Plan Review Details - Permit 03051969
Plan Review Stops For Permit 03051969
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2003-11-05 Cont ID  
Sent By csiegber Date 2003-12-04 Time 14:16 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2003-11-05 00:00:00USA SHOP DRAWINGS DATED 10/7/03.TWO
 SETS OF SIGNED AND SEALED SHOP DRAWINGS
 ARE REQUIRED, ONE FOR CITY RECORDS AND
 ONE FOR CONTRACTOR FIELD USE.
  
 ALSO, THE DRAWINGS ARE REQUIRED TO BE
 REVIEWED BY THE ENGINEER OF RECORD
 PRIOR TO SUBMITTAL TO THE CITY.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-09-03 Cont ID  
Sent By csiegber Date 2003-11-03 Time 11:03 Rev Time 0.00
Received By hpiskura Date 2003-09-03 Time 12:48 Sent To  
Notes
2003-09-03 00:00:00PERMIT IS ISSUED WITH THE FOLLOWING
 PROVISOS:
  
 THE WORK INCLUDED IN THIS PERMIT IS ONLY
 THAT 7700 SQUARE FEET BUILDING AREA
 SHOWN ON THE PLANS SHEET 100 DATED
 7/29/03.
  
 SHOP DRAWINGS FOR THE METAL BUILDING
 MUST BE PROVIDED TO THE CONSTRUCTION
 SERVICES DIVISION BEFORE ERECTION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-08-05 Cont ID  
Sent By csiegber Date 2003-09-03 Time 11:37 Rev Time 0.00
Received By hpiskura Date 2003-08-04 Time 11:52 Sent To  
Notes
2003-08-04 00:00:003RD CHECKLIST.SEE THE ATTACHED FORM
 RE: FL. STATUTE 553.80(2)(B) AND FEE
 REQUIREMENTS.
  
 THE STAIRS SHOWN AS #122 DO NOT PROVIDE
 A PROTECTED PATH TO THE EXTERIOR OF THE
 BUILDING AS NOTED PREVIOUSLY IN MY
 LISTSDATED 7/02/03 AND 7/24/03.
  
 THE ARCHITECT'S CORRIDOR DESIGN DOES
 NOT COMPLY WITH THAT REQUIRED FOR A
 STAIRSHAFT OR AN "EXIT PASSAGEWAY" AS
 DECLARED IN HIS LETTER DATED 7/29/03.
  
 AN EXIT PASSAGEWAY AS DESCRIBED IN FBC
 1010.3 REQUIRES
 COMPLIANCE WITH FBC 1006.1.3
 AND FBC 1006.1.3.1, FBC TABLE 705.1.2
 AND FBC 704.2.1.2.
  
 1006.1.3 STATES THAT THE STAIRWAY
 ENCLOSURE MAY NOT BE USED FOR ANY OTHER
 PURPOSE THAN MEANS OF EGRESS.
  
 1006.1.3.1 PROHIBITS ANY PENETRATIONS
 EXCEPT FOR THOSE NECESSARY FOR THE
 STAIR SHAFT ITSELF.
  
 THE ARCHITECT HAS AN ELEVATOR LOBBY, A/C
 RETURN FROM THE OFFICES AND AN A/C
 SUPPLY ABOVE THE CEILING WITHIN THE
 CORRIDOR.
  
 THE UL P 204 CEILING DESIGN IS WITHOUT
 STANDING BECAUSE IT IS A ROOF CEILING
 DESIGN, AND NOT A "SHAFT" DESIGN, IN
 ACCORDANCE WITH 704.2.1.2 AS NOTED IN
 FBC 1010.3 CITED ABOVE.EVEN THAT THE
 CEILING DESIGN WAS A FLOOR CEILING
 DESIGN WHICH MORE CLOSELY APPROXIMATES
 THIS SITUATION, IT IS NOT AN ACCEPTABLE
 SOLUTION SINCE ITS INTENT IS TO PROTECT
 THE STRUCTURE ABOVE AND NOT PEOPLE
 WITHIN THE EXIT PASSAGE WAY LIKE A
 SHAFT DESIGN WOULD.PLEASE REVISE AS
 NECESSARY.
  
