Plan Review Details - Permit 03061149
Plan Review Stops For Permit 03061149
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-09-16 Cont ID  
Sent By jwitmer Date 2003-09-16 Time 14:16 Rev Time 0.33
Received By jwitmer Date 2003-09-16 Time 14:16 Sent To  
Notes
2003-09-16 00:00:00REVISION# 3 OKJW

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-08-06 Cont ID  
Sent By btrobaug Date 2003-09-05 Time 16:42 Rev Time 2.00
Received By jwitmer Date 2003-08-06 Time 07:09 Sent To  
Notes
2003-08-06 00:00:00 
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 03061149
 ADDRESS: 10270 TERRA LAGO DRIVE
 CONT: CLASSIC ZUCKERMAN
 TELL # (561)758-4608
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 ******PROVISO**********
  
 SUPPLY PRODUCT APPROVAL FOR THE MULLION
 IN THE GREAT ROOM 192" LONG. PRESSURES
 ARE -32.4/ +29.4 BEFORE BUCK INSPECTION.
  
 1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS SPE
 CIFIED IN THE MATERIALS SECTIONS OF THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23.
  
 RE-EVALUATE TRUSS ANCHOR SCHEDULE BEFORE
 FOOR FRAMING INSPECTION.
 JIM WITMER
 (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-07-28 Cont ID  
Sent By alange Date 2003-08-04 Time 14:36 Rev Time 2.50
Received By jwitmer Date 2003-07-28 Time 13:54 Sent To  
Notes
2003-07-28 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03061149
 ADD: 10270 TERRA LAGO DRIVE
 CONT: CLASSIC ZUCKERMAN
 TEL: (561)758-4608
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 NOTE1803.1.3 EXCAVATION FOR ANY PURPOSE
 SHALL NOT EXTEND WITHIN 1 FT OF THE
 ANGLE OF REPOSE OR NARURAL SLOPE OF THE
 SOIL UNDER ANY FOOTING OR FOUNDATION,
 UNLESS SUCH FOOTING OR FOUNDATION IS
 FIRST PROPERLY UNDERPINNED OR PROTECTED
 AGAINST SETTLEMENT. FOOTING F-5 THE
 CLOSENESS TO POOL.
  
 ACTION: DENIED
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) 1707.4.4.2 TAPERED BUCKS:
 SHALL EXTEND BEYOND THE INTERIOR FACE
 OF THE WINDOW OR DOOR FRAME SUCH THAT
 FULL SUPPORT OF THE FRAME IS SUPPORTED.
  
 3) MULLION SUPPLIED, NOT EVEN MENTIONED
 ON THE CHART TO BEUSED FOR 192".
 COMPONENTS & CLADDING.
  
 4)FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.MISSING SHUTTER ANCHOR SCHEDULE
  
 5)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-03-23 Cont ID  
Sent By btrobaug Date 2004-03-23 Time 16:58 Rev Time 0.50
Received By btrobaug Date 2004-03-23 Time 16:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-09-05 Cont ID  
Sent By csiegber Date 2004-03-23 Time 15:25 Rev Time 0.50
Received By btrobaug Date 2003-09-05 Time 15:55 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-07-02 Cont ID  
Sent By csiegber Date 2003-09-02 Time 11:27 Rev Time 0.50
Received By btrobaug Date 2003-07-02 Time 07:52 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-04-14 Cont ID  
Sent By csiegber Date 2004-04-14 Time 14:53 Rev Time 0.00
Received By csiegber Date 2004-04-14 Time 14:53 Sent To P
Notes
2004-04-14 00:00:00TO KS BOX/REV & FINAL CO DONE SAME DAY

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-03-23 Cont ID  
Sent By csiegber Date 2004-03-23 Time 15:25 Rev Time 0.00
Received By csiegber Date 2004-03-23 Time 15:25 Sent To E
Notes
2004-03-23 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-09-02 Cont ID  
Sent By csiegber Date 2003-09-02 Time 11:27 Rev Time 0.00
Received By csiegber Date 2003-09-02 Time 11:27 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-04 Cont ID  
Sent By alange Date 2003-08-04 Time 14:36 Rev Time 0.00
Received By alange Date 2003-08-04 Time 14:35 Sent To B
Notes
2003-08-04 00:00:00TO JW DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-06-18 Cont ID  
Sent By mmclean Date 2003-06-19 Time 14:53 Rev Time 0.00
Received By shernand Date 2003-06-18 Time 11:06 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-07-06 Cont ID  
Sent By btrobaug Date 2003-07-02 Time 08:32 Rev Time 0.25
Received By pkrauss Date 2003-07-06 Time 11:39 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-04-17 Cont ID  
Sent By kstevens Date 2004-04-17 Time 10:00 Rev Time 1.00
Received By kstevens Date 2004-04-17 Time 10:00 Sent To  
Notes
2004-04-17 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-06-28 Cont ID  
Sent By csiegber Date 2004-04-14 Time 14:53 Rev Time 0.33
Received By jleech Date 2003-06-28 Time 12:19 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-06-19 Cont ID  
Sent By shernand Date 2003-06-18 Time 11:06 Rev Time 1.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***