| Plan Review Stops For Permit 03060725 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-11-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-11-10 |
Time |
09:29 |
Rev Time |
1.50 |
| Received By |
sthyng |
Date |
2003-11-08 |
Time |
13:35 |
Sent To |
E |
|
| Notes |
| 2003-11-08 00:00:00 | *****CORRECTIONS***** | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.)THE ORIGINAL APPLICATION AND | | | OWNER/BUILDER AFFIDAVIT ARE NO LONGER | | | IN THE PACKAGE.ALL DOCUMENTS ARE TO | | | REMAIN IN THE PACKAGE TO AVOID DELAYS | | | IN PROCESSING THE PERMIT.IF YOU CANNOT | | | FIND THE ORIGINAL APPLICATION, FILL OUT | | | A NEW APPLICATION.THE COPY WILL NOT | | | SUFFICE AS THE SIGNATURE OF THE | | | CONTRACTOR IS ON THE BACK.ALSO FILL | | | OUT A NEW OWNER/BUILDER AFFIDAVIT. | | | | | | 2.)THE NOTICE OF COMMENCEMENT HAS | | | EXPIRED (DID NOT COMMENCE WORK WITHIN | | | 90 DAYS)FS713.13.THE SAME DOCUMENT CAN | | | BE REFILED WITH THE CLERK OF COURTS. | | | | | | 3.)ADDITIONAL PERMITS REQUIRED. | | | | | | 4.)WHEN RESUBMITTING, SUBMIT OLD | | | SHEETS. | | | | | | 5.)SMOKE DETECTORS REQUIRED IN | | | EXISTING HOUSE AS PER FBC3401.7.1.2, | | | FBC905.2.2. | | | | | | 6.)ADDITIONAL FEES DUE (VALUE | | | ADJUSTMENT, RADON), SEE ATTACHED BZ | | | 233264. | | | | | | 7.)THE SOILS REPORT RECOMMENDS | | | CONSTRUCTION JOINTS.HAVE THE | | | STRUCTURAL ENGINEER READ THE SOILS | | | REPORT AND REVISE THE PLAN AS NECESSARY. | | | | | | 8.)THE ELEVATIONS SHOW 3/4" PLYWOOD | | | ROOF SHEATHING; THE DETAILS SHOW 5/8. | | | | | | 9.)THE WINDOW ANCHOR DETAIL IS TO | | | COMPLY WITH FBC1707.4.4.2. | | | | | | 10.) SUBMIT TWO COPIES OF THE SURVEY. | | | ONE IS A PARTIAL COPY TAPED TO THE | | | OTHER AND DOES NOT CONTAIN THE LEGAL | | | DESCRIPTION. | | | | | | 11.) SUBMIT A SECOND COPY OF THE | | | SLIDING GLASS DOOR PRODUCT APPROVAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-06-30 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-11-05 |
Time |
15:25 |
Rev Time |
2.50 |
| Received By |
sthyng |
Date |
2003-06-30 |
Time |
18:24 |
Sent To |
E |
|
| Notes |
| 2003-06-30 00:00:00 | ******CORRECTIONS******* | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)ADDITIONAL PERMITS REQUIRED. | | | | | | 2.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE | | | STAMPED AND THE ORIGINAL RECEIPT | | | ATTACHED TO THE APPLICATION.233-5025 | | | | | | 4.)THE WALL SECTION DOES NOT SHOW | | | INSULATION OR DRYWALL. | | | | | | 5.)THE TYPICAL SAFEGUARD NOTES REFERS | | | TO THE INCORRECT BUILDING CODE. | | | | | | 6.)PROVIDE A SURVEY AND A SITE PLAN | | | FOR THIS JOB.ZONING REVIEW REQUIRED. | | | | | | 7.)FIRESTOP REQUIRED FBC705.3. | | | | | | 8.)AN IMPROVEMENT OF GREATER THAN 25% | | | MUST COMPLY WITH FBC3401.7.1.2.SHOW | | | THE FOLLOWING FOR THE EXISTING HOUSE: | | | FRONT DOOR TO COMPLY WITH FBC 1004. | | | EMERG.EGRESS FOR BEDROOMS, FBC1005.4. | | | BATHROOM TO COMPLY WITH FBC11-11(1) | | | SAFETY GLASS REQUIREMENTS, FBC2405.1. | | | SMOKE DETECTORS TO COMPLY FBC905.2.2. | | | | | | 9.)DETAILS A AND F SHOW 5/8" PLYWOOD, | | | DETAIL D IS 3/4". | | | | | | 10.) FOR THE 2X4 LEDGER, DETAIL F, WHAT | | | IS THE SPACING FOR THE ATTACHMENT? | | | | | | 11.) PROVIDE A DETAIL FOR THE CONCRETE | | | COLUMNS ON THE BALCONY. | | | | | | 12.)ADDITIONAL FEES REQUIRED, $90.30. | | | | | | 13.)PROVIDE A SOILS INVESTIGATION | | | REPORT. | | | | | | 14.)THE LIGHTS ON THE ELEVATIONS ON | | | TOP OF THE CONCRETE COLUMNS ARE NOT ON | | | THE ELECTRIC PLAN. | | | | | | 15.)PROVIDE TWO COPIES OF PRODUCT | | | APPROVALS FOR THE EXTERIOR DOOR. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-11-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-11-10 |