 FBC TABLE 705.1.2, FOR SHAFTS LESS THAN
 FOUR STORIES, REQUIRES 1 HOUR OPENING
 PROTECTIVES.THE ARCHITECT NOW SHOWS
 DOORS AS "C".SEE FBC 705.1.3.2.1, FOR
 FIRE DOOR CLASSIFICATIONS AS WAS
 PREVIOUSLY NOTED, AND REVISE AS
 NECESSARY.SEE ALSO FBC 705.1.3.4.
  
 THE SIX PAGES TITLED USA CALCULATIONS
 HAVING ONLY A "RECEIVED" DATE STAMP FOR
 AHRENS COMPANIES, ARE NOT SIGNED, SEALED
 OR DATED WITH AN ORIGINAL SIGNATURE AND
 AN EMBOSSED SEAL NOR ANY OF THE PAGES
 NUMBERED.
  
 SEVERAL COPIES OF PAGES OF THE FBC WERE
 INCLUDED WITH THE MOST RECENT SUBMITTAL.
 AMONGST THEM IS PAGE 2.10 WITH THE
 DEFINITION OF NON-COMBUSTIBLE HAVING A
 HIGHLIGHT, A CIRCLE, AN ARROW AND AN
 UNDERLINE.
  
 THE ARCHITECT'S LETTER OF 7/29/03 IN
 ITEM #7 TENDERS THE ARGUMENT THAT
 COMPLIANCE WITH "EITHER OF THE
 FOLLOWING REQUIREMENTS" IS
 SATISFACTORY.I AGREE.NOW PLEASE
 DEMONSTRATE HOW THE FOAM "STRUCTURAL
 BASE" SANDWICHED WITHIN THOSE PANELS IS
 NON-COMBUSTIBLE WHEN TESTED TO E136 IN
 ACCORDANCE WITH THE FIRST CLAUSE OF
 CONDITION #2.I STIPULATE THAT THE
 SURFACING OF ALUMINUM SKIN IS LESS THAN
 1/8" THICK AND PASSES E84.
  
 THE ARCHITECT'S LETTER REFERENCES FBC
 606, 707 AND 2603.4. AT ISSUE IS NOT
 THAT OF INSULATION, OR COMBUSTIBLES IN
 CONCEALED SPACES, BUT THAT OF A
 STRUCTURAL COMPONENT ASSEMBLY REQUIRED
 TO BE NON-COMBUSTIBLE BY TABLE 600.
  
 THIS IS THE THIRD REQUEST FOR THE
 SPECIALTY ENGINEER'S INVESTIGATION OF
 THE COMPONENTS AND CLADDING.
  
 I HAVE REVIEWED THE FACSIMILES FROM
 ALUMASHIELD DATED 7/29/03 WHICH STATES
 THE PRODUCT IS INELIGIBLE TO BE TESTED
 AS NON-COMBUSTIBLE.
  
 PLEASE PROVIDE THE CONSTRUCTION METHOD
 FOR THE THROUGH PENETRATION PROTECTION
 THE EXIT PASSAGEWAY BY THE BAR JOISTS.
 SEE FBC 705.5.1.2.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-07-24 Cont ID  
Sent By hpiskura Date 2003-07-24 Time 10:12 Rev Time 0.00
Received By hpiskura Date 2003-07-24 Time 07:55 Sent To  
Notes
2003-07-24 00:00:00THE INTENDED HORIZONTAL EXTENSION OF
 STAIR #122 DOES NOT COMPLY WITH FBC
 705.1.3.2.1, TABLE 705.1.2 AND 705.1.3.4
 IN THAT THE DOORS ENCLOSING THE "SHAFT
 EXTENSION" ARE SHOWN AS HAVING ONLY A 20
 MINUTE RATING, AND SOME WITHOUT
 CLOSERS, FBC 705.1.3.2.3 AND 705.1.5.
  
 THE STAIR "SHAFT EXTENSION" DOES NOT
 COMPY WITH FBC 1006.1.3.1 IN THAT SHEET
 602 SHOWS A MAJORITY OF THE A/C DUCT
 WORK TO BE LOCATED IN THE "SHAFT
 EXTENSION" AS WELL AS BEING USED FOR A
 RETURN AIR PLENUM.PLEASE REVISE AS
 NECESSARY.
  
