQUIPMENT ON THE PLANS. | | | | | | 3} THE HALLWAY OFF THE GARAGE NEEDS A | | | RECEPTACLE TO COMPLY WITH 210.52(H). | | | | | | 4} THE BREAKFAST ROOM,BEDROOM #3, FAMILY | | | ROOM,LIVING ROOM ALL NEED RECEPTACLES | | | ADDED TO COMPLY WITH 210.52(A). | | | | | | 5} THE KITCHEN NEEDS RECEPTACLES TO | | | COMPLY WITH 210.52.(C). | | | | | | | | | 6} BATH ROOM #4 MUST COMPLY WITH | | | 210.52(D). | | | | | | 7} PLEASE NOTE THAT ALL PLANS | | | DRAWN BY AN ARCHITECT/ENGINEER CONTAIN- | | | ING A TITLE BLOCK, MUST BE SIGNED, | | | DATEDAND SEALED BY THE ARCH/ENGINEER OF | | | RECORD. PER FS/FAC 481.221 & 471.025 | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-03-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-23 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-23 |
Time |
09:38 |
Sent To |
P |
|
| Notes |
| 2004-03-23 00:00:00 | TO KS BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-01-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-13 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-13 |
Time |
14:41 |
Sent To |
M |
|
| Notes |
| 2004-01-13 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-09-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-23 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-23 |
Time |
14:39 |
Sent To |
P |
|
| Notes |
| 2003-09-23 00:00:00 | TO KS BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-08-15 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-15 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-15 |
Time |
08:16 |
Sent To |
E |
|
| Notes |
| 2003-08-15 00:00:00 | TO BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-06-25 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-25 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-25 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2003-06-25 00:00:00 | SUBMITTAL FOR MECHANICAL ADDED TO ORIGIN | | | AL APPLICATION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-06-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-06-19 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-17 |
Time |
10:33 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-01-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-23 |
Time |
14:12 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2004-01-23 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-07-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-13 |
Time |
14:41 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-07-06 |
Time |
11:41 |
Sent To |
B |
|
| Notes |
| 2003-07-06 00:00:00 | PROVISO: | | | | | | SUBMIT REVISED PLANS INDICATING MISSING | | | DUCT SIZES PRIOR TO ROUGH INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2004-03-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-24 |
Time |
12:57 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-03-24 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2004-03-24 00:00:00 | REVISION OK - SANT. RISER DIAGRAM |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2003-10-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-23 |
Time |
09:38 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-10-06 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2003-10-06 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SANITARY RISER DIAGRAM DOES NOT RE- | | | FLECT THE FLOOR PLAN. PLEASE SUBMIT A | | | SANT. RISER DIAGRAM THAT REFLECTS THE | | | FLOOR PLAN. 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-08-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-23 |
Time |
14:39 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-08-18 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2003-08-18 00:00:00 | REVISION REQUIRED - LAUNDRY SINK & WASH | | | MACHINE ON DIFFERENT WALLS - SEPARATE | | | STACKS REQUIRED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-08-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-16 |
Time |
14:57 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-08-16 |
Time |
14:57 |
Sent To |
B |
|
| Notes |
| 2003-08-16 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 AMENDMENTS, CHAPTER | | | ONE. | | | | | | 1) COMMENT FROM PREVIOUS REVIEW NOT | | | ADDRESSED. | | | 1) WASH MACHINE AND LAUNDRY SINK ARE | | | NOT ON THE SAME WALL. SEPARATE STACKS | | | ARE REQUIRED. (SEE RED LINE CORRECTIONS | | | WASH MACHINE NOT CALLED OUT ON RISER. | | | A CLEANOUT IS REQUIRED ON W/M STACK 4' | | | ABOVE FLOOR FOR ACCESS.)-MANY PIPE | | | SIZES NOT SHOWN- MANY FIXTURES NOT | | | CALLED OUT ON RISER DIAGRAM. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-06-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-08-15 |
Time |
09:42 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2003-06-28 |
Time |
12:09 |
Sent To |
E |
|
| Notes |
| 2003-06-28 00:00:00 | DENIED; | | | SANITARY RISER DIAGRAM NOT TO CODE. | | | 1.W/M AND L/T ARE NOT ON THE SAME WALL | | | TWO STACKS REQUIRE. | | | 2.BATH TWO, SHR IS NOT VENTED. | | | 3.BIDET IS NOT VENTED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-06-23 |
Time |
15:25 |
Rev Time |
1.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-06-19 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-17 |
Time |
10:33 |
Rev Time |
1.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
| 2003-06-19 00:00:00 | 6/19/03 DENIED, SURVEY DOES NOT MATCH | | | APPLICATION CALL CONT MM |
|
|