Plan Review Details - Permit 03051415
Plan Review Stops For Permit 03051415
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-09-29 Cont ID  
Sent By hpiskura Date 2003-09-29 Time 16:34 Rev Time 0.00
Received By hpiskura Date 2003-09-29 Time 16:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-06-19 Cont ID  
Sent By hpiskura Date 2003-06-19 Time 11:08 Rev Time 0.00
Received By hpiskura Date 2003-06-19 Time 11:08 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-05-19 Cont ID  
Sent By dpalmer Date 2003-05-19 Time 18:53 Rev Time 1.00
Received By dpalmer Date 2003-05-19 Time 18:53 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-09-09 Cont ID  
Sent By nmccray Date 2003-09-09 Time 09:23 Rev Time 0.00
Received By nmccray Date 2003-09-09 Time 09:23 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2003-06-13 Cont ID  
Sent By mcarsill Date 2003-06-13 Time 09:14 Rev Time 0.00
Received By mcarsill Date 2003-06-13 Time 09:14 Sent To  
Notes
2003-06-13 00:00:001) ALL DEMOLTION, CONSTRUCTION, AND
 RENOVATION ACTIVITIES TO COMPLY WITH
 NFPA 241.
  
 2) NO WORK IS TO INTERFERE WITH ANY
 EXIT ACCESS, EXITING, OR EXIT DISCHARGE.
  
 3) ALL COMBUSTIBLE WASTE IS TO BE
 REMOVED FROM THE BUILDING DAILY.
  
 4) NON FIRE RATED VISQUEEN OR OTHER
 NON APPROVED MATERIALS SHALL NOT BE HUNG
 FROM THE CEILING.
  
 5) ALL REQUIRED FIRE SPRINKLER AND
 FIRE ALARM SYSTEMS ARE TO REMAIN IN
 OPERATION.
  
 6) NO CUTTING OR WELDING OPERATIONS
 ALLOWED TO BE DONE WITHOUT APPROVAL
 OF THE BUREAU OF FIRE PREVENTION.
  
 7) ALL NEW STAIRS AND RAMPS ARE REQUIRED
 TO HAVE HANDRAILS ON BOTH SIDES.
  
 8) ALL NEW COOLERS AND FREEZERS SHALL
 BE FIRE SPRINKLER PROTECTED.
  
 9) NO TRIPPING HZARDS SHALL EXIST
 DURING FLOOR WORK.
  
 10) PROPER VENTILATION IS TO BE
 PROVIDED DURING OPERATION OF GASOLINE
 POWERED EQUIPMENT TO AVOID CARBON
 MONOXIDE.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-29 Cont ID  
Sent By csiegber Date 2003-08-29 Time 11:34 Rev Time 0.00
Received By csiegber Date 2003-08-29 Time 11:34 Sent To  
Notes
2003-08-29 00:00:00ON COMM BD #56

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-19 Cont ID  
Sent By shernand Date 2003-05-19 Time 16:16 Rev Time 0.00
Received By csiegber Date 2003-08-29 Time 11:30 Sent To  
Notes
2003-05-19 00:00:00COMM BOARD #45

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-05-23 Cont ID  
Sent By pkrauss Date 2003-05-23 Time 12:50 Rev Time 0.50
Received By pkrauss Date 2003-05-23 Time 12:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-09-30 Cont ID  
Sent By kstevens Date 2003-09-30 Time 16:21 Rev Time 1.50
Received By kstevens Date 2003-09-30 Time 16:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-06-12 Cont ID  
Sent By kstevens Date 2003-06-12 Time 11:31 Rev Time 2.00
Received By kstevens Date 2003-06-11 Time 18:49 Sent To  
Notes
2003-06-12 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 11
  
 1) SHT A-1 PLEASE SHOW CLEAR FLOOR SPACE
 FOR WOMEN'S HDCP STALL, (#105), AND MENS
 HDCP STALL, (#120) PER SECTION 11-4.22.3
 2) SHT PB-1 PLUMBING NOTES #5, AIR CHAM-
 BERS ARE NOT APPROVED. PLEASE DELETE RE-
 FERENCE.
 3) SEPARATE GAS PERMIT REQUIRED.
 4) SHT PD-1 ANY PLUMBING PIPING DEMO'ED
 SHALL BE INSPECTED PRIOR TO COVERING.
 5) SHT P-1 SINK P-7 IN LOUNGE, (#115),
 SHALL COMPLY WITH SECTION 11-4.24 & ALL
 SUBSECTIONS. PLEASE PROVIDE A DETAIL.
 6) SHT P-1 KEYNOTES #11, NEW FILTERS
 SHALL BE NSF APPROVED. PLEASE SUBMIT
 MANUF. INFORMATION.
 7) SHT P-2 WATER RISER ISOMETRIC, ALL
 WATER HAMMER ARRESTORS SHALL BE LOCATED
 NEAR THE FIXTURES, IN AN "EFFICTIVE
 RANGE", NOT IN THE CEILING AT THE TOP OF
 THE DROPS. PDI-WH 201 & MANUF. INSTALL-
 ATION INSTRUCTIONS.
 8) SHT P-5 DETAIL 8/P-5, CONDENSATE TRAP
 DETAIL. FLOOR DRAIN NOT AN APPROVED IN-
 DIRECT WASTE RECEPTOR. FLOOR SINK OR HUB
 DRAIN REQUIRED. SECTIONS 802.3 & 802.3.2
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692