| Plan Review Stops For Permit 03060274 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
14 |
Status |
F |
Date |
2005-12-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-12-05 |
Time |
11:45 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-12-05 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2005-12-05 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | STAIR SUBMITTAL | | | | | | 1.)ALL SUBMITTALS ARE TO BE REVIEWED | | | BY DESIGNER OF RECORD. | | | | | | 2.)SEE SHEETS 10 AND 16.THE HANDRAIL | | | EXTENSION AT THE TOP OF THE STAIRS IS TO | | | BE PARALLEL WITH THE FLOOR SURFACE, | | | FBC11-4.9.4(2), FBC1007.5.5. | | | | | | 3.)PLEASE CLARIFY AS TO WHY THE | | | HANDRAIL EXTENSION DETAIL ON SHEET 11 IS | | | NOT THE SAME AS SHEET 10, WHICH IS | | | COMPLIANT.SEE FBC11-4.9.4, FBC FIGURE | | | 19. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
F |
Date |
2005-12-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-12-05 |
Time |
11:30 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-12-05 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2005-12-05 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | FIREPROOFING SUBMITTAL | | | | | | 1.)ALL SUBMITTALS ARE TO BE REVIEWED | | | BY DESIGNER OF RECORD. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
F |
Date |
2005-10-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-10-03 |
Time |
09:25 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-10-03 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2005-10-03 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)THE SEALED DETAIL HAS A PHOTOPCY OF | | | A SIGNATURE.THIS IS NOT ACCEPTABLE AS | | | PER FBPE.IF YOU DISAGREE, PLEASE | | | CONTACT FBPE FOR CLARIFICATION AND | | | PROVIDE ME WITH THE NAME OF AN | | | INDIVIDUAL WHO I CAN SPEAK WITH. | | | OTHERWISE, SUBMIT ONLY SIGNED, SEALED | | | AND DATED ORIGINALS. | | | | | | 2.)THE TITLE BLOCK IS NOT IN | | | COMPLIANCE WITH FAC61G15-23.002. IT IS | | | MISSING THE FOLLOWING:CA NUMBER FOR | | | THE FIRM, PRINTED NAME AND LICENSE | | | NUMBER OF THE PERSON SEALING THE | | | DOCUMENT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
F |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-12 |
Time |
17:10 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-07-12 |
Time |
17:10 |
Sent To |
PC |
|
| Notes |
| 2005-07-12 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE DETAIL PREPARED BY ONM&J WAS A | | | PHOTOCOPY.ALL DOCUMENTS SUBMITTED FOR | | | PUBLIC RECORD PREPARED BY AN ENGINEER | | | ARE TO BE SIGNED SEALED ORIGINALS | | | FAC61G15-23.002. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-07-12 |
Time |
17:02 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-07-12 |
Time |
17:02 |
Sent To |
PC |
|
| Notes |
| 2005-07-12 00:00:00 | FLOOR & ROOF TRUSS ENGINEERING | | | LINTON TRUSS/JULIUS LEE PE | | | | | | GLASS SHOPS PREPARED BY F BENNARDO PE | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2005-06-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-09 |
Time |
09:59 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-06-09 |
Time |
09:59 |
Sent To |
PC |
|
| Notes |
| 2005-06-09 00:00:00 | S1 - S5 (NOTE - NO CHANGES ON S1 - S3) | | | DATED 5/23/05 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2005-05-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-05-19 |
Time |
15:00 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-05-19 |
Time |
15:00 |
Sent To |
PC |
|
| Notes |
| 2005-05-19 00:00:00 | ****CORRECTIONS**** | | | TRUSS SUBMITTAL | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SEE ATTCHED FROM THE SIMPSON | | | CATALOG.THE LOADS ON THE CONNECTOR | | | SCHEDULE PROVIDED ARE HIGHER THAN THE | | | CATALOG.ALSO, WHAT IS THE LAST COLUMN, | | | WIND (133)? | | | | | | 2.)APPARENTLY THE EOR HAS REDLINED THE | | | FLOOR LOADING.THE LOADING REQUIRED BY | | | EOR IS HIGHER THAN THE LOADS INDICATED | | | IN THE ENGINEERING. | | | | | | 3.)A TITLE BLOCK IS REQUIRED ON THE | | | TRUSS ENGINEERING, FAC61G15-23.002. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2005-03-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-03-25 |
