| Plan Review Stops For Permit 03060449 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-05-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-05-10 |
Time |
16:09 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
2004-05-10 |
Time |
16:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2004-04-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-04-23 |
Time |
11:07 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2004-04-23 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2004-04-23 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03060449 | | | ADD: 622 N FLAGLER (MARINA) | | | CONT:T B A | | | CONTACT: GEORGE TIBEDO | | | TEL: (561)902-7204 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | ACTION: PENDING | | | | | | 1) NO CONTRACTOR, PLAN REVIEW ONLY, | | | CONTRACTOR TO SUBMIT FOR PERMIT! | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-02-03 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-02-03 |
Time |
08:52 |
Rev Time |
2.50 |
| Received By |
jwitmer |
Date |
2004-02-02 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2004-02-03 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03060449 | | | ADD: 622 N FLAGLER DR | | | CONT: (PLAN REVIEW)GEORGE TIBEDO | | | TEL: (561)758-5995 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | THIRD REVIEW | | | ACTION: DENIED | | | | | | 1) CITY CODE 94-378 (1) ALL NEW MARINAS | | | SHALL HAVE WRITTEN APPROVAL FROM THE | | | U.S. ARMY CORP OF ENGINEERS, STATE DE- | | | PARTMENT OF ENVIROMENTAL REGULATIONS, | | | STATE DEPARTMENT OF NATURAL RESOURCES, | | | BOARD OF TRUSTESS OF THE INTERNAL IMPROV | | | MENT TRUST FUND AND THE SOUTH FLORIDA | | | WATER DISTRICT. | | | | | | BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. $7,822.21 FOR A 22 SLIP | | | MARINA. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-10-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-10-30 |
Time |
15:10 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2003-10-30 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2003-10-30 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03060449 | | | ADD: 622 N FLAGLER DR | | | CONT: PLAN REVIEW | | | TEL: (561)630-4284 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) CITY CODE 94-378 (1) ALL NEW MARINAS | | | SHALL HAVE WRITTEN APPROVAL FROM THE | | | U. S. ARMY CORP OF ENGINEERS, STATE DE- | | | PARTMENT OF ENVIROMENTAL REGULATIONS, | | | STATE DEPARTMENT OF NATURAL RESOURCES, | | | BOARD OF TRUSTEES OF THE INTERNALIMPRO | | | VEMENT TRUST FUND, AND THE SOUTH | | | FLORIDA WATER DISTRICT. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-07-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-07-05 |
Time |
13:18 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
2003-07-05 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2003-07-05 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03060449 | | | ADD: 622 N FLAGLER DR | | | CONT: PLAN REVIEW | | | CONTACT: COMMUNITIES FINANCE CORP | | | TEL: (561)630-4284 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | ACTION : DENIED | | | | | | 1) CITY CODE: 94-378(1) ALL NEW MARINAS | | | SHALL HAVE WRITTEN APPROVAL FROM THE | | | U.S. ARMY CORP OF ENGINEERS, STATE DERT. | | | OFENVIROMENTAL REGULATIONS,STATE DEPART- | | | MENT OF NATURAL RESOURCES, BOARD OF | | | TRUSTEES OF THE INTERNAL IMPROVEMENT | | | TRUST FUND, AND THE SOUTH FLORIDA WATER | | | MANAGEMENT DISTRICT. | | | | | | 2) PROJECT LOCATED IN A FLOOD ZONE A5 | | | BASE FLOOD ELEVATION 7'-0", CITY FLOOD | | | ZONE REQUIREMENT OF 7'-6" FINISH FLOOR, | | | THE QUESTION TO DETERMINED IF THIS IS IN | | | A FLOODWAY WITH MORE RESTRICTIVE REQUIRE | | | MENTS. | | | | | | 3) 1015.1 GUARDRAILS: GUARDRAILS ARE | | | REQUIRED ON THE DOCKS WITH THE EXCEPTION | | | #1, NOT ON THE LOADING SIDE OF DOCK. | | | | | | 4)1015.2 HEIGHT. GUARDRAILS SHALL | | | FORM A VERTICAL PROTECTIVE BARRIER NOT | | | LESS THAN 42" HIGH. | | | 1015.3 