| Plan Review Stops For Permit 03060080 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-03-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-03 |
Time |
14:46 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-03-03 |
Time |
14:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-01 |
Time |
13:52 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-01-22 |
Time |
13:18 |
Sent To |
Z |
|
| Notes |
| 2004-01-22 00:00:00 | ****CORRECTIONS***** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SEPARATE PERMITS REQUIRED. | | | | | | 2.)SEE PREVIOUS LIST, ITEM #3, SHEET | | | 2 REFERS TO "BUILDING UNLOAD CERTIFICA- | | | TION", REVISE. | | | | | | 3.)SEE PREVIOUS LIST, #7.PROVIDE | | | TWO COPIES OF COMPLETE, CURRENT NOAS | | | FOR THE DOOR.IF NOT SUBMITTED, A | | | SEPARATE PERMIT WILL BE REQUIRED. | | | | | | 4.)SEE PREVIOUS LIST, ITEM #16.IF | | | AN INSTALLATION SCHEDULE IS NOT | | | SUBMITTED, A SEPARATE PERMIT FOR | | | SHUTTERS WILL BE REQUIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-11-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-01-22 |
Time |
10:50 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-11-19 |
Time |
15:50 |
Sent To |
E |
|
| Notes |
| 2003-11-19 00:00:00 | ******CORRECTIONS***** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.)SEPARATE PERMITS REQUIRED. | | | | | | 2.)SEE PREVIOUS LIST, ITEM #4.YOU | | | CANNOT SPECIFY R4 OR R4.2 WHEN THE | | | ENERGY CALCS REQUIRE A MINIMUM OF 4.2. | | | | | | 3.)SEE PREVIOUS LIST, ITEM #9, NOT | | | ADDRESSED.SHEET 2 REFERS TO "BUILDING | | | UNLOAD CERTIFICATION", REVISE. | | | | | | 4.)SEE PREVIOUS LIST, ITEM #12.THE | | | CONNECTOR SCHEDULE, SHEET 2, SPECIFIES | | | TWO STRAPS BUT UPLIFT SHOWS THE SAME | | | AS ONE.ON THE FRAMING PLAN, CONNECTOR | | | TWO IS SPECIFIED WITH AN UPLIFT WHICH | | | EXCEEDS THE TABLE.REVISE THE UPLIFT. | | | | | | 5.)SEE PREVIOUS LIST, ITEM #13. | | | PROVIDE A WINDOW AND DOOR BUCK | | | ATTACHMENT DETAIL. | | | | | | 6.)SEE PREVIOUS LIST, ITEM #16. | | | PROVIDE TWO COPIES OF THE WINDOW | | | MULLION PRODUCT APPROVAL.THE FLOOR | | | PLAN SHOWS THE WINDOW OPENING AS A | | | SINGLE, SCHEDULE SHOWS AS A "PAIR". | | | | | | 7.)THE DOOR PRODUCT APPROVALS ARE | | | MISSING THE TECHNICAL SHEETS. | | | | | | 8.)ADDITIONAL FEES DUE, $364.43 | | | (VALUE ADJUSTMENT AND RADON), SEE | | | ATTACHED BZ233274. | | | | | | 9.)SEE PREVIOUS LIST.ALL CHANGES | | | TO THE PLAN ARE TO BE CLEARLY MARKED | | | WITH CLOUDS OR TRIANGLES. | | | | | | 10.) THERE IS AN "EXTENDED WALL" ON THE | | | ELEVATION.PROVIDE A DETAIL AND SHOW | | | THE WALL ON THE FOUNDATION PLAN. | | | | | | 11.) CHANGES MADE TO A SEALED PLAN ARE | | | TO BE INITIALED BY THE ENGINEER. | | | | | | 12.) SUBMIT A SECOND COPY OF THE SOILS | | | REPORT. | | | | | | 13.) THE APPROVED ZONING SURVEY IS | | | MISSING FROM THE PACKAGE.SUBMIT, IF | | | AVAILABLE. | | | | | | 14.)IDENTIFY THE JOB ON THE TITLE | | | BLOCK BY EITHER ADDRESS OR LOT NUMBER. | | | | | | 15.)SEE ATTACHED NOTICE IN REGARDS | | | TO FS553.80(2)(B). | | | | | | 16.)PROVIDE A KEY PLAN AND A HURRICANE | | | SHUTTER INSTALLATION SCHEDULE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-07-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-11-18 |
Time |
18:02 |
Rev Time |
3.00 |
| Received By |
sthyng |
Date |