Time |
09:29 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-11-10 |
Time |
09:29 |
Sent To |
B |
|
| Notes |
| 2003-11-10 00:00:00 | | | | PROVISO | | | ~~~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | SEE NOTES FROM THE PREVIOUS REVIEW,NONE | | | WERE ADDRESSED. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-11-10 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-07-01 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-11-08 |
Time |
13:58 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-07-01 |
Time |
14:21 |
Sent To |
M |
|
| Notes |
| 2003-07-01 00:00:00 | PROVISO | | | ~~~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE REVISE PLANS TOREFLECT THE | | | FOLLOWING ADDITIONS FOR CODE COMPLIANCE | | | AND RESUBMIT FOR REVIEW PRIOR TO ANY | | | ELECTRICAL INSPECTIONS. | | | | | | 1} PLEASE NOTE THAT ALL LOW VOLTAGE MUST | | | BE PART OF THE PLAN SUBMITTED IF IT IS | | | TO BE INCLUDED WITH THE PERMIT | | | APPLICATION,OR A SEPERATE PERMIT AND | | | DRAWINGS MUST BE SUBMITTED. | | | | | | 2} A GFI RECEPTACLE MUST BE INSTALLED AT | | | THE REAR OF THE RESIDENCE TO COMPLY | | | WITH 210.52(E). | | | | | | 3} PLEASE NOTE ADDED RECEPTACLES IN THE | | | FAMILY ROOM TO COMPLY WITH 210.52(A). | | | | | | 4} SHOW AN EGRESS LIGHT PER 210.70 AND | | | NOTE HOW SWITCHED. | | | | | | 5} PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CIRCUITS ON PANEL | | | SCHEDULE OR NOTE ON PLANS FOR BRANCH | | | CIRCUIT PROTECTION. PER 210-12 | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-11-10 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-11-18 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-11-10 |
Time |
10:11 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-10-31 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2003-10-31 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2003-10-31 |
Time |
10:59 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-06-17 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-17 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-17 |
Time |
10:19 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-06-11 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-11 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-11 |
Time |
11:24 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-11-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-11-05 |
Time |
15:24 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2003-11-05 |
Time |
15:18 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-07-07 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2003-10-31 |
Time |
10:59 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-07-07 |
Time |
12:36 |
Sent To |
P |
|
| Notes |
| 2003-07-07 00:00:00 | DENIED: | | | | | | ENERGY CALCULATIONS SUBMITTED INDICATE | | | 2920 SQ FT OF CONDITIONED SPACE AND | | | THE EQUIPMENT INDICATES ONLY 2 1/2 TONS | | | OF AIR.PLEASE CLARIFY IF THE 2 1/2 | | | TON UNIT IS FOR THE ENTIRE HOUSE OR IS | | | THERE ANOTHER UNIT THAT IS NOT INDICATED | | | ON PLAN OR ENERGY CALCS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2003-07-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-07-07 |
Time |
12:50 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-07-07 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2003-07-07 00:00:00 | NO PLUMBING PLANS SUBMITTED - NO PLUMB- | | | ING WORK BEING DONE. |
|
|