Time |
16:47 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-03-25 |
Time |
16:47 |
Sent To |
PC |
|
| Notes |
| 2005-03-25 00:00:00 | TRUSS ENGINEERING | | | PARTIAL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2004-04-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-04-06 |
Time |
15:35 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2004-04-06 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-01-28 |
Time |
15:25 |
Rev Time |
4.00 |
| Received By |
shill |
Date |
2004-01-28 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2004-01-28 00:00:00 | *****CORRECTIONS****** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SEE PREVIOUS LISTS IN REGARDS TO | | | PRODUCT APPROVALS.ANY TEST REPORTS | | | REQUIRED BUT NOT SUBMITTED WILL REQUIRE | | | SEPARATE PERMITS. | | | | | | 2.)THE NOTICE OF COMMENCEMENT IS | | | EXPIRED (90 DAYS WITHOUT COMMENCING | | | WORK), FS713.13.THIS MAY BE PROVIDED | | | AT TIME OF PERMIT ISSUANCE. | | | | | | 3.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE | | | STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 FOR MORE | | | INFORMATION. | | | | | | 4.)SEE PREVIOUS LIST, ITEM #5.THE | | | PLANS STILL SHOW CASEMENT WINDOWS. | | | SEE THE WINDOW SPRINKLER DOCUMENTATION; | | | FIXED GLASS ONLY ALLOWED. | | | | | | 5.)SEE ATTACHED NOTICE IN REGARDS TO | | | FS553.80(2)(B).A 4X FEE HAS BEEN | | | CHARGED (REQUEST FOR SPRINKLER PLANS | | | NOT ADDRESSED THREE TIMES).SEE ITEM | | | #5 ABOVE.THIS IS THE SECOND TIME THAT | | | THIS CORRECTION HAS BEEN MADE.A | | | SECOND 4X FEE WILL BE CHARGED IF THIS | | | IS NOT ADDRESSED ON THE NEXT REVIEW. | | | SEE ATTACHED BZ235301. | | | | | | 6.)BEFORE RESUBMITTING, HAVE ANY | | | REVISED SHEETS STAMPED BY THE HISTORIC | | | PRESERVATION DIVISION. | | | | | | 7.)THE HYDRAULIC CALCULATIONS ARE | | | REQUIRED TO HAVE THE ENGINEER'S | | | INFORMATION INCLUDED ON THE COVER | | | SHEET. | | | | | | 8.)THE MODEL WS SPRINKLER HEAD IS | | | REQUIRED TO BE A MINIMUM OF 6' FROM | | | STANDARD SPRINKLER HEADS, SEE 2ND FLOOR | | | PLAN. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2003-11-07 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-11-07 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-11-07 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2003-11-07 00:00:00 | THIS IS THE FOURTH REQUEST FOR THE | | | DESIGN INFORMATION OF THE FIRE | | | PROTECTION SYSTEM TO BE PROVIDED THE | | | PLANS. | | | | | | THE CARRIBBEAN FIRE & ASSOCIATES | | | HYDRAULIC CALCULATIONS DO NOT COMPRISE | | | A DESIGN.SEE NFPA 13-99 CHAPTER 8, | | | SECTION 8-1.1.1 AND THE FLORIDA | | | ADMINISTRATIVE CODE CHAPTER 61G15-32 | | | RESPONSIBILITY RULES OF PROFESSIONAL | | | ENGINEERS CONCERNING THE | | | DESIGN OF FIRE PROTECTION SYSTEMS. | | | | | | THE PLANS DO NOT REFLECT ACCOMODATION OF | | | THE TYCO/CENTRAL SPRINKLER HEADS AS | | | DESCRIBED IN THE TWO CUT SHEETS | | | PROVIDED. | | | | | | AN ACCEPTABLE INSTALLATION METHOD IS | | | THAT CONTAINED IN THE NER REPORT #516 | | | AND THE MANUFACTURER'S PUBLISHED | | | INSTRUCTIONS. | | | | | | SOME OF THE EXISTING CONFLICTS ARE: | | | 1) OPERABLE WINDOWS, THE DESIGN REQUIRES | | | FIXED GLASS. | | | 2) HORIZONTAL MULLIONS, THE DESIGN DOES | | | NOT ALLOW THEM. | | | 3) DELUGE HEADS ON THE EXTERIOR AND | | | INCLUDED IN THE MOST DEMANDING AREA OF | | | THE HYDRAULIC CALCUALATIONS. | | | | | | SEE NOTES #2 & #6 ON THE 8/26/03 LIST. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2003-08-26 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-08-26 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-08-26 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2003-08-26 00:00:00 | 1THE REQUESTED SIGNED SEALED AND | | | DATED SURVEY HAS NOT BEEN PROVIDED. | | | | | | 2THIS IS THE THIRD REQUEST FOR THE | | | FIRE SPRINKLER PROTECTION DESIGN.THE | | | ARCHITECT'S LETTER DATED 8/18/03 | | | DECLARING COMMENTS 1, 2 & 3 ARE THE | | | CONTRACTOR'S RESPONSIBILITY IS NOT | | | WITHSTANDING.FLORIDA STATUTE 553.80 | | | (2) (B) REQUIRES A FEE TO BE PAID OF | | | FOUR TIMES THE AMOUNT OF THE PLAN | | | REVIEW PORTION EACH TIME AFTER THE | | | THIRD REVIEW. THIS IS IN ADDITION TO | | | ANY OTHER FEES THAT MAY BE DUE.SEE | | | THE ATTACHED NOTICE AND FBC 104.3.1.1 | | | #5. | | | | | | 3THIS IS THE THIRD REQUEST FOR THE | | | FIRE DESIGN NUMBER OF THE "NEW" | | | EXTERIOR MASONRY WALLS AND INFILL AREAS. | | | THE ARCHITECTS CITATION FOR THE | | | EXISTING WALLS IS NOTED.SEE FBC | | | 701.5.1. | | | | | | 4AS PREVIOUSLY NOTED, FBC TABLE 600 | | | REQUIRES "THREE" HOUR FIRE RATING FOR | | | EXTERIOR WALLS LOCATED 0' - 3' FROM A | | | COMMON PROPERTY LINE FOR TYPE V | | | CONSTRUCTION, NOT THE DECLARED TWO HOUR. | | | PLEASE REVISE AS NECESSARY AND SEE ITEM | | | #3 ABOVE. | | | | | | 5WITH THE ABOVE FIRE SPRINKLER DESIGN | | | INFORMATION INCLUDE THE LISTING, TEST | | | DATA FOR THE HEADS THAT WILL PROVIDE A | | | TWO HOUR FIRE RATEDOPENING PROTECTION. | | | | | | 6COMMENTS IN THE TWO PREVIOUS LISTS | | | REMAIN WITH REGARDS TO IMPACT FEES, | | | NOA'S FOR THE DOORS, WINDOWS AND ROOF | | | COVERINGS, AND THE PROPRIETARY MASONRY | | | IN THE U905DESIGN.THESE ARE NOT | | | CAUSE FOR REJECTION BUT ADVISORY TO THE | | | CONTRACTOR AND OWNER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-07-29 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-07-29 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-07-29 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2003-07-29 00:00:00 | 1THE PROPERTY SURVEY'S PROVIDED ARE | | | NOT SIGNED AND SEALED.PLEASE PROVIDE | | | COPIES WITH ORIGINAL SIGNATURE AND | | | EMBOSSED SEAL. | | | | | | 2AS NOTED IN THE PREVIOUS CODE | | | COMMENTS THE FIRE SPRINKLER SYSTEM | | | DESIGN IS REQUIRED TO BE ON THE PERMIT | | | PLANS.SEE FBC 104.3.1.1, #5. | | | | | | 3THE ARCHITECT'S RESPONSE MEMO DATED | | | 7/18/03 REFERENCING A MEETING WITH THE | | | BUILDING OFFICIAL IMPLIES THAT AN | | | APPROVAL WAS GRANTED AT THAT TIME.IT | | | WAS AND IS THE BUILDING OFFICIAL'S | | | INTENTION THAT ANY CODE VARIANCES MAY | | | COME ONLY THROUGH THE CITY'S | | | CONSTRUCTION BOARD OF ADJUSTMENTS AND | | | APPEALS FOR WHICH THERE IS AN | | | OUTSTANDING APPLICATION DATED 3/03. | | | | | | THEREFORE THE TABLE 600 ISSUES REMAIN | | | TO BE RESOLVED AS WELL AS THE | | | EXTERIOR WALL RATINGS. | | | | | | 4THE ORIGINAL PERMIT APPLICATION IS | | | NOT INCLUDED WITH THE RE-SUBMITTED | | | PLANS. | | | | | | 5AS PREVIOULSY NOTED, THIS PROJECT IS | | | SUBJECT IMPACT FEES COLLECTED BY THE | | | COUNTY PRIOR TO PERMIT ISSUE. | | | | | | 6SHEET A9.2, DESIGN # U905 REQUIRES | | | THE BLOCK MANUFACTURER TO BE A UL | | | CERTIFICATE HOLDER.PLEASE VERIFY THIS | | | WITH YOUR VENDOR AND PROVIDE | | | DOCUMENTATION TO THIS OFFICE. | | | | | | 7IF TEST AND/OR NOTICE OF ACCEPTANCE | | | REPORTS ARE NOT INCLUDED WITH THIS | | | PERMIT APPLICATION FOR THE WINDOWS, | | | DOORS AND ROOF COVERING, SEPARATE | | | PERMITS, PLANS AND FEES WILL BE | | | REQUIRED FOR THAT PORTION OF THE WORK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-07-08 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-07-08 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-07-02 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2003-07-08 00:00:00 | 1 PLEASE PROVIDE A RECENT PROPERTY | | | SURVEY TO DETERMINE LOCATION OF | | | ADDITION AND ALTERATIONS. | | | | | | 2THE ADDITION IS SUBJECT TO IMPACT | | | FEES COLLECTED BY THE COUNTY.THE | | | PERMIT PLANS MUST BE STAMPED BY THAT | | | OFFICE AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | CALL 561-233-5025 FOR MORE INFORMATION. | | | | | | 3THE PERMIT PLANS MUST HAVE THE FIRE | | | SPRINKLER DESIGN INFORMATION ON THEM. | | | SEE FBC 104.3.1.1. | | | | | | 4THE EAST AND WEST SIDES OF THIS | | | BUILDING ARE ZERO LOT LINE SETBACK AND | | | FBC TABLE 600 DOES NOT ALLOW ANY | | | OPENINGS.PLEASE REVISE AS NECESSARY. | | | | | | 5THE SOUTH SIDE, (ALLEY), PROPERTY | | | LINE IS MEASURED FROM THE CENTER OF THE | | | ALLEY.PLEASE REVISE THAT ELEVATION TO | | | BE IN ACCORDANCE WITH FBC TABLE 600 AND | | | FBC 705.1. | | | | | | 6THE FRONT AND PROPOSED REAR DOORS | | | APPEAR TO SWING OVER THE PUBLIC RIGHT | | | OF WAY.SEE FBC 3203. | | | | | | 7SHOW THE METHOD OF COMPLIANCE FOR | | | FBC 1803.2 FOR THE FOUNDATION WORK IN | | | THE PROXIMITY OF THE ADJACENT BUILDINGS. | | | | | | 8FBC TABLE 600 REQUIRES A THREE HOUR | | | FIRE RATING FOR EXTERIOR BEARING WALLS | | | LOCATED 0'-3' FROM A PROPERTY LINE IN | | | TYPE V CONSTRUCTION.PLEASE SHOW THE | | | FIRE DESIGN NUMBER FOR THESE WALLS TO | | | BE CONSTRUCTED AND MODIFIED. SEE FBC | | | 701.5.1. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-10-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-27 |
