Plan Review Details - Permit 03060557
Plan Review Stops For Permit 03060557
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-07-22 Cont ID  
Sent By sthyng Date 2003-07-22 Time 14:23 Rev Time 2.00
Received By sthyng Date 2003-07-22 Time 14:23 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-06-30 Cont ID  
Sent By btrobaug Date 2003-07-21 Time 17:46 Rev Time 2.50
Received By sthyng Date 2003-06-30 Time 14:46 Sent To  
Notes
2003-06-30 00:00:00******CORRECTIONS******
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)ADDITIONAL PERMITS REQUIRED.
  
 2.)SIGN OWNER/AGENT LINE OF ENERGY
 CALC FBC13-103.1.2.
  
 3.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 4.)ADDITIONS OF OVER 25% MUST COMPLY
 WITH FBC 3401.7.1.2.THE STRUCTURAL
 PERMIT WILL BE ISSUED WITH A PROVISO
 THAT: (A) THERE IS A BATHROOM TO COMPLY
 WITH FBC11-4.22.2, AND (B) SMOKE
 DETECTORS IN EXISTING BEDROOMS FBC905.2.
 2.
  
 5.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE
 STAMPED AND THE ORIGINAL RECEIPT
 ATTACHED TO THE APPLICATION.
  
 6.)ADDITIONAL FEES DUE, $77.90.
  
 7.)SOILS INVESTIGATION REPORT
 REQUIRED.
  
 8.)IMPACT PROTECTION FOR GLAZING
 IS REQUIRED FOR THE FRENCH DOORS.
 PRODUCT APPROVALS SUBMITTED MUST BE
 FOR IMPACT GLASS OR SUBMIT PRODUCT
 APPROVALS FOR SHUTTERS.
  
 9.) SUBMIT TWO LEGIBLE PRODUCT APPROVALS
 FOR THE FOLLOWING:
 FRENCH DOORS
 SIDE LITES
 MULLIONS
 IMPACT PROTECTION
 CASEMENT WINDOWS, IMPACT
 ROOF SHINGLES

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-07-21 Cont ID  
Sent By btrobaug Date 2003-07-21 Time 17:45 Rev Time 0.50
Received By btrobaug Date 2003-07-21 Time 15:19 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-06-17 Cont ID  
Sent By kstevens Date 2003-07-19 Time 09:51 Rev Time 0.50
Received By dpalmer Date 2003-06-17 Time 14:30 Sent To P
Notes
2003-06-17 00:00:00************NOTES REDLINED ********
  
 PLEASE SEE OCP FOR AHU , 5KW W/ 1-P 50A
 BRKR.
 PLEASE SEE REQ`D DEDICATED BATH CIRCUIT
 (S) TO BE 20A, #12. 210-52D/210-11C3
 PLEASE SEE MISSING SD OUTSIDE BEDROOM.
 NFPA-72
 PLEASE SEE MISSING RECEPT W/ IN 6' OF
 DOORS. 210-52
  
 THE ABOVE HAS BEEN REDLINED ON PLANS.
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-17 Cont ID  
Sent By shernand Date 2003-07-17 Time 13:33 Rev Time 0.00
Received By shernand Date 2003-07-17 Time 13:33 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-13 Cont ID  
Sent By shernand Date 2003-06-13 Time 09:22 Rev Time 0.00
Received By shernand Date 2003-06-13 Time 09:22 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-06-10 Cont ID  
Sent By mmclean Date 2003-06-13 Time 09:01 Rev Time 0.00
Received By shernand Date 2003-06-10 Time 16:44 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-06-19 Cont ID  
Sent By kstevens Date 2003-06-19 Time 08:15 Rev Time 0.25
Received By pkrauss Date 2003-06-19 Time 10:02 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-07-19 Cont ID  
Sent By kstevens Date 2003-07-19 Time 09:51 Rev Time 0.50
Received By kstevens Date 2003-07-19 Time 09:51 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-06-19 Cont ID  
Sent By shernand Date 2003-07-17 Time 13:33 Rev Time 0.50
Received By kstevens Date 2003-06-18 Time 18:35 Sent To M
Notes
2003-06-18 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SHT M-1 PLUMBING NOTES: #1, CODE IN
 EFFECT IS FBC-2001 PLUMBING NOT THE
 STANDARD CODE. PLEASE CHANGE REFERENCE.
 2) SHT M-1 PLUMBING NOTES : #11, AIR
 CHAMBERS ARE NOT APPROVED. PLEASE DELETE
 THEM FROM REFERENCE. 104.2.1
 3) SHT M-1 PLUMBING NOTES: #15, SEPARATE
 PERMIT AND PLANS REQUIRED FOR GAS. SEE
 ATTACHED SHEET FOR GAS PERMIT APPLICAT-
 ION REQUIREMENTS.
 4) SHT M-1 SANITARY RISER DIAGRAM DOES
 NOT REFLECT THE FLOOR PLAN OR MEET CODE
 REQUIREMENTS. LAUNDRY SINK AND WASH
 MACHINE ARE SHOWN ON FLOOR PLAN BUT NOT
 SHOWN ON RISER DIAGRAM. WASH MACHINE
 WILL REQUIRE A STAND PIPE AND BE ON SEP-
 ARATE STACK FROM LAUNDRY SINK. (SEPARATE
 WALLS) SECTION 802.4. DOUBLE SANITARY
 TEE PATERNS SHALL NOT RECIEVE THE DIS-
 CHARGE OF APPLIANCES WITH PUMPING ACTION
 DISCHARGE. SECTION 706.3. ONLY ONE LAV
 SHOWN ON RISER AND THERE ARE 2 SHOWN ON
 THE FLOOR PLAN.
 (SEE ATTACHED SHEET FOR RISER DIAGRAM
 THAT REFLECTS THE FLOOR PLAN AND MEETS
 THE CODE REQUIREMENTS.
 5) ARCHITECT'S ADDRESS AND PHONE # ARE
 REQUIRED ON TITLE BLOCK PER 61G1-16.004.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop Z ZONING
Rev No 1 Status P Date 2003-06-13 Cont ID  
Sent By shernand Date 2003-06-10 Time 16:44 Rev Time 1.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***