2003-07-09 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2003-07-09 00:00:00 | *******CORRECTIONS******* | | | | | | 1.)SEPARATE PERMITS REQUIRED. | | | | | | 2.)BEFORE A PERMIT CAN BE ISSUED, A | | | NOTICE OF COMMENCEMENT MUST BE FILED | | | WITH THE CLERK OF COURTS. | | | | | | 3.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE | | | STAMPED AND THE ORIGINAL RECEIPT | | | ATTACHED TO THE APPLICATION.233-5025 | | | | | | 4.)THE WALL SECTION SHOWS R4 | | | INSULATION, THE ENERGY CALC SPECIFIES | | | A MINIMUM OF 4.2. | | | | | | 5.)SPECIFY THE SPACING OF THE SOFFIT | | | VENTS TO COMPLY WITH FBC2309.7. | | | | | | 6.)SIGN THE OWNER/AGENT LINE OF THE | | | ENERGY CALC, FBC 13-103.1.2. | | | | | | 7.)PROVIDE A SOILS INVESTIGATION | | | REPORT. | | | | | | 8.)ON THE WALL SECTION, THE BOTTOM | | | OF FOUNDATION SHALL EXTEND NO LESS THAN | | | 12 INCHES BELOW FINISH GRADE, | | | FBC1804.1.3. | | | | | | 9.) SHEET 2 REFERS TO "BUILDING CODE | | | UNLOAD DESIGN CERTIFICATION".REVISE. | | | | | | 10.) SHEET 2, WIND LOAD, SHOWS A MEAN | | | ROOF HEIGHT OF 14'2".BUILDING HEIGHT | | | IS SHOWN AS 60'.REVISE. | | | | | | 11.)SHEET 2, CONNECTOR SCHEDULE, #1, | | | THE NAILING FOR HETAL 16 IS INCONSISTENT | | | WITH THE MINIMUM NUMBER OF NAILS | | | REQUIRED TO OBTAIN THE 1365 UPLIFT. | | | REFER TO THE SIMPSON 2003 CATALOG. | | | | | | 12.)SHEET 2, CONNECTOR SCHEDULE, #2, | | | TWO STRAPS ARE SPECIFIED BUT THE UPLIFT | | | NUMBER REMAINS THE SAME AS FOR ONE | | | STRAP.REVISE. | | | | | | 13.)PROVIDE A WINDOW & DOOR BUCK | | | ATTACHMENT SCHEDULE. | | | | | | 14.)PRODUCT APPROVALS WERE SUBMITTED | | | FOR SLIDING GLASS DOORS.THERE ARE | | | NONE ON THE PLAN. | | | | | | 15.)THE PRODUCT APPROVALS FOR THE | | | SINGLE HUNG WINDOW AND THE SHINGLES | | | ARE EXPIRED.PROVIDE TWO LEGIBLE | | | COPIES OF CURRENT PRODUCT APPROVALS. | | | | | | 16.)PROVIDE TWO COPIES OF THE | | | WINDOW MULLION PRODUCT APPROVAL. | | | | | | 17.)DADE COUNTY NOAS ARE AVAILABLE AT: | | | WWW.MIAMIDADE.GOV (FIND A DEPT, BUILDING | | | CODE, PRODUCT CONTROL). | | | | | | 18.)ADDITIONAL FEES DUE, $364.43 | | | (VALUE ADJUSTMENT). | | | | | | WHEN RESUBMITTING, ALL CHANGES MUST BE | | | CLEARLY MARKED WITH CLOUDS OR TRIANGLES. | | | SUBMIT ONE COPY OF THE OLD SHEETS WITH | | | THE NEW PLANS. | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-02-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-02-24 |
Time |
14:55 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-02-24 |
Time |
14:29 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-19 |
Time |
11:36 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-01-22 |
Time |
09:19 |
Sent To |
B |
|
| Notes |
| 2004-01-22 00:00:00 | | | | DENIED | | | ~~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE PANEL SCHEDULE SHOWS ONE AHU AND | | | THEPLANS SHOW TWO,PLEASE CORRELATE. | | | | | | 2} PLEASE SEE RECEPTS SERVING | | | KITCHEN COUNTERSPACE TO MEET 210.52C- | | | SEC'S 1,2,3,4 AND 5 | | | | | | 3} PLEASE SHOW OUTLET SPACING PER | | | 210.52. 2',6',12' RULE.SEE FAMILY & | | | LIVING ROOMS. | | | | | | 4} SHOW THE LOCATION OF THE SERVICE | | | EQUIPMENT ON THE PLAN.SHOW COMPLIANCE | | | WITH 230.70 CWPB AMMENDMENTS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-11-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-21 |
Time |
14:57 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-11-12 |
Time |
13:47 |
Sent To |
P |
|
| Notes |
