Plan Review Details - Permit 03051415
| Plan Review Stops For Permit 03051415 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-09-29 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-09-29 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-09-29 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-06-19 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-06-19 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-06-19 |
Time |
11:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-05-19 |
Time |
18:53 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-05-19 |
Time |
18:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-09-09 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-09-09 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-09-09 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-06-13 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-06-13 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-06-13 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2003-06-13 00:00:00 | 1) ALL DEMOLTION, CONSTRUCTION, AND | | | RENOVATION ACTIVITIES TO COMPLY WITH | | | NFPA 241. | | | | | | 2) NO WORK IS TO INTERFERE WITH ANY | | | EXIT ACCESS, EXITING, OR EXIT DISCHARGE. | | | | | | 3) ALL COMBUSTIBLE WASTE IS TO BE | | | REMOVED FROM THE BUILDING DAILY. | | | | | | 4) NON FIRE RATED VISQUEEN OR OTHER | | | NON APPROVED MATERIALS SHALL NOT BE HUNG | | | FROM THE CEILING. | | | | | | 5) ALL REQUIRED FIRE SPRINKLER AND | | | FIRE ALARM SYSTEMS ARE TO REMAIN IN | | | OPERATION. | | | | | | 6) NO CUTTING OR WELDING OPERATIONS | | | ALLOWED TO BE DONE WITHOUT APPROVAL | | | OF THE BUREAU OF FIRE PREVENTION. | | | | | | 7) ALL NEW STAIRS AND RAMPS ARE REQUIRED | | | TO HAVE HANDRAILS ON BOTH SIDES. | | | | | | 8) ALL NEW COOLERS AND FREEZERS SHALL | | | BE FIRE SPRINKLER PROTECTED. | | | | | | 9) NO TRIPPING HZARDS SHALL EXIST | | | DURING FLOOR WORK. | | | | | | 10) PROPER VENTILATION IS TO BE | | | PROVIDED DURING OPERATION OF GASOLINE | | | POWERED EQUIPMENT TO AVOID CARBON | | | MONOXIDE. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-08-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-29 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-29 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2003-08-29 00:00:00 | ON COMM BD #56 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-19 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-29 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2003-05-19 00:00:00 | COMM BOARD #45 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-05-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-05-23 |
Time |
12:50 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2003-05-23 |
Time |
12:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-09-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-09-30 |
Time |
16:21 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-09-30 |
Time |
16:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-06-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-12 |
Time |
11:31 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2003-06-11 |
Time |
18:49 |
Sent To |
|
|
| Notes |
| 2003-06-12 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A-1 PLEASE SHOW CLEAR FLOOR SPACE | | | FOR WOMEN'S HDCP STALL, (#105), AND MENS | | | HDCP STALL, (#120) PER SECTION 11-4.22.3 | | | 2) SHT PB-1 PLUMBING NOTES #5, AIR CHAM- | | | BERS ARE NOT APPROVED. PLEASE DELETE RE- | | | FERENCE. | | | 3) SEPARATE GAS PERMIT REQUIRED. | | | 4) SHT PD-1 ANY PLUMBING PIPING DEMO'ED | | | SHALL BE INSPECTED PRIOR TO COVERING. | | | 5) SHT P-1 SINK P-7 IN LOUNGE, (#115), | | | SHALL COMPLY WITH SECTION 11-4.24 & ALL | | | SUBSECTIONS. PLEASE PROVIDE A DETAIL. | | | 6) SHT P-1 KEYNOTES #11, NEW FILTERS | | | SHALL BE NSF APPROVED. PLEASE SUBMIT | | | MANUF. INFORMATION. | | | 7) SHT P-2 WATER RISER ISOMETRIC, ALL | | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | | NEAR THE FIXTURES, IN AN "EFFICTIVE | | | RANGE", NOT IN THE CEILING AT THE TOP OF | | | THE DROPS. PDI-WH 201 & MANUF. INSTALL- | | | ATION INSTRUCTIONS. | | | 8) SHT P-5 DETAIL 8/P-5, CONDENSATE TRAP | | | DETAIL. FLOOR DRAIN NOT AN APPROVED IN- | | | DIRECT WASTE RECEPTOR. FLOOR SINK OR HUB | | | DRAIN REQUIRED. SECTIONS 802.3 & 802.3.2 | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
|