 PLEASE PROVIDE A CONSTRUCTION DETAIL FOR
 THE PENETRATION PROTECTION METHOD OF
 THE BAR JOISTS PERPENDICULAR TO THE
 WALLS OF THE STAIR "SHAFT EXTENSION".
 SEE FBC 704.2.1.2 AND FBC 705.5.1.
  
 THE PREVIOUSLY REQUESTED
 CALCULATIONS FOR THE COMPONENTS AND
 CLADDING HAVE NOT BEEN PROVIDED.THE
 DELEGATED ENGINEER'S CALCULATIONS FOR
 THE METAL BUILDING DO NOT SHOW ANY
 INVESTIGATION FOR THE ROOF OR WALL
 SHEATHING.
  
 THE ARCHITECT WHO ASSUMED THE
 RESPONSIBILITY AS DESIGNER OF RECORD
 PROVIDED A NOTE ON SHEET 304 IN THE
 BLOCK TITLED "REQUIRED DESIGN
 PARAMETERS FOR WIND" AND DECLARES A
 MEAN ROOF HEIGHT AS "VARIES".
 THIS IS IN CONFLICT WITH ASCE 7-98
 SECTION 6.5.6.3.1 THAT REQUIRES
 BUILDINGS OF 60' HEIGHT OR LESS TO USE
 VELOCITY PRESSURE Q SUB H WHICH IS
 DEFINED AS MEAN ROOF HEIGHT OR EAVE
 HEIGHT.ASCE 7-98 SECTION 6.3
  
 THIS ISSUE IS EVEN MORE QUESTIONABLE
 WHEN THE DECLARED DESIGN PRESSURES ARE
 WITHIN 100THS OF 1 PSF OF THE NOA'S.
  
 THE INFORMATION PROVIDED FOR THE
 ALUMA-SHIELD WALL PANELS DOES NOT SHOW
 TESTING FOR ASTM E-136 TO DEMONSTRATE
 NON-COMBUSTIBLE (FBC 202) TO COMPLY
 WITH FBC 606 FOR TYPE IVCONSTRUCTION.
  
 THE L1 OF 1 USA SHEET DATED 7/9/03
 NOTES THE ROOF AS UL 90 BUT IS MISSING
 THE UL CONSTRUCTION NUMBER.
  
 SITE PLAN SHEETS 101-105, AND THE FIRE
 ALARM PLANS, ARE NOT SIGNED, SEALED AND
 DATED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-07-02 Cont ID  
Sent By hpiskura Date 2003-07-01 Time 09:01 Rev Time 0.00
Received By hpiskura Date 2003-06-27 Time 13:44 Sent To  
Notes
2003-07-01 00:00:00BEFORE A PERMIT TO CONSTRUCT MAY BE
 ISSUED IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, THE PERMIT PLANS STAMPED
 BY THAT OFFICE AND A COPY OF THE PAID
 RECEIPT ATTACHED TO THE PERMIT
 APPLICATION.CALL 561-233-5025 FOR
 MORE INFORMATION.
  
 1WHAT ARE THE DOTTED LINES IN THE
 REPAIR #134 ON SHEET 301 INTENDED TO
 REPRESENT?
  
 2TWO EXITS ARE REQUIRED FROM REPAIR
 AREA #134 AS SHOWN ON SHEET 301.SEE
 FBC 1004.1.2 AND FBC 1004.1.4.
  
 3AS A CONSEQUENCE OF THE ABOVE
 CONDITION THE DISTANCE FROM THE
 MEZZANINE EXCEEDS 100' FOR GROUP S AS
 PROVIDED FOR IN FBC 1005.7.1.
  
 4STAIR #122 FROM THE SECOND FLOOR
 SHOWN ON SHEET 302 MUST DISCHARGE TO
 THE OUTSIDE OF THE BUILDING.SEE FBC
 1010.
  
 5SHEET 303.THE STAIRS FROM THE
 MECHANICAL ROOM #218 DO NOT COMPLY WITH
 FBC 1007.ALSO, THIS ROOM DOES NOT
 DEFINE AS A MEZZANINE IN ACCORDANCE
 WITH FBC 503.2.3.
  