| 2003-11-12 00:00:00 | DENIED | | | ~~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | THESE COMMENTS WERE NOT ADDRESSED ON | | | THE PLAN.PLEASE CORRECT AND RESUBMIT | | | FORREVIEW. | | | | | | 1} PLEASE INDICATE THE SIZE OF THE | | | SERVICE CONDUCTORS IN THE RISER(FROM | | | WEATHERHEAD TO METER). | | | | | | 2} THE PANEL SCHEDULE ONLY SHOWS ONE AHU | | | AND THERE ARE TWO SHOWN ON THE PLAN | | | (SEE MECH PLAN).PLEASE REVISE THE LOAD | | | CALCULATION AS WELL. | | | | | | 3} PLEASE SHOW ALL OUTLET SPACING | | | TO MEET 2',6',12' RULE PER 210-52.SEE | | | REVIEWED SET OF PLANS IF YOU HAVE | | | QUESTIONS REGARDING THIS ARTICLE. | | | | | | THESE COMMENTS ARE NEW: | | | | | | SHOW LOCATION OF THE SERVICE EQUIPMENT | | | ON THE PLAN. SHOW COMPLIANCE WITH | | | 230.70 CWPB AMMENDMENTS. | | | | | | COMPLY WITH 210.52(C)(1) IN THE KITCHEN. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-06 |
Time |
10:58 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2003-06-23 |
Time |
06:52 |
Sent To |
P |
|
| Notes |
| 2003-06-23 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE PROVIDE THE FOLLOWING | | | INFORMATION,MAKE NECESSARY CHANGES TO | | | PLANS AND RESUBMIT FOR REVIEW. | | | | | | 1} PLEASE INDICATE THE SIZE OF THE | | | SERVICE CONDUCTORS IN THE RISER. | | | | | | 2} THE PANEL SCHEDULE ONLY SHOWS ONE | | | AHU AND THERE ARE TWO SHOWN ON THE PLAN | | | PLEASE REVISE THE LOAD CALCULATION AS | | | WELL. | | | | | | 3} THE AHU IS LISTED AT 7KW ON THE | | | SCHEDULE AND 5KW ON THE MECHANICAL | | | PLAN,PLEASE CORRELATE. | | | | | | 4} PLEASE SHOW ALL OUTLET SPACING | | | TO MEET 2`,6`,12` RULE PER 210-52.SEE | | | REVIEWED SET OF PLANS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2004-11-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-11-16 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-11-16 |
Time |
13:51 |
Sent To |
P |
|
| Notes |
| 2004-11-16 00:00:00 | SENT TO "P" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2004-10-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-28 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-28 |
Time |
14:25 |
Sent To |
P |
|
| Notes |
| 2004-10-28 00:00:00 | TO KS BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-02-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-19 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-19 |
Time |
11:36 |
Sent To |
E |
|
| Notes |
| 2004-02-19 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-01-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-01-26 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-01-26 |
Time |
17:29 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-12-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-30 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-30 |
Time |
15:56 |
Sent To |
M |
|
| Notes |
| 2003-12-30 00:00:00 | TO PK BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-11-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-06 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-06 |
Time |
10:58 |
Sent To |
E |
|
| Notes |
| 2003-11-06 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-06-19 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-19 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-19 |
Time |
16:53 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-06-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-06-19 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-17 |
Time |
15:23 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-06-03 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-03 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-03 |
