| Plan Review Stops For Permit 03051683 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-06-23 |
Time |
09:40 |
Rev Time |
0.95 |
| Received By |
jwitmer |
Date |
2003-06-23 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2003-06-23 00:00:00 | | | | *** ISSUED PERMIT*** | | | -PLAN REVIEW HISTORY- | | | | | | PERMIT# 03051683 | | | ADDRESS: 1801 S FLAGLER/ 511 | | | CONT: JOSEPH A JORY | | | TELL # (561)818-6472 | | | | | | THE ATTACHED COMMENTS ARE PART OF THE | | | PERMIT AND PLAN REVIEW PACKAGE AND ARE | | | NOT TO BE REMOVED FROM THE ISSUED SET OF | | | PLANS.104.2.1.2 ADMINISTRATIVE CODE. | | | | | | *****PROVISO***** | | | 1) CONTRACTOR PULLS VALUES OUT OF PERMIT | | | VALUE FOR CABINETS, COUNTER TOPS, | | | FLOORING & PAINTING/ UNDER $254,000.00 | | | OF VALUE EXCEPTION TO SS 481 FOR | | | LICENSUR(SEALED PLANS). | | | | | | 2) 609 .TYPE I TYPE II BUILDINGS, FIRE | | | RETARDANT TREATED WOOD IF USED IN WALLS. | | | | | | JIM WITMER | | | (561)805-6715 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-06-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-06-23 |
Time |
09:34 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2003-06-19 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2003-06-19 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03051683 | | | ADD: 1801 S FLAGLER DR # 511 | | | CONT: JOSEPH A JORY | | | TEL: (561)818-6472 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | ACTION: DENIED | | | | | | 1)ALL INFORMATION, DRAWINGS, SPECIF- | | | ICATIONS AND ACCOMPANYING DATA SHALL | | | BEAR THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN. | | | CITY AMENDMENTS 104.2.1 | | | | | | 2) FL S.S. 481.229(C) REQUIRES A DESIGN | | | PROFESSIONAL (ARCHETECT OR ENGINEER) | | | FOR WORK WITH A VALUE IN EXCESS OF | | | $24,999.99.PLANS SHALL REQUIRE SIGNATURE | | | AND SEAL OF DESIGN PROFESSIONAL. | | | | | | 3) PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 4) PLAN DO NOT INDICATE THE TYPE OF CONS | | | TRUCTION FOR THE BUILDING? AT THE MINI- | | | MUM THIS BUILDING ISA TYPE II CONSTRUC- | | | TION, 609.1 REQUIRES ANY WOOD FRAMING | | | MEMBERS TO BE FIRE RETARDANT TREATED | | | WOOD! | | | | | | 5) FL ACCESSIBILITY CODE 11-4.1.6 | | | ALTERATIONS(B) IF EXISTING ELEMENTS, | | | SPACES, OR COMMON AREAS ARE ALTERED, | | | THEN EACH SUCH ALTERED AREA SHALL COMPLY | | | WITH THE APPLIABLE PROVISIONS . | | | ONE BATHROOM DOOR TO COMPLY WITH SECTION | | | 11-4.22.2 29" CLEAR OPENING. | | | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | JIM WITMER | | | BUILDING PLAN REVIEW | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-06-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-06-02 |
Time |
14:34 |
Rev Time |
1.50 |
| Received By |
sthyng |
Date |
2003-06-10 |
Time |
18:19 |
Sent To |
|
|
| Notes |
| 2003-06-11 00:00:00 | *****CORRECTIONS******* | | | | | | 1.)PLANS WITH AN ARCHITECT'S BLOCK | | | ARE REQUIRED TO BE SIGNED, SEALED AND | | | DATED FS481.221. | | | | | | 2.)AN ARCHITECT MUST BE LICENSED IN | | | FLORIDA FS 481.203, 481.213. | | | | | | 3.)SEPARATE PERMITS REQUIRED. | | | | | | 4.)TENANT SPACES ARE REQUIRED TO BE | | | SEPARATED BY A 1-HR FIRE RESISTANCE FBC | | | 704.3.1.WHERE PARTITION WALLS | | | PERPENDICULAR TO TENANT SEPARATION WALLS | | | ARE REMOVED, THE PATCHING OF THE TENANT | | | SEPARATION WALL MUST COMPLY WITH THE | | | 1-HR FIRE RESISTANCE.SHOW ON THE PLAN. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-06-19 |
Time |
09:37 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-06-18 |
Time |
09:02 |
Sent To |
B |
|
| Notes |
| 2003-06-19 00:00:00 | PROVISO | | | ~~~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE NOTE THE FOLLOWING COMMENTS: | | | | | | 1} ON THE ISSUE OF THE OLDER PANEL AND | | | HAVING PROBLEMS FINDING AN ARC FAULT | | | BREAKER,THE RESOLUTION IS TO SET A | | | SMALL SUB-PANEL TO ACCOMMODATE THE | | | INSTALLATION OF BREAKERS AS NEEDED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-05-23 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-12 |
Time |
10:08 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-05-23 |
Time |
11:35 |
Sent To |
