Plan Review Details - Permit 03060557
| Plan Review Stops For Permit 03060557 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-07-22 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-07-22 |
Time |
14:23 |
Rev Time |
2.00 |
| Received By |
sthyng |
Date |
2003-07-22 |
Time |
14:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-06-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-07-21 |
Time |
17:46 |
Rev Time |
2.50 |
| Received By |
sthyng |
Date |
2003-06-30 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2003-06-30 00:00:00 | ******CORRECTIONS****** | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)ADDITIONAL PERMITS REQUIRED. | | | | | | 2.)SIGN OWNER/AGENT LINE OF ENERGY | | | CALC FBC13-103.1.2. | | | | | | 3.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 4.)ADDITIONS OF OVER 25% MUST COMPLY | | | WITH FBC 3401.7.1.2.THE STRUCTURAL | | | PERMIT WILL BE ISSUED WITH A PROVISO | | | THAT: (A) THERE IS A BATHROOM TO COMPLY | | | WITH FBC11-4.22.2, AND (B) SMOKE | | | DETECTORS IN EXISTING BEDROOMS FBC905.2. | | | 2. | | | | | | 5.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE | | | STAMPED AND THE ORIGINAL RECEIPT | | | ATTACHED TO THE APPLICATION. | | | | | | 6.)ADDITIONAL FEES DUE, $77.90. | | | | | | 7.)SOILS INVESTIGATION REPORT | | | REQUIRED. | | | | | | 8.)IMPACT PROTECTION FOR GLAZING | | | IS REQUIRED FOR THE FRENCH DOORS. | | | PRODUCT APPROVALS SUBMITTED MUST BE | | | FOR IMPACT GLASS OR SUBMIT PRODUCT | | | APPROVALS FOR SHUTTERS. | | | | | | 9.) SUBMIT TWO LEGIBLE PRODUCT APPROVALS | | | FOR THE FOLLOWING: | | | FRENCH DOORS | | | SIDE LITES | | | MULLIONS | | | IMPACT PROTECTION | | | CASEMENT WINDOWS, IMPACT | | | ROOF SHINGLES |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-07-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-07-21 |
Time |
17:45 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-07-21 |
Time |
15:19 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-06-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-19 |
Time |
09:51 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-06-17 |
Time |
14:30 |
Sent To |
P |
|
| Notes |
| 2003-06-17 00:00:00 | ************NOTES REDLINED ******** | | | | | | PLEASE SEE OCP FOR AHU , 5KW W/ 1-P 50A | | | BRKR. | | | PLEASE SEE REQ`D DEDICATED BATH CIRCUIT | | | (S) TO BE 20A, #12. 210-52D/210-11C3 | | | PLEASE SEE MISSING SD OUTSIDE BEDROOM. | | | NFPA-72 | | | PLEASE SEE MISSING RECEPT W/ IN 6' OF | | | DOORS. 210-52 | | | | | | THE ABOVE HAS BEEN REDLINED ON PLANS. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-07-17 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-17 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-17 |
Time |
13:33 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-06-13 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-13 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-13 |
Time |
09:22 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-06-10 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-06-13 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-10 |
Time |
16:44 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-06-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-19 |
Time |
08:15 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-06-19 |
Time |
10:02 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-07-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-19 |
Time |
09:51 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-07-19 |
Time |
09:51 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-06-19 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-17 |
Time |
13:33 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-06-18 |
Time |
18:35 |
Sent To |
M |
|
| Notes |
| 2003-06-18 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHT M-1 PLUMBING NOTES: #1, CODE IN | | | EFFECT IS FBC-2001 PLUMBING NOT THE | | | STANDARD CODE. PLEASE CHANGE REFERENCE. | | | 2) SHT M-1 PLUMBING NOTES : #11, AIR | | | CHAMBERS ARE NOT APPROVED. PLEASE DELETE | | | THEM FROM REFERENCE. 104.2.1 | | | 3) SHT M-1 PLUMBING NOTES: #15, SEPARATE | | | PERMIT AND PLANS REQUIRED FOR GAS. SEE | | | ATTACHED SHEET FOR GAS PERMIT APPLICAT- | | | ION REQUIREMENTS. | | | 4) SHT M-1 SANITARY RISER DIAGRAM DOES | | | NOT REFLECT THE FLOOR PLAN OR MEET CODE | | | REQUIREMENTS. LAUNDRY SINK AND WASH | | | MACHINE ARE SHOWN ON FLOOR PLAN BUT NOT | | | SHOWN ON RISER DIAGRAM. WASH MACHINE | | | WILL REQUIRE A STAND PIPE AND BE ON SEP- | | | ARATE STACK FROM LAUNDRY SINK. (SEPARATE | | | WALLS) SECTION 802.4. DOUBLE SANITARY | | | TEE PATERNS SHALL NOT RECIEVE THE DIS- | | | CHARGE OF APPLIANCES WITH PUMPING ACTION | | | DISCHARGE. SECTION 706.3. ONLY ONE LAV | | | SHOWN ON RISER AND THERE ARE 2 SHOWN ON | | | THE FLOOR PLAN. | | | (SEE ATTACHED SHEET FOR RISER DIAGRAM | | | THAT REFLECTS THE FLOOR PLAN AND MEETS | | | THE CODE REQUIREMENTS. | | | 5) ARCHITECT'S ADDRESS AND PHONE # ARE | | | REQUIRED ON TITLE BLOCK PER 61G1-16.004. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-06-13 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-10 |
Time |
16:44 |
Rev Time |
1.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
|