Time |
16:35 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-10-27 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2003-10-27 00:00:00 | PASSED , PENDING FIRE REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2003-09-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-09-08 |
Time |
14:18 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-09-08 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2003-09-08 00:00:00 | ********** NOTE *************** | | | | | | PLEASE SEE FIRE REVIEW COMMENTS. | | | SD'S MUST BE 3'FROM KITCHEN DOOR/OPENING | | | WHICH THEY APPEAR TO BE. NFPA-72 2-5.2.1 | | | .6. PLEASE GET WITH MIKE CARSILLO ON | | | SD PLACEMENT AND PERHAPS HEAT DETECTORS | | | PERMITTTED IN SD'S PLACE? | | | | | | ELECTRICAL PLANS SEEM TO BE OK. | | | PLEASE SEE RISER, SHOWS ALL SUB PANELS | | | AS 125A,PANELS ARE SHOWN AS 100A AND 42 | | | CIRCUIT. PLEASE CORRELATE RISER AND | | | PANELS. PLEASE ALSO NOTE, 100A AND 125A | | | PANELS DO NOT COME W/ 42 CIRCUITS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION, | | | PLEASE SEE FIRE COMMENTS FOR ELEC SHEETS | | | PLEASE SEE THAT ELECTRICAL PLANS FOR THE | | | MOST PART ARE OK. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | PLEASE CALL FOR ANY QUESTIONS ABOUT SD'S | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-07-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-07-29 |
Time |
18:00 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-07-29 |
Time |
18:00 |
Sent To |
|
|
| Notes |
| 2003-07-29 00:00:00 | ************** UNSAT ***************** | | | | | | PLEASE ADDRESS COMMENTS BELOW. PLANS | | | ARE COMING BACK FOR OTHER REVIEWERS. | | | | | | 1)NOTE: PLEASE SEE 3W/ SQ FT STILL SHOWN | | | AS ROUNDING DOWN ON UNITS B&C, | | | PLEASE ALSO SEE LOAD FOR DRYER SHOWN | | | AT 3KW. PLEASE SEE MIN PER 220-18 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-06-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-06-23 |
Time |
08:00 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-06-23 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2003-06-23 00:00:00 | ************ UNSAT *************** | | | | | | PLEASE SEE COMMENTS FROM FIRE PLAN | | | REVIEW FOR POSSIBLE COMENTS THAT WILL | | | HAVE AN AFFECT ON ELECTRICAL PLANS. | | | | | | 1)NOTE: MISSING SMOKE DETECTORS AS REQ`D | | | INSIDE AND OUTSIDE SLEEPING RMS. | | | NFPA-72 8-1 | | | | | | 2)NOTE: PLEASE SEE SOME RECEPTS MISSING | | | PER 210-52 | | | | | | 3)NOTE: PLEASE SHOW ALL RECEPT SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | | ED. 210-8-A6 | | | | | | 4)NOTE: PLEASE SEE 210-11C1 FOR A MIN | | | OF TWO SMALL APPL CIRCUITS REQ`D. | | | EACH AT 1500VA | | | | | | 5)NOTE: PLEASE LIST THE REQ`D ARC FAULT | | | PROTECTED CIRCUITS. 210-12 | | | | | | 6)NOTE:PLEASE SUBMIT AIC RATINGS FOR | | | MAIN AND SUB MAINS. 110-9/215-5 | | | | | | 7)NOTE: PLEASE SEE THAT LIGHTING LOAD | | | FIGURED FOR UNITS ARE FIGURED TO 3WATTS | | | PER SQFT, HOWEVER SOME SHOWN ROUNDING | | | DOWN. ROUNDING UP IS PERMITTED, HOWEVER | | | ROUNDING DOWN IS NOT. | | | | | | 8)NOTE: PLEASE SEE 600-5 FOR MIN SIGN | | | CIRCUIT REQ`D . | | | | | | 9)NOTE: PLEASE SHOW REQ'D SHOW WINDOW | | | RECEPTS PER 210-62 | | | | | | PLEASE SEE ANY COMMENTS FROM OTHER | | | REVIEWERS THAT HAVE AN AFFECT ON ELECTR- | | | -ICAL PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
P |
Date |
2004-01-21 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-01-21 |
Time |
11:12 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2004-01-21 |