 6HOW WERE THE PRESSURES FOR THE
 COMPONENTS AND CLADDING DETERMINED THAT
 ARE CALLED OUT ON SHEETS 304 AND 305?
 THE USA CALCULATIONS DO NOT SHOW AN
 INVESTIGATION FOR COMPONENTS AND
 CLADDING.PLEASE PROVIDE THE NECESSARY
 CALCULATIONS, INCLUDING THOSE FOR THE
 ROOF COVERING.NOTE THAT THE ROOF
 COVERING MUST BE DESIGNED TO MEET ONE
 OF STANDARDS IN FBC 1504.3 FOR THE WIND
 PRESSURES IN FBC 1606.
  
 7WHAT IS THE DESIGN LIVE LOAD FOR THE
 SECOND FLOOR OFFICE AREA?
  
 8SHEET L1 OF 1 OF THE USA PLANS
 DECLARES 100# LL FOR THE MEZZANINE.
 THE MINIMUM FOR LIGHT STORAGE IS 125#.
 PLEASE REVISE AS NECESSARY.SEE FBC
 TABLE 1604.
  
 9A NOTE ON SHEET 306 DECLARES THAT THE
 SKYLIGHTS ARE NOT REQUIRED TO BE
 MISSILE IMPACT RESISTANT.THAT IS
 INCORRECT.SEE FBC 2604.1.2.
  
 10SHEET 310.PLEASE PROVIDE DETAILS,
 SPECIFICATIONS FOR THE
 THREE INCH ALUMA-SHIELD PANELS.INCLUDE
 FIRE RESISTANCE AND WIND LOAD
 TEST DATA.SEE FBC 104.2.
  
 11PLEASE PROVIDE THE TEST DATA FOR
 THE EXPOSED VINYL FACED INSULATION IN
 THE METAL BUILDING.SEE FBC 708.3.
  
 12SHOW HOW THE VENTILATION RATE OF 1.5
 CFM / SQUARE FOOT WILL BE ACCOMPLISHED.
 SEE FBC 411.5.4 AND FBC TABLE M403.3
 FOR REPAIR GARAGES.
  
 13THE DOORS SHOWN IN THE SCHEDULE ON
 SHEET308 AS #9, #13 AND #33 ARE
 REQUIRED TO BE 90 MINUTE RATED AND
 LABLELED AND THOSE SHOWN AS #26 AND
 #62, 60 MINUTE LABLELED AND RATED.SEE
 FBC TABLE 705.1.2 FOR OCCUPANCY
 SEPARATIONS AND STAIRS RESPECTIVELY.
 SEE ALSO, FBC 411.5.3 RE: 9, 13, AND 33.
  
 14 SHEET LS-1 CITES THE WRONG EDITION
 OFTHE LIFE SAFETY CODE.SEE THE
 FLORIDA FIRE PREVENTION CODE.
  
 15LS-1, PLEASE CITE THE CITY OF WEST
 PALM BEACH AMENDMENTS TO THE FBC, NOT
 LAKE PARK.
  
 16SHEET 401, FOUNDATION NOTES
 DECLARES CONCRETE DESIGN TO ACI 301-72,
 SEE FBC 1901.1 AND FBC 3502 FOR THE
 CURRENT EDITION OF ACI 318 AND ENSURE
 COMPLIANCE WITH SAME.
  
 17NOA 01-08283.07 FOR THE ROLL UP
 DOORS HAS ILLEGIBLE PAGES.NOA
 00-0508.4 FOR THE KAWNEER DOOR IS
 EXPIRED.
  
 18PLEASE PROVIDE AN ISTALLATION
 SCHEDULE FOR THE SHUTTERS TO BE USED
 INCLUDINGLOCATIONS, SIZES, SPANS,
 FASTENERS AND ANY OTHER PERTINENT
 INFORMATION.
  
 19SECTION 10/318 WINDOW SECTION.
 SHOWTHE METHOD OF FRAMING, BLOCKING,
 ETC THAT WILL EXCEPT THE WINDOWS AND
 DOORS.FBC 104.2.
  
