Plan Review Details - Permit 03061120
Plan Review Stops For Permit 03061120
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-07-29 Cont ID  
Sent By dbaxter Date 2003-08-13 Time 16:35 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2003-07-29 00:00:00THE HAYWARD-BAKER VIBRO FLOTATION SHOP
 DRAWINGS ARE REQUIRED TO BE REVIEWED BY
 THE ENGINEER OF RECORD BEFORE
 SUBMITTING TO THE CITY.
  
 CC DON NEELY

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-07-14 Cont ID  
Sent By alange Date 2003-07-29 Time 10:14 Rev Time 0.00
Received By hpiskura Date 2003-07-14 Time 09:16 Sent To  
Notes
2003-07-14 00:00:00NEEDS IMPACT FEE, NOC AND THRESHOLD
 INSPECTOR

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-07-09 Cont ID  
Sent By shernand Date 2003-07-11 Time 15:10 Rev Time 0.00
Received By hpiskura Date 2003-07-09 Time 09:21 Sent To  
Notes
2003-07-09 00:00:00THIS IS A THRESHOLD BUILDING AND
 REQUIRES A THRESHOLD INSPECTION PLAN,
 THE STATEMENT ON THE PLANS AS CALLED
 OUT IN FS 553 AND AN THESHOLD INSPECTOR
 BEFORE A PERMIT TO CONSTRUCT MAY BE
 ISSUED.SEE FBC 105.13.
  
 SHEET S6 DATED 6/13/03 CALLS OUT
 MISSILEIMPACT PROTECTION TO SSTD 12-97.
 THE FBC INVOKES SSTD 12-99.ALSO,
 SEVERAL OF THE DESIGN STANDARDS CITED
 ARE NOT CURRENT WITH THE FBC.SEE FBC
 3501.
  
 SHEET A1.1 TITLED SITE PLAN DOES NOT
 HAVE ANY DIMENSIONS TO LOCATE THE
 BUILDING ON THE PROPERTY.
  
 SHEET S6 APPEARS TO HAVE FOUNDATIONS IN
 THE PUBLIC RIGHT OF WAY ALONG GRID
 LINES#3 AND #A.PLEASE CLARIFY ON THE
 SITE PLAN THE PRECISE LOCATION OF THE
 BUILDING.

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2003-07-02 Cont ID  
Sent By dpalmer Date 2003-07-02 Time 09:02 Rev Time 0.33
Received By dpalmer Date 2003-07-02 Time 09:02 Sent To  
Notes
2003-07-02 00:00:00*********** NOTE **************
  
 PLEASE SEE NOTE ON PLANS MENTION TO SEE
 ELECTRICAL PLANS?
 NONE SUBMITTED FOR REVIEW AND NO
 ELECTRICAL PERMIT APPLIED FOR AT THIS
 TIME.
 SEPARATE PLANS AND PERMIT REQ`D FOR
 ANY "SLAB" ELECTRICAL WORK.
  
 PLEASE SUBMIT THE ABOVE.
 IF THERE ARE AMY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2003-06-16 Cont ID  
Sent By shernand Date 2003-06-16 Time 13:19 Rev Time 0.50
Received By mamini Date 2003-06-16 Time 13:33 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2003-07-08 Cont ID  
Sent By mcarsill Date 2003-07-08 Time 12:34 Rev Time 0.00
Received By mcarsill Date 2003-07-08 Time 12:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-08-13 Cont ID  
Sent By dbaxter Date 2003-08-13 Time 16:35 Rev Time 0.00
Received By dbaxter Date 2003-08-13 Time 16:34 Sent To B
Notes
2003-08-13 00:00:00TO HPISCURA DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-07-29 Cont ID  
Sent By alange Date 2003-07-29 Time 10:14 Rev Time 0.00
Received By alange Date 2003-07-29 Time 10:14 Sent To B
Notes
2003-07-29 00:00:00TO HP DESK 7/29/03ALANGE

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-11 Cont ID  
Sent By shernand Date 2003-07-11 Time 15:10 Rev Time 0.00
Received By shernand Date 2003-07-11 Time 15:10 Sent To B
Notes
2003-07-11 00:00:00HP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-16 Cont ID  
Sent By mmclean Date 2003-06-27 Time 11:36 Rev Time 0.00
Received By shernand Date 2003-06-16 Time 13:42 Sent To  
Notes
2003-06-16 00:00:00COMM BOARD #2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-06-16 Cont ID  
Sent By shernand Date 2003-06-16 Time 13:19 Rev Time 0.00
Received By shernand Date 2003-06-16 Time 13:19 Sent To ENG
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-07-07 Cont ID  
Sent By pkrauss Date 2003-07-07 Time 07:02 Rev Time 0.10
Received By pkrauss Date 2003-07-07 Time 07:00 Sent To  
Notes
2003-07-07 00:00:00NO MECHANICAL PLANS SUBMITTED FOR
 REVIEW.THIS PERMIT IS FOR FOUNDATION
 PERMIT ONLY.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-07-01 Cont ID  
Sent By kstevens Date 2003-07-01 Time 12:58 Rev Time 1.00
Received By kstevens Date 2003-07-01 Time 12:57 Sent To  
Notes
2003-07-01 00:00:00104.4.5. SPECIAL FOUNDATION PERMIT
 WHEN APPLICATION FOR A PERMIT TO ERECT
 OR ENLARGE A BUILDING HAS BEEN FILED, &
 PENDING ISSURANCE OF SUCH PERMIT, THE
 BUILDING OFFICIAL MAY, AT HIS/ HER
 DISCRETION, ISSUE A SPECIAL PERMIT FOR
 THE FOUNDATION ONLY, UPON WRITTEN RE-
 QUEST OF THE OWNER AND CONTRACTOR. THE
 HOLDER OF SUCH A SPECIAL PERMIT IS PRO-
 CEEDING AT HIS OR HER OWN RISK AND WITH-
 OUT ASSURANCE THAT A PERMIT FOR THE
 REMAINDER OF THE WORK WILL BE GRANTED
 AND THAT CORRECTIONS WILL NOT BE RE-
 QUIRED IN ORDER TO MEET THE PROVISIONS
 OF THE TECHNICAL CODE.

Review Stop Z ZONING
Rev No 1 Status P Date 2003-06-27 Cont ID  
Sent By mmclean Date 2003-06-27 Time 11:36 Rev Time 1.00
Received By mmclean Date   Time   Sent To I
Notes
2003-06-27 00:00:006/27/03 OK PER RANDALL GRANBERRY
 RETURN TO BOX# 2 MM