Time |
11:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2003-10-29 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-10-29 |
Time |
10:37 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-10-29 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2003-10-29 00:00:00 | FAILED: | | | 1. PLEASE REFER TO THE REVIEW COMMENTS | | | DATED 8-27-03, SEE ATTACHED. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2003-08-27 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-08-27 |
Time |
09:56 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-08-27 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2003-08-27 00:00:00 | FAILED: | | | 1. SHEET P-1 AND P-2 REFERS TO CIVIL | | | DRAWING FOR EXACT LOCATION FOR | | | CONNECTIONS AND CONTINUATION OF SANITARY | | | , STORM WATER AND DOMESTIC WATER, NO | | | CIVIL PLANS HAS BEEN PROVIDED. | | | 2. PLEASE NOTE THAT ANY NEW CONNECTIONS | | | TO CITY SERVICES REQUIRES APPROVAL FROM | | | PUBLIC UTILITIES & ENGINEERING,659-8040 | | | 3. BACKFLOW ASSEMBLY MUST BE LOCATED ON | | | PROPERTY AND LOACTION MUST BE APPROVED | | | BY PUBLIC UTILITIES & ENGINEERING, | | | 659-8040. | | | 4. SHEET P-1, FIRST FLOOR PLAN-SANITARY, | | | NOTE THAT STORM DRAIN LEADER SHUOLD BE | | | CONNECTED TO STORM DRAINAGE AND | | | SANITARY DRAIN TO SANITARY SYSTEMS, | | | PLEASE VERIFY. | | | 5. KEYNOTES, NUMBRING THROUGHOUT THE | | | BUILDING FROM FLOOR TO FLOOR NOT | | | CONSISTENCE, SHEET P-1 AND P-2, PLEASE | | | VERIFY. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2003-07-08 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-07-08 |
Time |
10:27 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2003-07-08 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2003-07-08 00:00:00 | FAILED: | | | 1. PLEASE STATE IF GARBAGE IS TO BE | | | PICKED UP BY THE CITY OR IF IT IS | | | PRIVATE PICKUP, IF TO BE PICKED UP BY | | | THE CITY THEN THE CITY REQUIREMENTS MUST | | | BE MET. SEE ATTACHED. | | | 2. DOORS FOR THE DUMPSTER AS PROPOSED | | | COULD NOT SWING OPEN INTO THE PUBLIC | | | R.O.W. | | | 3. DUMPSTER AS PROPOSED MUST BE APPROVED | | | BY THE SANITATION DEPARTMENT 659-8048 | | | EXT. 2273 , JOHNNY THOMAS. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
P |
Date |
2004-04-01 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-04-01 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-04-01 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2004-04-01 00:00:00 | 1) FIRE ALARM CIRCUITS TO BE CLASS A | | | OR FULLY ADDRESSABLE. | | | | | | 2) ANY ELECTRONIC LOCKING DEVICES SHALL | | | MEET THE REQUIREMENTS OF NFPA 101, | | | CHAPTER SEVEN. | | | | | | 3) FIRE SPRINKLER SYSTEM INSTALLATION | | | SHALL MEET THE REQUIRMENTS OF NFPA 13, | | | 1999 EDITION. A FIRE DEPARTMENT | | | CONNECTION IS REQUIRED. | | | | | | 4) ARCHITECTURAL PLANS INDICATES THAT | | | EXTERIOR COVERED AREA TO BE FULLY | | | SPRINKLERED. THE SPRINKLER PLANS | | | DO NOT SUGGEST IT. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2004-01-08 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-08 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-08 |
Time |
17:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2003-10-31 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-10-30 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-10-30 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2003-10-30 00:00:00 | 1) FIRE ALARM NOTES # 11 INDICATES | | | A SUPERVISORY SIGNAL UPON ACTIVATION | | | OF DUCT SMOKE DETECTORS. ACTIVATION | | | OF ANY DUCT SMOKE DETECTOR SHALL | | | CAUSE THE FIRE ALARM SYSTEM TO ACTIVATE. | | | | | | 2) BUILDING ADDRESS REQUIRED ON PROPER | | | ELEVATION. | | | | | | 3) FIRE ALARM CIRCUITS SHALL BE CLASS A | | | OR FULLY ADDRESSABLE. | | | | | | 4) SECURITY LOCKS CONNECTED TO THE | | | FIRE ALARM SYSTEM SHALL COMPLY WITH | | | EITHER ACCESS CONTROL OR DELAYED | | | EGRESS REQUIREMENTS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2003-09-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-09-04 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-09-04 