 THE ENERGY CODE IS REQUIRED TO BE SIGNED
 AND SEALED AND PREPARED FOR THE CITY OF
 WEST PALM BEACH JURISDICTION 0604700.
 SEE FBC 13-103.1.1.1.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-07-25 Cont ID  
Sent By dpalmer Date 2003-07-25 Time 14:04 Rev Time 1.00
Received By dpalmer Date 2003-07-25 Time 14:03 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-06-09 Cont ID  
Sent By dpalmer Date 2003-06-09 Time 08:11 Rev Time 0.75
Received By dpalmer Date 2003-06-09 Time 08:11 Sent To  
Notes
2003-06-09 00:00:00************ UNSAT **************
  
 1)NOTE: PLEASE SEE NOTES TO ELECTRICAL,
 MENTIONS, PALM BEACH COUNTY AMENDMENTS,
 PLEASE NOTE, PRODJECT IS UNDER CITY OF
 WEST PALM BEACH.
  
 2)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS
 AT 125% MIN. 215-3/230-42 ETC
  
 3)NOTE: PLEASE SHOW/CLARIFY SHOW WINDOW
 OUTLETS REQ`D PER 210-62
 SIGNS/DISPLAY SIGN/ ADVERTISEMENTS ETC
 REQ`D TO HAVE RECEPTS IN CLOSE PROXIMITY
 W/OUT THE USE OF EXTENSION CORDS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PLAMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2003-08-27 Cont ID  
Sent By mamini Date 2003-08-27 Time 13:03 Rev Time 0.50
Received By mamini Date 2003-08-27 Time 13:03 Sent To  
Notes
2003-08-27 00:00:00PASSED:
 1. SEE PERMIT # 03081243 FOR UNDERGROUND
 UTILITIES AND SITE WORK.
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2003-08-06 Cont ID  
Sent By mamini Date 2003-08-06 Time 14:36 Rev Time 1.00
Received By mamini Date 2003-08-06 Time 14:36 Sent To  
Notes
2003-08-06 00:00:00FAILED:
 1. PLEASE NOTE THAT A SEPARATE PERMIT
 APPLICATION AND FEES FOR UNDERGROUND
 UTILITIES AND SITE WORK IS REQUIRED,
 PLEASE SUBMIT TWO SETS OF CIVIL ONLY,
 INCLUDING POLLUTION/EROSION PLANS
 (SIGNED & SEALED).
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2003-05-28 Cont ID  
Sent By mamini Date 2003-05-28 Time 13:09 Rev Time 1.00
Received By mamini Date 2003-05-28 Time 13:09 Sent To  
Notes
2003-05-28 00:00:00FAILED:
 1. PLEASE NOTE THAT A SEPARATE PERMIT
 APPLICATION AND FEES FOR UNDERGROUND
 UTILITIES AND SITE WORK WILL BE REQUIRED
 2. PLEASE SUBMIT A COPY OF SFWMD PERMIT
 AND CALCULATION EITHER TO US, THE
 CONSTRUCTION SERVICES OR TO PUBLIC
 UTILITIES ENGINEERING SERVICES FOR
 REVIEW AND APPROVAL.
 3. ALL THE WATER AND SEWER CONNECTIONS
 MUST BE COORDINATED WITH CITY OF RIVIERA
 BEACH.
 4. PLEASE NOTE THAT A DDCV ASSEMBLY ON
 PRIVATE FIRE LINE IS REQUIRED.
 5. DRIVEWAY APPROACHES MUST BE PER CITY
 OF WPB REQUIREMENTS, 6" CONCRETE FORM
 CURB-CUT TO PROPERTY LINE.
 6. ANY WORK WITHIN MILITARY TRAIL R.O.W
 REQUIRES PERMIT AND APPROVAL FROM FDOT.
 7. PLEASE CALL RODNEY COMPO FOR OIL /
 WATER SEPARATOR REQUIREMENT/INSTALLATION
 AND INSPECTION AT 837-4051 EXT. 4074
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2003-08-08 Cont ID  
Sent By nmccray Date 2003-08-08 Time 10:15 Rev Time 0.00
Received By nmccray Date 2003-08-08 Time 10:15 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-07-25 Cont ID  
Sent By mcarsill Date 2003-07-25 Time 15:40 Rev Time 0.00
Received By mcarsill Date 2003-07-25 Time 15:40 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2003-06-26 Cont ID  
Sent By mcarsill Date 2003-06-26 Time 16:25 Rev Time 0.00
Received By mcarsill Date 2003-06-26 Time 16:25 Sent To  
Notes
2003-06-26 00:00:001) PLEASE INDICATE HOW FIRE AND
 PARAMEDICAL EQUIPMENT ENTER THRU THE
 SITE VARIOUS GATES.
  