OPENINGS. OPEN GUARDRAILS | | | SHALL HAVE INTERMEDIATE RAILS OR ORNA- | | | MENTAL PATTERNS SUCH AS A 4" DIAMETER | | | SPHERE CAN NOT PASS THROUGH. A BOTTOM | | | RAIL OR CURB SHALL BE PROVIDED THAT WILL | | | REJECT THE PASSAGE OF 2" DIAMETER | | | SPHERE. | | | | | | 5) FAIR HOUSING ACT, COMMON AREAS: WHEEL | | | CHAIR ACCESSIBLITY WITH WOOD LAY IN SEC- | | | TION, IS THERE SPACES BETWEEN PLANKS NOT | | | ALLOWING WHEELCHAIR ACCESSIBILITY? | | | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | JIM WITMER | | | BUILDING PLAN REVIEW | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-10-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-27 |
Time |
07:17 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-10-27 |
Time |
07:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-06-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-06-26 |
Time |
12:46 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2003-06-26 |
Time |
12:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2004-04-21 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-04-21 |
Time |
13:43 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-04-21 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2003-10-23 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-10-23 |
Time |
15:19 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-10-23 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2003-10-23 00:00:00 | FAILED: | | | 1. PLEASE REFER TO COMMENT NO. ONE | | | IN PREVIOUS REVIEW DATED 6-18-03, STATED | | | THAT, CONSTRUCTION OF THIS FACILITIES | | | MUST BE APPROVED BY THE U.S. ARMY CORP | | | OF ENGINEERS,STATE DEPARTMENT OF NATURAL | | | RERESOURCES, STATE DEPARTMENT OF | | | ENVIRONMENTAL REGULTION, BORAD OF | | | TRUSTEES OF THE INTERNAL IMPROVEMENT | | | TRUST FOUD, AND THE SOUTH FLORIDA WATER | | | MANAGEMENT DISTRICT. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2003-06-18 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-06-18 |
Time |
13:59 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-06-18 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2003-06-18 00:00:00 | FAILED: | | | 1. PLAESE SUBMIT A COPY OF PEMITS FROM | | | THE U.S. CORP OF ENGINEERS, SOUTH | | | FLORIDA WTAER MANAGEMENT DISTRICT, STATE | | | DEPARTMENT OF ENVIRONMENTAL REGULATION, | | | STATE DEPARTMENT OF NATURAL RESOURCES | | | AND OTHER STATE PERMITTING AGENCIES. | | | 2. PLEASE NOTE THAT PILE DRIVING | | | OPERATION MUST OCCUR BETWEEN THE HOURS | | | OF 7:00 AM AND 7:00 PM MONDAY THROUGH | | | FRIDAY; BETWEEN THE HOURS OF 8:00 AM AND | | | 8:00 PM SATERDAY AND SUNDAY. | | | 3. LIFE SAFETY FLOTATION DEVICES THROUGH | | | OUT THE DOCKING AREA SHOULD BE PROVIDED. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-11-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-11-04 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-11-04 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2003-11-04 00:00:00 | 1) NO SMOKING SIGNS WILL BE REQUIRED. | | | | | | 2) ALL FIREFIGHTING EQUIPMENT SHALL BE | | | TESTED AND MAINTAINED. | | | | | | 3) FULL COMPLIANCE WITH NFPA 303, THE | | | FIRE PROTECTION STANDARD FOR MARINAS | | | AND BOATYARDS. | | | | | | 4) A MEANS SHALL BE PROVIDED FOR | | | PERSONS TO NOTIFY THE FIRE DEPARTMENT | | | IN THE EVENT OF AN EMERGENCY. | | | | | | 5) ONLY LISTED NONFERROUS PIPING SHALL | | | BE USED. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2003-07-07 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-07-07 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-07-07 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2003-07-07 00:00:00 | *************PROVISO******************** | | | PLEASE REF NFPA 101 LIFE SAFETY CODE | | | 2000 EDITION CHAPTER 11.5 AND NFPA 307 | | | 2000 EDITION. | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-04-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-20 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-20 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2004-04-20 00:00:00 | TO COMM BD#59 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-10-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-20 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-20 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2003-10-20 00:00:00 | TO COMM BD#38 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-06-16 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-16 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-16 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2003-06-16 00:00:00 | COMM BOARD #16 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-06-06 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-06 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-06 |
Time |
11:46 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-07-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-07-03 |
Time |
06:58 |
Rev Time |
0.10 |
| Received By |
pkrauss |
Date |
2003-07-03 |
Time |
06:56 |
Sent To |
|
|
| Notes |
| 2003-07-03 00:00:00 | NO MECHANICAL - THIS PERMIT IS FOR | | | DOCKS AT ONE WATERMARK. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-01-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-10 |
Time |
13:20 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2004-01-10 |
Time |
13:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-11-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-11-06 |
Time |
09:13 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2003-11-06 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2003-11-06 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA STATUTES | | | FLORIDA ADMINISTRATIVE CODE | | | | | | A) COMMENTS FROM PREVIOUS RESPONSE NOTED | | | BUT A CLAIRFICATION OF COMMENTS NEEDED. | | | 1) A SEPARATE BACKFLOW IS REQUIRED FOR | | | THE MARINA WATER SERVICE LINE. SECTION | | | 608.13.2 | | | 2) MANUFACTURE SPECIFICATION SHEETS TO | | | BE SUBMITTED FOR REVIEW FOR THE PUMP-OUT | | | SYSTEM. SECTION 104.3.1 | | | 3) MANUFACTURE SPECIFICATION SHEETS TO | | | BE SUBMITTED FOR REVIEW FOR THE UTILITY | | | PEDESTALS, (DETAIL #14). SECTION 104.3.1 | | | 4) NEW COMMENT: ENGINEERS SHALL LEGIBLY | | | THEIR NAME, ADDRESS AND LICENSE NUMBER | | | ON EACH SHEET. IF PRACTICING THROUGH A | | | DULY AUTHORIZED ENGINEERING BUSINESS, | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME AND LICENSE NUMBER, AS WELL AS, THE | | | NAME, ADDRESS, AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. 61G15-23.002(2) | | | FS471.025 - (SEE ATTACHED SHEET). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-06-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-27 |
Time |
11:19 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-06-27 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2003-06-27 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | | | | | | | 1) SHT C3 OF 5 - RPZ BACKFLOW REQUIRED | | | SECTION 608.13.2 | | | 2) SHT C3 OF 5 AND SHT C5 OF 5 MANUF. | | | INFORMATION REQUIRED FOR PUMP-OUT SYSTEM | | | 3) SHT C3 OF 5 MANUF. INFORMATION REQ- | | | UIRED FOR UTILITY PEDESTALS, (DETAIL #4) | | | 4) ALL PVC EXPOSED TO ULTRA VIOLET RAYS | | | SHALL BE PROTECTED BY PAINTING WITH | | | APPROVED U.V. BLOCKING PAINT PER MANUF. | | | INSTALLATION REQUIREMENTS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-02-03 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-02-03 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-02-03 |
Time |
08:51 |
Sent To |
B |
|
| Notes |
| 2004-02-03 00:00:00 | APPROVED BY JOSH LONG PLANNER 659-8031 M |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-06-16 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-06 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-06-16 00:00:00 | DENIED, WAITING FOR AN OPINION FROM THE | | | LAW DEPT. SEND THROUGH THE BUILDING | | | DIVISION FOR REVIEW, RETURN TO ZONING | | | AFTER THE BLDG DIVISION REVIEW |
|
|