| 2003-05-29 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 03051518 |
| | ADD: 641 34TH ST |
| | CONT: NEWBOLD CONST |
| | TEL: (561)254-0805 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | 1) THE R-30 INSULATION IS 12" THICK, THE |
| | PROPOSED ROOF TRUSSES ARE 2"X6", ADDI- |
| | ITIONAL INFORMATION REQUIRED FOR HOW THE |
| | INSULATION (R-30) WILL FIT? |
| | |
| | 2) INDICATE ON EITHER THE SURVEY THE |
| | EXISTING CARPORT OR ON THE FLOOR PLAN |
| | THE DISTANCE FROM THE PROPERTY LINE? |
| | THE SURVEY AND THE EXISTING FLOOR PLAN |
| | DO NOT MATCH? |
| | |
| | 3) THE PLAN INDICATES THAT THE LEDGER IS |
| | TO BE ANCHORED TO THE EXISTING BUILDING |
| | AT 2'-0" O.C., ARE THE STUDS IN THE |
| | EXISTING DWELLING LAID OUT AT 24"O.C.? |
| | |
| | 4)FL. BLD CODE 1606.1.7 THE FOLLOWING |
| | INFORMATION RELATED TO WIND SHALL BE |
| | SHOWN ON THE CONSTRUCTION DRAWINGS, |
| | 1)- BASIC WIND SPEED, MPH |
| | 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| | CATEGORY |
| | 3)- WIND EXPOSURE |
| | 4)- INTERNAL PRESSURE COEFFICIENT, |
| | 5)- COMPONENTS & CLADDING, THE DESIGN |
| | WIND PRESSURES IN TERMS OF PSF. |
| | |
| | 5)1507.3.8. ASPHALT SHINGLES LOW |
| | SLOPE ROOFING, UNDERLAYMENT APPLICATION |
| | FOR ROOF SLOPES FROM 2:12 UP TO 4:12, |
| | UNDERLAYMENT SHAL BE A MINIMUM OF TWO |
| | LAYERS APPLIED AS FOLLOWS: |
| | 1) STARTING AT THE EAVE, A 19-INCH |
| | STRIP OF UNDERLAYMENT SHALL BE APPLIED |
| | PARALLEL WITH THE EAVE AND FASTENED |
| | SUFFICIENTLY TO STAY IN PLACE. |
| | 2) STARTING AT THE EAVE, 36-INCH-WIDE |
| | STRIPS OF UNDERLAYMENT FELT SHALL BE |
| | APPLIED OVER LAPPING SUCCESSIVE SHEETS |
| | 19 INCHES AND FASTENED SUFFICIENTLY TO |
| | STAY IN PLACE. |
| | |
| | 6) 1403.1.6 IN ORDER TO PROVIDE FOR |
| | INSPECTION FOR TERMITE INFESTATION, |
| | CLEARENCE BETWEEN EXTERIOR WALL COVERING |
| | AND FINAL EARTH GRADE ON THE EXTERIOR OF |
| | A BUILDING SHALL NOT BE LESS THAN 6". |
| | |
| | 7)BEFORE A PERMIT TO CONSTRUCT, MAY |
| | BE ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | LOOK FOR COMMENTS BY THE OTHER PLAN |
| | REVIEW DISCIPLINES THAT MAY BE WRITTEN |
| | ON THE APPLICATION, PLANS, OR ATTACHED |
| | SEPARATELY. WHEN RESUBMITTING PLANS |
| | PLEASE CLEARLY INDICATE THE REVISION AND |
| | REMOVE AND REPLACE ANY PAGES AS NECESS- |
| | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH |
| | THE PLANS WHEN RESUBMITTING PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN |
| | BE FOUND, WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | JIM WITMER |
| | BUILDING PLAN REVIEW |
| | TEL: (561)659-8096 X 8412 |
| | FAX: (561)659-8026 |