 2) FIRE HYDRANT AND NEW FIRE PROTECTION
 LINE. PLEASE INDICATE SIZE OF LINE.
  
 3) PLEASE EXPLAIN PURPOSE OF ALL THE
 GATES. WHY ARE SO MANY GATES LOCATED
 ON THE PROPERTY.
  
 4) PLEASE PROVIDE MORE DETAILS ON OIL
 TANKS.
  
 5) PLEASE PROVIDE A LIFE SAFETY PLAN
 INDICATING OCCUPANT LOADS, TRAVEL
 DISTANCES, DEAD-ENDS, ETC.
  
 6) WHAT ACTIVITIES WILL OCCUR WITHIN
 REAIR 134.
  
 7) PLEASE INDICATE INTERIOR FINISH
 CLASSIFICATION FOR WALLS AND CEILINGS.
  
 8) SHAFTWAYS ARE TO BE MARKED.
  
 9) PROVIDE SEPARATE PLANS FOR FIRE
 ALARM SYSTEM.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-12-04 Cont ID  
Sent By csiegber Date 2003-12-04 Time 14:16 Rev Time 0.00
Received By csiegber Date 2003-12-04 Time 14:15 Sent To B
Notes
2003-12-04 00:00:00TO HP DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-11-03 Cont ID  
Sent By csiegber Date 2003-11-03 Time 11:03 Rev Time 0.00
Received By csiegber Date 2003-11-03 Time 11:03 Sent To B
Notes
2003-11-03 00:00:00TO HP DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-09-03 Cont ID  
Sent By csiegber Date 2003-09-03 Time 11:37 Rev Time 0.00
Received By csiegber Date 2003-09-03 Time 11:37 Sent To B
Notes
2003-09-03 00:00:00TO HP DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-01 Cont ID  
Sent By alange Date 2003-08-01 Time 13:01 Rev Time 0.00
Received By alange Date 2003-08-01 Time 13:01 Sent To  
Notes
2003-08-01 00:00:00TO COMM BD #40

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-18 Cont ID  
Sent By shernand Date 2003-07-18 Time 11:14 Rev Time 0.00
Received By shernand Date 2003-07-18 Time 11:14 Sent To  
Notes
2003-07-18 00:00:00COMM BOARD #56

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-27 Cont ID  
Sent By sgraham Date 2003-06-06 Time 11:43 Rev Time 0.00
Received By shernand Date 2003-05-27 Time 16:41 Sent To  
Notes
2003-05-27 00:00:00COMM BOARD #14

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-08-04 Cont ID  
Sent By pkrauss Date 2003-08-04 Time 07:41 Rev Time 1.10
Received By pkrauss Date 2003-08-04 Time 07:41 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2003-07-28 Cont ID  
Sent By pkrauss Date 2003-07-26 Time 09:30 Rev Time 2.00
Received By pkrauss Date 2003-07-26 Time 08:52 Sent To  
Notes
2003-07-26 00:00:00PER CONVERSATION WITH MR. DON BOITNOTT
 ON 7-28-03.
 CORRIDOR 121 (FIRE EGRESS HALL) -
 PLEASE PROVIDE THE FOLLOWING INFORMATION
 1) A DETAIL OF THE WALL AND CEILING
 ASSEMBLY.INDICATE WHERE THE WALL
 RATING ENDS.
  
 2) AS PER OUR CONVERSATION THIS IS A
 DUCTED SYSTEM (NO PLENUM), PROVIDE DUCT
 SIZE BETWEEN THE TRANSFER GRILLES.
  
