Plan Review Details - Permit 03060647
Plan Review Stops For Permit 03060647
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-07-29 Cont ID  
Sent By sthyng Date 2003-07-29 Time 15:45 Rev Time 0.50
Received By sthyng Date 2003-07-29 Time 15:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-07-28 Cont ID  
Sent By sthyng Date 2003-07-28 Time 16:53 Rev Time 1.50
Received By sthyng Date 2003-07-28 Time 16:03 Sent To E
Notes
2003-07-28 00:00:00******CORRECTIONS******
  
 1.)THE SITE PLAN DOES NOT MATCH THE
 SURVEY.THE SITE PLAN SHOWS THE WEST
 SIDE OF THE BUILDING AT 5', BUT IT IS
 ACTUALLY 4.8' ACCORDING TO THE SURVEY.
 THE SETBACK IS 5'.
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-07-10 Cont ID  
Sent By pkrauss Date 2003-07-28 Time 09:11 Rev Time 4.00
Received By sthyng Date 2003-07-10 Time 10:25 Sent To  
Notes
2003-07-10 00:00:00******CORRECTIONS*******
  
 1.)SEPARATE PERMITS REQUIRED.
  
 2.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 3.)SIGN THE OWNER/AGENT LINE OF THE
 ENERGY CALC, FBC 13-103.1.2.
  
 4.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE
 STAMPED AND THE ORIGINAL RECEIPT
 ATTACHED TO THE APPLICATION.
  
 5.)GENERAL NOTES, A1, VISQUEEN IS
 REQUIRED TO BE .006 MIN, NOT .004,
 FBC APPENDIX B, 302.
  
 6.)1 1/2" WATERSTOP IS REQUIRED, NOT
 3/4" AS SHOWN ON THE PLAN, CITY OF
 WEST PALM BEACH AMENDMENTS TO THE FBC,
 2111.1.9.REVISE ALL AFFECTED NOTES,
 INCLUDING 3-A2, FOUNDATION NOTE #12 A2,
 1-A4, 2-A4.
  
 7.)THE FOOTING IS REQUIRED TO BE 4"
 MIN. ABOVE GRADE, 12" MIN. BELOW GRADE
 (FBC1804.1.3 AND CITY OF WPB AMENDMENTS
 TO THE FBC 1804.1.7).REVISE ALL
 AFFECTED NOTES AND DETAILS, INCLUDING
 3-A2, 1-A2, 1-A4, 2-A4.
  
 8.)REVISE THE PERMIT APPLICATION TO
 REFLECT THE SCOPE OF WORK.IT NOW SAYS
 ONLY "DEMO INTERIOR".
  
 9.) HAVE THE DESIGNER READ THE SOILS
 REPORT PROVIDED WITH THIS PERMIT
 APPLICATION.
  
 A.) THE PLANS REFER TO "VIBRO
 COMPACTED" TO PREPARE THE SOIL.THIS
 IS IN CONFLICT WITH THE SOILS REPORT.
 REVISE ALL NOTES AND DETAILS, INCLUDING
 FOUNDATION NOTE #2 A2, 3-A2, GENERAL
 NOTEA1.
  
 B.) PRESSURE GROUTING OF THE EXISTING
 AND PROPOSED FOUNDATIONS ARE REQUIRED.
 MAKE A NOTE ON THE PLAN.
  
 10.)THE 24 SINGLE HUNG WINDOWS DO NOT
 COMPLY WITH FBC1005.4.
  
 11.)THE 2'6 DOOR (BATHROOM) DOES NOT
 COMPLY WITH FBC 11-11 (2'8" MINIMUM).
  
 12.)THE AREA CALCS, A1, SHOULD SHOW
 EXISTING CONDITIONED AND UNCONDITIONED
 SPACE, PROPOSED NEW, AND TOTALS.
  
 13.)PROVIDE A SURVEY FOR THIS JOB.
  
 14.)WIND INFILTRATION, A5, INTERNAL
 PRESSURE COEFFICIENT IS SHOWN AS 1.0.
 IS THIS NUMBER CORRECT?ALSO GIVE THE
 APPLICABLE ENCLOSURE CLASSIFICATION
 FBC1606.1.7.
  