Time |
10:14 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2004-03-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-01 |
Time |
13:52 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2004-03-01 |
Time |
13:42 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-01-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-02-27 |
Time |
18:06 |
Rev Time |
0.10 |
| Received By |
pkrauss |
Date |
2004-01-28 |
Time |
12:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2004-01-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-01-26 |
Time |
17:29 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-01-21 |
Time |
14:56 |
Sent To |
E |
|
| Notes |
| 2004-01-21 00:00:00 | PLANS HAVE NOT CHANGED EQUIPMENT SEER # | | | CARLOS TO FAX EQUIPMENT INFORMATION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-30 |
Time |
15:56 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-11-18 |
Time |
17:56 |
Sent To |
B |
|
| Notes |
| 2003-11-18 00:00:00 | PASS PRIVISO | | | NEED A COPY OF ARI PAGE SHOWING | | | EQUIPMENT SEER AT FINAL INSPECTION. | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-11-12 |
Time |
15:29 |
Rev Time |
0.25 |
| Received By |
hmoser |
Date |
2003-07-02 |
Time |
07:04 |
Sent To |
B |
|
| Notes |
| 2003-07-02 00:00:00 | DENIED: | | | | | | EQUIPMENT LISTED ON PLAN SHEET 3 DOES | | | NOT MATCH THE ENERGY CALCULATIONS | | | SUBMITTED.PLEASE REVISE.DUCT LAYOUT | | | OKAY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-30 |
Time |
18:00 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-11-30 |
Time |
18:00 |
Sent To |
|
|
| Notes |
| 2004-11-30 00:00:00 | REVISION OK - SANT. RISER DIAGRAM |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2004-11-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-03 |
Time |
18:05 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-11-03 |
Time |
18:05 |
Sent To |
|
|
| Notes |
| 2004-11-03 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) REVISIONS TO A SIGNED, SEALED, AND | | | DATED PLANS SHALL BE SIGNED, SEALED, AND | | | DATED BY THE ENGINEER OF RECORD. SECTION | | | 104.2.2 | | | 2) SHOW ALL PIPE SIZES ON REVISION. | | | SECTION 104.2.1 | | | 3) REMOVE ALL EXCESS PIPING FROM THE | | | RISER DIAGRAM. (SEE RED LINE AREAS) | | | SECTION 104.2.1 | | | 4) CLEANOUT AT WASH MACHINE SHALL BE | | | LOCATED 4' ABOVE THE FLOOR FOR ACCESS. | | | SECTION 708.10 | | | | | | (SEE RED LINES AND CIRCLES ON SANT. | | | RISER DIAGRAM SHOWING CORRECTIONS TO BE | | | MADE. CORRECT - SIGN/SEAL/DATE | | | REVISION, | | | AND MAKE SURE TITLE BLOCK WITH ALL | | | REQUIRED INFORMATION IS ON REVISION) | | | | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-02-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-28 |
Time |
14:25 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-02-27 |
Time |
18:06 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-02-24 |
Time |
14:55 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-06-23 |
Time |
18:04 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-06-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-01-22 |
Time |
13:45 |
Rev Time |
1.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-06-04 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-17 |
Time |
15:23 |
Rev Time |
1.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-06-04 00:00:00 | 6/4/03 DENIED, NEED A CLEAN COPY OF | | | SURVEY (2) CALL CONTR MM |
|
|