 3) CEILING FIRE DAMPERS REQUIRED AS PER
 2001 FBC(M) 607.2.PER OUR CONVERSATION
 SECTION 705.1.2.2.1, EXCEPTIONS #2,
 EXCEPTIONS EXPLAINED IN THIS SECTION ARE
 FOR WALLS OR PARTITIONS.CEILINGS ARE
 NOT CONSIDERED PARTIONS AS DEFINED IN
 THE 2001 FBC CHAPTER 2.THE EXECPTIONS
 ALSO HAVE TO COMPLY WITH ALL FIVE
 REQUIREMENTS LISTED UNDER #2.
  
 SEE ALSO COMMENTS BY BUILDING & FIRE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-07-01 Cont ID  
Sent By pkrauss Date 2003-06-10 Time 13:59 Rev Time 0.00
Received By pkrauss Date 2003-06-10 Time 13:58 Sent To  
Notes
2003-06-10 00:00:00 
 PLEASE PROVIDE THE FOLLOWING INFORMATION
  
 1.PLEASE CLARIFY PLAN SHEET 603 UNDER
 THE ASHRAE REQUIRMENTS ZONE A IS LISTED
 AS WAREHOUSE AND PLAN SHEET 302 SHOWS
 THIS SPACE REPAIR.THE REQUIREMENTS FOR
 A WAREHOUSE DIFFER FROM A REPAIR GARAGE.
 .05 CFM/SQ FT IS REQUIRED FOR A
 WAREHOUSE WHEREAS 1.5 CFM/PER SQ FT IS
 REQUIRED FOR A REPAIR GARAGE.
  
 2.PLEASE INDICATE WHAT WILL BE STORED
 IN ZONE B, (I.E. COMBUSTIBLES?)
  
 3.PLAN SHEET 601 - AIR CONDITIONING
 LEGEND DUCT SMOKE DETECTOR SEE NOTE 27,
 SHEET 603.THERE IS NOT A NOTE 27 ON
 SHEET 603.PLEASE CLARIFY.
  
 4.PLEASE NOTE DUCT SMOKE DETECTOR
 SHALL BE INSTALLED IN THE SUPPLY AS PER
 2001 FBC(M) 606.2.1.
  
 5.PLAN SHEET 502 INDICATES CONDENSATE
 AND OVERFLOW DRAINS THAT APPEAR TO RUN
 TOGETHER TO DRYWELL.AS PER 2001 FBC
 (M) 307.2.3 & 307.2.4, SECONDARY DRAIN
 TO TERMINATE AT A CONSPICUOUS POINT OR
 A FLOAT SWITCH WILL SUFFICE.

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-08-08 Cont ID  
Sent By kstevens Date 2003-08-08 Time 13:16 Rev Time 2.50
Received By kstevens Date 2003-08-08 Time 13:16 Sent To  
Notes
2003-08-08 00:00:00PASSED/PROVISO
  
 BREAK ROOM SINKS SHALL COMPLY WITH SEC
 11-4.24 AND ALL SUBSECTIONS. (SEE SHEET
 307)
 MANUFACTURE INFORMATION FOR SUMP PUMP
 REQUIRED ON JOB AT TIME OF FINAL PLUMB-
 ING INSPECTION. PUMP SHALL BE LISTED &
 LABELED PER SECTION 303.4
  
  
  
