| Plan Review Stops For Permit 03051571 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-06-27 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-06-27 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-06-27 00:00:00 | REVISIONS DATED 6/25/03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-05-30 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-05-30 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-05-30 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-07-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-07-07 |
Time |
11:12 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-07-07 |
Time |
11:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-05-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-05-21 |
Time |
16:23 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-05-21 |
Time |
16:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-07-09 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-07-09 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-07-09 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2003-07-09 00:00:00 | REVISION 6-26-03 NAM |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2003-06-03 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-06-03 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-06-03 |
Time |
13:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-07-25 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-25 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-25 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2003-07-25 00:00:00 | CALLED CONTRACTOR NOT TITLE BLOCK | | | FILED UNDER "F"ALANGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-06-18 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-18 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-18 |
Time |
15:46 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-05-21 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-21 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-21 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2003-05-21 00:00:00 | COMM BOARD #18 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-07-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-07-07 |
Time |
07:45 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2003-07-07 |
Time |
07:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-06-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-06-19 |
Time |
13:12 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-06-19 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2003-06-19 00:00:00 | SUBMITTAL LETTER & PLAN ADDRESSING | | | FIRE DAMPER IN CORRIDOR.PLANS APPROVED |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-05-23 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-18 |
Time |
15:47 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2003-05-23 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2003-05-23 00:00:00 | DENIED: | | | PLEASE CLARIFY THE FOLLOWING INFORMATION | | | | | | PLAN SHEET 1 INDICATES A FIRE RATED | | | PARTITION BETWEEN THE CORRIDOR & OPEN | | | OFFICE #213. THE MECHANICAL PLANS (#4) | | | DO NOT INDICATE FIRE DAMPERS (NEW OR | | | EXISTING) PENETRATING THIS PARTITION. | | | PLANS INDICATE FIRE DAMPERS ONLY AT | | | THE MECHANICAL ROOM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2003-07-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-07 |
Time |
18:34 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-07-07 |
Time |
18:34 |
Sent To |
|
|
| Notes |
| 2003-07-07 00:00:00 | NO PLUMBING REVISIONS SUBMITTED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-06-17 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-17 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-17 |
Time |
15:49 |
Sent To |
P |
|
| Notes |
| 2003-06-17 00:00:00 | KSTEVENS PASSED ON 6/7/03. |
|
|