P |
|
| Notes |
| 2003-05-23 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE ADDRESS THE FOLLOWING COMMENTS | | | AND RESUBMIT FOR REVIEW. | | | | | | 1} ADD A RECEPTACLE TO IN THE BEDROOM TO | | | COMPLY WITH 210-52(A)(1). | | | | | | 2} PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CIRCUITS ON PANEL | | | SCHEDULE OR NOTE ON PLANS FOR BRANCH | | | CIRCUIT PROTECTION. PER 210-12. | | | | | | NOTE: PLEASE NOTE KITCHEN COUNTER- | | | -SPACE RECEPT SPACING SHALL MEET ART; | | | 210-52C 1,2,3,4,AND 5. | | | | | | NOTE: PLEASE NOTE THAT ALL PLANS | | | DRAWN BY AN ARCHITECT/ENGINEER CONTAIN- | | | ING A TITLE BLOCK, MUST BE SIGNED, | | | DATED AND SEALED BY THE ARCH/ENGINEER | | | OF RECORD. PER FS/FAC 481.221 & 471.025 | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-06-12 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-12 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-12 |
Time |
10:08 |
Sent To |
E |
|
| Notes |
| 2003-06-12 00:00:00 | BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-05-22 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-22 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-22 |
Time |
15:17 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-06-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-30 |
Time |
13:10 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2003-06-02 |
Time |
14:26 |
Sent To |
B |
|
| Notes |
| 2003-06-02 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR REVIEW | | | | | | 1.NOTE ON PLAN SHEET 6 INDICATES AHU | | | TO BE REPLACED, SOME GRILLES MAY HAVE TO | | | BE RELOCATED. | | | | | | 2.PROVIDE THE ABOVE INFORMATION WITH | | | MECHANICAL PERMIT APPLICATION. | | | | | | 3.SEE PLUMBING & ELECTRICAL COMMENTS | | | ON COMPLIANCE WITH FS/FAC 481.221 & | | | 471.025. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-23 |
Time |
09:27 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-06-23 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2003-06-23 00:00:00 | CONTRACT PRICE BELOW $25.000 - (SEE | | | APPLICATION) - CONTRACTOR INDICATED THAT | | | THERE IS A 2" TRAP FOR SHOWER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-06-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-20 |
Time |
10:36 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-06-20 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2003-06-20 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLA. STATUTES | | | FBC-2001 AMENDMENTS. ADMIN. | | | CODE, CHAPTER 1 | | | | | | 1) ALL WORK $25,000 AND OVER REQUIRES A | | | DESIGN PROFESSIONAL. PLANS SHALL BE | | | SIGNED, SEALED, DATED, AND HAVE A TITLE | | | BLOCK THAT HAS THE FOLLOWING INFORMATION | | | NAME OF FIRM, ADDRESS, TELEPHONE NUMBER | | | AND FIRM LICENSES NUMBER. | | | FLA S.S. 481.299(C) | | | FLA S.S. 61G15-23.002 OR 61G16.003 | | | 2) ALL INFORMATION, DRAWINGS, SPECIFI- | | | CATIONS AND ACCOMPANING DATA SHALL BEAR | | | THE NAME AND SIGNATURE OF THE PERSON RE- | | | SPONSIBLE FOR THE DESIGN. SEC 104.2.1 | | | 3) SIGNED, SEALED, & DATED LETTER FROM | | | AN ENGINEER REQUIRED FOR SHOWER IF 2" | | | SANITARY DRAIN IS NOT AVAILABLE. A TITLE | | | BLOCK COMPLYING WITH 61G15-23.002(2). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-05-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-05-23 |
Time |
11:44 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-05-30 |
Time |
13:05 |
Sent To |
M |
|
| Notes |
| 2003-05-30 00:00:00 | DENIED | | | REFERENCE: FLORIDA STATUTES. | | | | | | 1) 61G1-16.003 THE PERSONAL SEAL, SIG- | | | NATURE AND DATE OF THE ARCHITECT SHALL | | | APPEAR ON ALL ARCHITECTURAL DOCUMENTS TO | | | BE FILED FOR PUBLIC RECORD. | | | 2) 61G1-16.004(2) FIRM LICENSE NUMBER | | | REQUIRED ON TITLE BLOCK. | | | 3) 2" DRAIN REQUIRED FOR SHOWER. IF ONLY | | | 1-1/2" DRAIN IS AVAILABLE, A LETTER FROM | | | AN ENGINEER, SIGNED AND SEALED, INDICAT- | | | ING THAT THE 1-1/2" DRAIN WILL BE SUFFI- | | | CIENT SHALL BE REQUIRED ON THE JOBSITE | | | AT TIME OF ROUGH INSPECTION. LETTER | | | SHALL BE DATED AND HAVE A TITLE BLOCK | | | COMPLYING WITH 61G15-23.002(2). | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|