Plan Review Details - Permit 03051812
Plan Review Stops For Permit 03051812
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-10-03 Cont ID  
Sent By csiegber Date 2004-08-09 Time 13:27 Rev Time 0.25
Received By lsmith Date 2003-10-03 Time 16:13 Sent To  
Notes
2003-10-03 00:00:00CHANGE 2ND FLOOR ATTIC ACCESS

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-07-02 Cont ID  
Sent By kstevens Date 2003-09-10 Time 17:41 Rev Time 3.00
Received By lhatten Date 2003-06-29 Time 17:21 Sent To  
Notes
2003-07-02 00:00:00REVIEWED & STAMPED PLANS 06/29/2003
 PRINT CARD 07/02/2003

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2004-08-19 Cont ID  
Sent By btrobaug Date 2004-08-19 Time 14:21 Rev Time 0.50
Received By btrobaug Date 2004-08-19 Time 14:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-08-06 Cont ID  
Sent By btrobaug Date 2004-08-06 Time 07:42 Rev Time 0.50
Received By btrobaug Date 2004-08-06 Time 07:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-10-27 Cont ID  
Sent By csiegber Date 2004-07-29 Time 08:25 Rev Time 0.50
Received By btrobaug Date 2003-10-27 Time 16:35 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-09-05 Cont ID  
Sent By csiegber Date 2003-10-24 Time 12:36 Rev Time 0.50
Received By btrobaug Date 2003-09-05 Time 13:41 Sent To P
Notes
2003-09-05 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 AND RESUBMIT FOR REVIEW.
  
 CORRECT THE ARCHITECTS TITLE BLOCK TO
 COMPLY WITH 61G1-16.004.
  
 THE RISER DIAGRAM SHOWS THE PANEL BEING
 FED FROM THE METER AND THE PLAN
 INDICATES A METER MAIN,PLEASE CORRELATE.
  
 THE RECEPTACLE IN THE POWDER ROOM MUST
 BE GFI PROTECTED PER 210.8(A)(1).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-06-09 Cont ID  
Sent By csiegber Date 2003-08-29 Time 15:52 Rev Time 0.50
Received By btrobaug Date 2003-06-09 Time 08:37 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2004-08-09 Cont ID  
Sent By csiegber Date 2004-08-09 Time 13:27 Rev Time 0.00
Received By csiegber Date 2004-08-09 Time 13:27 Sent To B
Notes
2004-08-09 00:00:00TO LS DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-08-06 Cont ID  
Sent By csiegber Date 2004-08-06 Time 09:05 Rev Time 0.00
Received By csiegber Date 2004-08-06 Time 09:05 Sent To B
Notes
2004-08-06 00:00:00TO LS DESK/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-07-29 Cont ID  
Sent By csiegber Date 2004-07-29 Time 08:25 Rev Time 0.00
Received By csiegber Date 2004-07-29 Time 08:25 Sent To E
Notes
2004-07-29 00:00:00TO
 TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-10-24 Cont ID  
Sent By csiegber Date 2003-10-24 Time 12:36 Rev Time 0.00
Received By csiegber Date 2003-10-24 Time 12:36 Sent To E
Notes
2003-10-24 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-29 Cont ID  
Sent By csiegber Date 2003-08-29 Time 15:52 Rev Time 0.00
Received By csiegber Date 2003-08-29 Time 15:52 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-08 Cont ID  
Sent By shernand Date 2003-07-07 Time 16:56 Rev Time 0.00
Received By sthyng Date 2003-07-07 Time 16:56 Sent To B
Notes
2003-07-08 00:00:00TO LH DESK
2003-07-07 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-27 Cont ID  
Sent By shernand Date 2003-05-27 Time 08:56 Rev Time 0.00
Received By shernand Date 2003-05-27 Time 08:56 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-06-21 Cont ID  
Sent By jleech Date 2003-06-19 Time 19:12 Rev Time 0.50
Received By hmoser Date 2003-06-21 Time 09:52 Sent To B
Notes
2003-06-21 00:00:00PASS PRIVISO
 NEED RETURN AIR IN MASTER BEDROOM
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6752

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-10-30 Cont ID  
Sent By kstevens Date 2003-10-30 Time 17:34 Rev Time 0.50
Received By kstevens Date 2003-10-30 Time 17:29 Sent To  
Notes
2003-10-30 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-09-10 Cont ID  
Sent By btrobaug Date 2003-10-27 Time 16:35 Rev Time 0.50
Received By kstevens Date 2003-09-10 Time 17:40 Sent To B
Notes
2003-09-10 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 AMENDMENTS, CHAPTER
 ONE
 FLORIDA ADMINISTRATIVE CODE
  
 1) SANITARY RISER DIAGRAM DOES NOT MEET
 CODE REQUIREMENTS.
 A) A STANDPIPE IS REQUIRED FOR WASH
 MACHINE. SECTION 802.4
 B) A TRAP IS REQUIRED FOR WASH MACHINE.
 SECTION 1002.1
 C) LAUNDRY SINK IS NOT VENTED. SECTION
 901.2.1
 2) 61G1-16.004 ARCHITECT'S LICENSE IS
 REQUIRED ON EACH SHEET.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-06-19 Cont ID  
Sent By btrobaug Date 2003-09-05 Time 13:45 Rev Time 0.25
Received By jleech Date 2003-06-19 Time 19:12 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-27 Cont ID  
Sent By shernand Date 2003-05-27 Time 08:56 Rev Time 1.00
Received By mmclean Date   Time   Sent To E
Notes
***NONE***