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2003-09-04 00:00:00 | 1) TACTILE SIGNAGE REQUIRED AT STAIRS. | | | | | | 2) ALL SHAFTWAYS THAT PERSONS CAN FALL | | | INTO MUST BE MARKED "SHAFTWAY" WITH | | | 6" HIGH LETTERS. | | | | | | 3) SIGNS ARE REQUIRED AT ELEVATORS | | | DO NOT USE ELEVATORS IN THE EVENT OF | | | A FIRE. | | | | | | 4) SINCE FIRE ALARM PERMITS ARE EXPECTED | | | AFTER AUGUST 1, 2003, THE FIRE ALARM | | | SYSTEM IS EXPECTED TO MEET UL LISTED | | | FOR CENTRAL STATION SERVICE SINCE THE | | | PERMIT APPLICATION WILL FALL AFTER | | | THE AUGUST 1, 2003, IMPLEMENTATION DATE. | | | | | | 5) IT APPEARS THAT SMOKE DETECTORS ARE | | | INSTALLED IN THE KITCHENS. SMOKE | | | DETECTORS ARE NOT INSTALLED IN KITCHENS | | | AREAS. IT DOES APPEAR THAT THE DESIGNER | | | IS TRYING TO MEET THE INTENT OF | | | SMOKE DETECTORS INSIDE AND OUTSIDE | | | THE SLEEPING ROOMS BUT WHAT PREVENTS | | | FALSE OR NUISANCE ALARMS. ALSO ARE | | | THESE SMOKE DETECTORS SINGLE STATION | | | AS REQUIRED OR ARE THEY PLANNED TO | | | BE CONNECTED TO THE FIRE ALARM SYSTEM. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-08-11 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-08-11 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-08-11 |
Time |
14:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-07-01 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-07-01 |
Time |
07:36 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-07-01 |
Time |
07:36 |
Sent To |
|
|
| Notes |
| 2003-07-01 00:00:00 | 1) ALL DEMOLITION, RENOVATION, AND | | | CONSTRUCTION SHALL COMPLY WITH NFPA 241. | | | | | | 2) SUITABLE EXITS ARE TO BE PROVIDED | | | DURING DEMOLITION, RENOVATION AND | | | CONSTRUCTION ACTIVITIES. | | | | | | 3) PLEASE INDICATE LOCATIONS OF ALL | | | SMOKE DETECTORS CONTAINED WITHIN THE | | | APARTMENTS. ELECTRIC POWERED SMOKE | | | DETECTORS ARE REQUIRED INSIDE AND | | | OUTSIDE OF ALL SLEEPING ROOMS. | | | | | | 4) PLEASE PROVIDE MORE DETAILS ON NOTE | | | 19 ON PAGE A3.1. "PROVIDE TWO HOUR | | | FIRE SPRINKLER HEADS (1 EXTERIOR, 1 | | | INTERIOR) ABOVE EACH WINDOW. | | | | | | 5) PLEASE PROVIDE A NOTE ABOUT EGRESS | | | WINDOWS. PLEASE EXPLAIN EXEPTIONS THAT | | | YOU ARE USING. | | | | | | 6) NO FIRE SPRINKLER PLANS PROVIDED. | | | | | | 7) A KNOX-BOX WILL BE REQUIRED. | | | | | | 8) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FIRE ALARM SYSTEM. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2005-11-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-17 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-17 |
Time |
13:28 |
Sent To |
B |
|
| Notes |
| 2005-11-17 00:00:00 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2005-09-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-30 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-30 |
Time |
15:49 |
Sent To |
B |
|
| Notes |
| 2005-09-30 00:00:00 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-26 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-26 |
Time |
11:07 |
Sent To |
M |
|
| Notes |
| 2005-07-26 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-12 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-12 |
Time |
15:58 |
Sent To |
B |
|
| Notes |
| 2005-07-12 00:00:00 | TO "SHILL" DESK/2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-07-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-06 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-06 |
Time |
14:44 |
Sent To |
P |
|
| Notes |
| 2005-07-06 00:00:00 | TO "P" BOX/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-08 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-08 |
Time |
08:49 |
Sent To |
B |
|
| Notes |
| 2005-06-08 00:00:00 | TO SH DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-05-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-17 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-17 |
Time |
16:43 |
Sent To |
B |
|
| Notes |
| 2005-05-17 00:00:00 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-03-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-25 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-25 |
