Plan Review Details - Permit 03051669
Plan Review Stops For Permit 03051669
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-06-16 Cont ID  
Sent By sthyng Date 2003-06-16 Time 14:07 Rev Time 1.00
Received By sthyng Date 2003-06-16 Time 14:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-06-11 Cont ID  
Sent By shernand Date 2003-06-16 Time 13:25 Rev Time 2.00
Received By sthyng Date 2003-06-10 Time 15:31 Sent To  
Notes
2003-06-10 00:00:00********CORRECTIONS*******
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)ADDITIONAL FEES REQUIRED, $3.80
  
 2.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE
 STAMPED, AND THE RECEIPT ATTACHED TO
 THE APPLICATION.233-5025
  
 3.)THE STRUCTURAL NOTES REFER TO
 THE ELEVATIONS FOR DESIGN PRESSURES;
 NOT ON ELEVATIONS.
  
 4.)TWO COPIES OF ALL SHUTTERS, DOORS,
 WINDOWS, MULLIONS, AND IMPACT PROTECTION
 PRODUCT APPROVALS REQUIRED.COPIES
 MUST BE COMPLETE, LEGIBLE, AND STAPLED.
 IF PRODUCT APPROVALS ARE NOT SUBMITTED
 WITH THE RESUBMITTAL, SEPARATE PERMITS
 WILL BE REQUIRED FOR THOSE ITEMS.
  
 5.)THERE IS A CONFLICT BETWEEN THE
 PLAN AND THE PRODUCT APPROVALS
 SUBMITTED.THE PRODUCT APPROVALS MUST
 BE FOR THE ITEMS TO BE INSTALLED.
 EITHER CHANGE THE PLAN OR SUBMIT
 DIFFERENT PRODUCT APPROVALS.
  
 6.)IF STORM PANELS ARE TO BE
 INSTALLED, SUBMIT A STORM PANEL
 INSTALLATION SCHEDULE.IF ONE IS NOT
 SUBMITTED AT THE TIME OF RESUBMITTAL,
 A SEPARATE PERMIT FOR STORM PANELS WILL
 BE REQUIRED.SEE ATTACHED.
  
 7.)PROVIDE ATTACHMENT DETAIL FOR
 THE SCREEN ON THE SCREEN PORCH.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-06-06 Cont ID  
Sent By shernand Date 2003-06-04 Time 15:22 Rev Time 0.33
Received By btrobaug Date 2003-06-06 Time 09:36 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-06-16 Cont ID  
Sent By shernand Date 2003-06-16 Time 13:25 Rev Time 0.00
Received By shernand Date 2003-06-16 Time 13:25 Sent To B
Notes
2003-06-16 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-04 Cont ID  
Sent By shernand Date 2003-06-04 Time 15:21 Rev Time 0.00
Received By shernand Date 2003-06-04 Time 15:21 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-22 Cont ID  
Sent By mmclean Date 2003-06-04 Time 12:15 Rev Time 0.00
Received By shernand Date 2003-05-22 Time 09:59 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-06-09 Cont ID  
Sent By btrobaug Date 2003-06-06 Time 09:56 Rev Time 0.15
Received By pkrauss Date 2003-06-09 Time 14:03 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-06-04 Cont ID  
Sent By shernand Date 2003-05-22 Time 09:59 Rev Time 1.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***