Plan Review Details - Permit 03061028
| Plan Review Stops For Permit 03061028 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-06-26 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-26 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-26 |
Time |
09:27 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-06-13 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-13 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-13 |
Time |
16:46 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-06-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-27 |
Time |
15:18 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-06-27 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2003-06-27 00:00:00 | | | | | | | | | | | | | PER N. MELICK MANUFACTURE INFO | | | NOT REQUIRED FOR 1 & 2 FAMILY HOMES. | | | JULY 17, 2002 OFFICAL INTERPRETATION. | | | THE FIELD INSPECTOR SHALL VERIFY THE | | | INSTALLED EQUIPMENT INPUT DOES NOT EX- | | | CEED THE PIPE SIZING. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-06-21 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-26 |
Time |
09:27 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-06-21 |
Time |
07:32 |
Sent To |
|
|
| Notes |
| 2003-06-21 00:00:00 | DENIED | | | REFERENCE: FBC-2001 FUEL GAS | | | | | | 1) SECTION 404.3 PLASTIC PIPE, TUBING, & | | | FITTINGS SHALL BE USED OUTSIDE UNDER- | | | GROUND ONLY. | | | 2) SECTION 404.10 VENT REQUIRED FOR | | | SLEEVE. | | | 3. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | 4. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND | | | APPURTENANCES PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
|