Time |
11:33 |
Sent To |
B |
|
| Notes |
| 2005-03-25 00:00:00 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-03-31 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-03-31 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-03-31 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2004-03-31 00:00:00 | TO COMMERCIAL BOARD #59 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-12-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-30 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-30 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2003-12-30 00:00:00 | TO COMM BD#63 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-10-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-24 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-24 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2003-10-24 00:00:00 | TO COMM BD#62 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-08-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-25 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-25 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2003-08-25 00:00:00 | ON COMM BD #38 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-07-23 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-23 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-23 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2003-07-23 00:00:00 | IN COMM BOX #48 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-06-05 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-05 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-05 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2003-06-05 00:00:00 | COMM BOARD #33 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-08-01 |
Time |
08:10 |
Rev Time |
0.50 |
| Received By |
prafter |
Date |
2005-08-01 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2005-08-01 00:00:00 | MECH. PLAN REVIEW: | | | | | | A/C REV. #6 R.T.U. CURB DWTAIL. | | | | | | PR 8/1/05. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2003-11-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-11-18 |
Time |
08:50 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-11-18 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2003-11-18 00:00:00 | PROVISO: | | | PLEASE NOTE THE LOCATION OF THE FRESH | | | AIR INTAKE IN RELATION TO THE DUMPSTER. | | | AS PER 2001 FBC(M) INTAKE OPENINGS SHALL | | | BE LOCATED A MINIMUM OF 10 FT FROM ANY | | | NOXIOUS CONTAMINANT (ALLEYS, PARKING LOT | | | & LOADING DOCKS). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-09-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-09-23 |
Time |
13:19 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-09-23 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2003-09-23 00:00:00 | PROVISO: | | | PLEASE PROVIDE OUTSIDE CALCULATIONS FOR | | | THE FIRST FLOOR "SALES SPACE 10" WITH | | | RESUBMITTAL. | | | | | | PLEASE PROVIDE INFORMATION ON THE FIRST | | | FLOOR IN RESPECT TO VENTILATION. | | | MINIMUM VENTILATION REQUIRED EVEN THOUGH | | | BUILD-OUT OF THE FIRST FLOOR WILL BE | | | ADDRESSED UNDER A SEPARATE PERMIT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2003-08-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-08-12 |
Time |
07:57 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-08-12 |
Time |
07:44 |
Sent To |
|
|
| Notes |
| 2003-08-12 00:00:00 | DENIED: | | | | | | ONE SET OF PLANS IS MISSING PLAN SHEETS | | | M-3 AND M-4.PLEASE PROVIDE TWO | | | COMPLETE SET OF PLANS FOR REVIEW. | | | PLANS ARE CODE COMPLIANT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-06-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-06-26 |
Time |
19:28 |
Rev Time |
1.50 |
| Received By |
hmoser |
Date |
2003-06-26 |
Time |
19:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-07-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-07-19 |
Time |
13:53 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2005-07-19 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2005-07-19 00:00:00 | REVISED PAGE P-1 RWL'S TO GO OUT BACK | | | INSTEAD OF THE FRONT. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-08-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-07 |