 ---------WHEN RESUBMITTING PLANS--------
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-07-26 Cont ID  
Sent By kstevens Date 2003-07-26 Time 06:59 Rev Time 1.25
Received By kstevens Date 2003-07-26 Time 06:59 Sent To  
Notes
2003-07-26 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) FROM PREVIOUS REVIEW: (COMMENT #5)
 SINKS SHALL COMPLY WITH 11-4.24 AND ALL
 SUBSECTIONS. SHOW KNEE CLEARANCE SECTION
 11-4.24.3, CLEAR FLOOR SPACE 11-4.24.5,
 EXPOSED PIPES AND SURFACES 11-4.24.6, &
 FAUCETS 11-4.24.7. MECHANIC'S BREAK ROOM
 SHALL COMPLY ALSO.
 2) INFORMATIONAL ALL DRINKING FOUNTAINS
 SHALL COMPLY PER SECTION 11-4.1.3(10)(B)
 AS THERE ARE ONLY ONE ON EACH FLOOR AS
 INDICATED BY RESPONSE TO COMMENT #2 OF
 PREVIOUS REVIEW.
 3) FROM PREVIOUS REVIEW: (COMMENT #11)
 MANUFACTURE INFORMATION REQUIRED FOR
 SUMP PUMP. SUBMIT MANUFACTURE CUT SHEETS
 FOR THIS PUMP. 104.2.1 & PLMB. SECTION
 303.4
 4) THE VENT INSTALLED FOR THE EWC IN THE
 REPAIR AREA IS NOT INSTALLED PROPERLY.
 THE TRAP IS AN "S" TRAP AND THE VENT
 SHALL BE SHOWN AS A STACK VENT FOR THE
 EWC.
 5) TABLE 906.1 THE TRAP FOR THE TRENCH
 DRAIN IN THE REPAIR AREA IS OVER THE
 MAXIMUM ALLOWABLE DISTANCE FROM THE VENT
 PLACE VENT IN WALL AS CLOSE AS POSSIBLE
 AND PUT TRAP 12' FROM VENT. AT TOP OF
 THE TRAP PUT IN A CLEANOUT AND TEE OFF
 TRAP RISER TO TRENCH DRAIN. SEE ATTACHED
 SHEET FOR EXAMPLE.
 6) THERMAL EXPANSION CONTROL IS REQUIRED
 PER SECTION 607.3.2
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-06-16 Cont ID  
Sent By kstevens Date 2003-06-16 Time 17:34 Rev Time 2.00
Received By kstevens Date 2003-06-16 Time 17:34 Sent To  
Notes
2003-06-16 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
 FBC-2001 AMENDMENTS TO THE
 FLA. BLDG. CODE, CHAPTER 1,
 AMENDMENTS TO BLDG. ECT.
  
 1) CONTACT RODNEY COMPO, INDUSTRIAL PRE-
 TREATMENT, ENVIRONMENTAL COMPLIANCE FOR
 SIZING OF SAND/OIL INTECEPTOR. WASTE ORD
 # 2938-96. (561) 837-4074
 2) SUBMIT CALCULATION FOR MINIMUM FIX-
 TURE REQUIREMENTS PER TABLE 1003.1, AND
 TABLE 403.1.
 3) SHT 303 SHOW CLEAR FLOOR SPACE AND 5'
 TURINING CIRCLE PER SEC 11-4.22.3
 4) SHT 307 DETAIL #3, SHOWER - SHOW CON-
 TROL HEIGHT. 11-4.21.5, AND CURB SECTION
 11-4.21.2.7
 5) SHT 307 DETAILS #'S 7 & 8, SINKS
 SHALL COMPLY WITH 11-24 AND ALL SUB-
 SECTIONS. PLEASE SHOW ON DETAIL.
 6) SHT 307 DETAIL #9, DRINKING FOUNTAIN,
 PROVISIONS SHALL BE MADE FOR THOSE WHO
 HAVE DIFFICULTY BENDING OR STOOPING. SEC
 11-4.1.3(10).
 7) SHT 502 SANT. RISER DIAGRAM DOES NOT
 MEET CODE REQUIREMENTS. EWC IN REPAIR
 AREA #134 NOT VENTED. URNAL & LAV NOT
 VENTED IN MECH. BATH #106. EWC NOT VENT-
 ED OUTSIDE TOILET ROOMS #'S 125 & 126.
 8) SUBMIT A WATER RISER DIAGRAM.
 9) SUBMIT A COMPRESSED AIR RISER DIAGRAM
 10) SUBMIT A CONDENSATE RISER DIAGRAM.
 11) SHT 502 SUBMIT MANUF. INFO FOR SUMP
 PUMP. SEC 104.2.1 (FOR COMMENT # 8, 9,
 10, & 11).
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop Z ZONING
Rev No 1 Status P Date 2003-06-06 Cont ID  
Sent By mmclean Date 2003-06-05 Time 16:42 Rev Time 1.00
Received By sgraham Date   Time   Sent To I
Notes
2003-06-05 00:00:006/5/03 PASS ZONING (RANDALL EXT 8365)


Account Summary | Usage Policy | Privacy Policy