 15.)THE TEXT FOR 1005.4, A5, APPEARS
 TO BE FROM A CODE OTHER THAN FBC. EITHER
 MAKE THE TEXT CONSISTENT WITH THE
 CURRENT BUILDING CODE OR REMOVE IT FROM
 THE PLAN.
  
 16.)IMPACT PROTECTION IS REQUIRED FOR
 THE GLAZED DOOR, FBC 1606.1.4.PROVIDE
 TWO COPIES OF PRODUCT APPROVALS.
  
 17.)THE FOOTING WIDTH SHOULD BE A
 MINIMUM OF 18" PER THE SOILS REPORT.
 REVISE ALL NOTES AND DETAILS, INCLUDING
 1-A2, 3-A2, 1-A4, 2-A4.
  
 18.)SUBMIT PRODUCT APPROVALS FOR:
 MULLIONS
 SINGLE HUNG WINDOW (PAS SUBMITTED
 WERE ILLEGIBLE)
 IMPACT PROTECTION FOR THE DOOR
 ROOF SHINGLES (MAY BE SUBMITTED NOW
 OR WITH ROOF PERMIT APPLICATION)
 LOUVERED GABLE VENT
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-06-23 Cont ID  
Sent By sthyng Date 2003-07-28 Time 17:05 Rev Time 0.50
Received By btrobaug Date 2003-06-23 Time 14:16 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-07-18 Cont ID  
Sent By shernand Date 2003-07-18 Time 14:23 Rev Time 0.00
Received By shernand Date 2003-07-18 Time 14:22 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-06-26 Cont ID  
Sent By shernand Date 2003-06-26 Time 15:53 Rev Time 0.00
Received By shernand Date 2003-06-26 Time 15:53 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-06-20 Cont ID  
Sent By shernand Date 2003-06-19 Time 16:58 Rev Time 0.00
Received By shernand Date 2003-06-20 Time 09:57 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-18 Cont ID  
Sent By mmclean Date 2003-06-19 Time 12:27 Rev Time 0.00
Received By shernand Date 2003-06-18 Time 08:18 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-06-11 Cont ID  
Sent By shernand Date 2003-06-11 Time 11:38 Rev Time 0.00
Received By shernand Date 2003-06-11 Time 11:38 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-07-28 Cont ID  
Sent By pkrauss Date 2003-07-28 Time 09:08 Rev Time 0.35
Received By pkrauss Date 2003-07-28 Time 09:08 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-07-07 Cont ID  
Sent By kstevens Date 2003-07-24 Time 17:57 Rev Time 0.25
Received By pkrauss Date 2003-07-07 Time 09:04 Sent To B
Notes
2003-07-07 00:00:00DENIED:MECHANICAL PERMIT 03060753
  
 SEE COMMENTS UNDER MECHANICAL PERMIT #.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-07-24 Cont ID  
Sent By kstevens Date 2003-07-24 Time 17:57 Rev Time 0.33
Received By kstevens Date 2003-07-24 Time 17:57 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-06-23 Cont ID  
Sent By shernand Date 2003-07-18 Time 14:23 Rev Time 0.50
Received By kstevens Date 2003-06-23 Time 18:25 Sent To B
Notes
2003-06-23 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT THE FLOOR PLAN OR MEET CODE RE-
 QUIREMENTS. PLEASE SEE ATTACHED SHEET
 FOR EXAMPLE OF RISER DIAGRAM THAT MEETS
 CODE REQUIREMENTS AND FLOOR PLAN.
 SEC 802.4 - 1002.1 - 104.2.1
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop Z ZONING
Rev No 2 Status P Date 2003-06-19 Cont ID  
Sent By mmclean Date 2003-06-19 Time 12:26 Rev Time 1.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2003-06-12 Cont ID  
Sent By shernand Date 2003-06-18 Time 08:18 Rev Time 1.00
Received By mmclean Date   Time   Sent To  
Notes
2003-06-12 00:00:006/12/03 DENIED, TOO MUCH CONCRETE IN
 FRONT YARD/REDUCE WIDTH TO 12" DW WILL
 BE OK MM