Time |
16:39 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-08-07 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2003-08-07 00:00:00 | PASSED/PROVISO | | | | | | EMERGENCY STORM RISER PIPE SIZES TO RE- | | | FLECT PIPE SIZES SHOWN ON SHEET P-1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-06-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-25 |
Time |
09:31 |
Rev Time |
2.75 |
| Received By |
kstevens |
Date |
2003-06-24 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2003-06-25 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | FBC-2001 CHAP. 1, AMENDMENTS | | | ADMIN CODE | | | FHA-98 DESIGN MANUAL | | | FBC-2001 MECHANICAL | | | | | | 1) SHT A2.1 FIRST FLOOR PLAN DETAIL #1. | | | PER TABLE 403.1 A UNISEX TOILET ROOM | | | COMPLYING WITH 11-4.22 AND A DRINKING | | | FOUNTAIN ARE REQUIRED. | | | 2) SHT A2.1 SECOND FLOOR PLAN DETAIL #2, | | | PER TABLE 403.1 AUTOMATIC CLOTHES WASHER | | | CONNECTION REQUIRED. (ALSO SEE FOOTNOTE | | | "F"). | | | 3) SHT A5.1 SHOW CLEAR FLOOR SPACE ON | | | TYPICAL TOILET ROOM PLAN DETAIL #1, AND | | | TYPICAL KITCHEN PLAN DETAIL #3 PER FHA | | | DESIGN MANUAL PAGE 7.43 | | | 4) SHT A5.1 DETAIL #1 INDICATE MEASURE- | | | MENT OFF TUB AND LAV TO CENTER LINE OF | | | W/C. MINIMUM 18" REQUIRED OFF 1 FIXTURE | | | OR THE OTHER AND MINIMUM OPENING REQUIR- | | | ED IS 33". PLEASE SHOW OPENING SIZE. | | | SEE FIGURES 1, 2, OR 3 PAGE 7.43 DESIGN | | | MANUAL | | | 5) SHT P-1 DETAIL #03, SUBMIT CALCULAT- | | | IONS FOR PRIMARY AND SECONDARY ROOF | | | DRAINS PER SECTIONS 1106 & 1107 AND ALL | | | SUBSECTIONS. CHECK OF NORTH SECTION OF | | | ROOF SCALES OUT 47.83 FT TIMES 24.83 FT | | | EQUALS 1,188 SQ.FT. NOT COUNTING 1/2 | | | AREA OF VERTICAL WALLS, INCLUDING PARA- | | | PETS. (SECTION 1106.4). PLAN SHOWS 1,109 | | | SQ.FT. PLEASE CLAIRFY. SHOW CALCULATIONS | | | FOR EACH AREA, NORTH, CENTER , & SOUTH. | | | ALSO SHOW AREAS OF ROOF THAT DRAIN ONTO | | | THE ROOF SECTIONS FROM ABOVE, I.E. | | | STAIRWAYS & MECHANICAL ROOMS ECT. SECT- | | | ION 1106.2 | | | 6) SHT P-1 DETAIL #2, SECOND FLOOR SANT. | | | STATES "EWH DRAIN LINE PROVIDE TRAP" | | | PLEASE CLAIRFY, IS THIS A CONDENSATE | | | LINE OR THE PAN DRAIN LINE FOR THE | | | ELECTRIC WATER HEATER? | | | 7) SHT P-4 WATER ISOMETRIC, AIR CHAMBERS | | | ARE NOT APPROVED. (TUB/SHOWER VALVES). | | | DELETE FROM RISERS. WATER HAMMER ARREST- | | | ORS AT WATER HEATERS SHALL BE LOCATED | | | NEAR THE FIXTURE IN AN "EFFECTIVE RANGE" | | | NOT IN THE CEILING. PDI-WH201 AND MANUF. | | | INSTALLATION INSTRUCTIONS. | | | 8) SUBMIT RISER DIAGRAM FOR EMERGENCY | | | PAN DRAINS FOR WATER HEATERS. SHOW PIPE | | | SIZE AND INDICATE TYPE OF MATERIAL. | | | SECTION 504.8, 504.8.1, & 504.8.2. | | | 9) SHT P-6 PLUMBING SPECIFICATIONS #2-M | | | ADOPTED CODE IS FBC-2001 PLUMBING, NOT | | | STANDARD CODE 1999 EDITION. CHANGE REF- | | | ERENCE. - #3-L AIR CHAMBERS ARE NOT | | | APPROVED. DELETE FROM REFERENCE. SECTION | | | 604.9- #4-F AIR CHAMBERS ARE NOT | | | APPROVED. DELETE FROM REFERENCE. | | | 10) INDICATE ON PLANS IF SPECIFICATION | | | "A" OR "B" WILL BE FOLLOWED FOR THE | | | BATHROOMS IN EACH UNIT. PAGES 7.34 & | | | 7.35FHA DESIGN MANUAL. | | | 11) ARCHITECTURAL SHEETS - 61G1-16.004 | | | FIRM LICENSES NUMBER IS REQUIRED ON THE | | | TITLE BLOCK | | | 12) SHT P-3 CONDENSATE DRAIN ISOMETRIC. | | | UNABLE TO FIND THE REST OF THE CONDENS- | | | ATE RISER DIAGRAM REFERED TO ON THE | | | MECHANICAL PLANS. SUBMIT A COMPLETE | | | CONDENSATE RISER DIAGRAM SHOWING ALL | | | PIPE SIZES AND MATERIAL USED. | | | 13) SHT M-1 CONDENSATE FROM ROOF UNITS | | | SHOW SOME DRAINING TO THE ROOF DRAINS, | | | AND OTHERS DRAINING TO THE SECONDARY | | | ROOF DRAINS. ALL SHALL DRAIN TO THE | | | ROOF DRAINS. SECTION M307.2.1(3). | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-06-27 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-06-27 |
Time |
15:29 |
Rev Time |
1.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-06-27 00:00:00 | 6/27/03 PASS PER ANTHIA MM |
|
|