| Plan Review Stops For Permit 03051279 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-08-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-08-09 |
Time |
09:08 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
2003-08-07 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2003-08-07 00:00:00 | ***************PROVISO***************** | | | | | | 1. SEPARATE PERMITS REQUIRED FOR MECH, | | | PLUMB & ROOF.NOT SIGNED ON PERMIT AT | | | TIME OF APPLICATION. | | | | | | 2. DESIGN PRESSURES TO BE SUBMITTED FOR | | | ALL OPENINGS. | | | | | | 3. UPLIFT ADJUSTMENTS TO BE SUBMITTED BY | | | FLORIDA REGISTERED ENGINEER. | | | | | | 4. ALL WINDOWS & GLASS DOORS ARE IMPACT | | | NO HURRICANE PANELS REQUIRED. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-07-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-06 |
Time |
11:12 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-07-14 00:00:00 | ****************FAILED*************** | | | | | | THE FOLLOWING ITEMS ARE STILL NOT | | | COMPLETED FOR BUILDING APPROVAL: | | | 1. PRODUCT APPROVALS EXTERIOR DOORS | | | 2. PRODUCT APPROVALS WINDOWS. | | | (NOTE ONLY FIXED GLASS WINDOWS | | | SUBMITTED.) | | | 3.STORM PANELS WITH SCHEDULE FOR | | | INSTALLATION. | | | 4. A NOTICE OF COMMENCEMENT MUST BE | | | FILED BEFORE A PERMIT CAN BE ISSUED. | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-06-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-11 |
Time |
18:24 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2003-05-30 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2003-05-30 00:00:00 | ****************FAILED************* | | | | | | 1. THE FOLLOWING PRODUCT APPROVALS MUST | | | BE SUBMITTED: DADE COUNTY OR SBCCI: | | | 1. ROOF MATERIALS | | | 2. WINDOWS & DOORS | | | | | | 2.PROVIDE ENERGY CALCULATIONS | | | AS REQUIRED BY THE 2001 FLORIDA | | | ENERGY EFFICIENCY CODE FOR BUILDING | | | CONSTRUCTION. | | | SEE FBC CHAPTER 13-101.2.2. | | | | | | 3. ALL WINDOWS/DOORS MUST MEET THE FBC | | | FOR IMPACT.IF HURRICANE PANELS ARE | | | REQUIRED PRODUCT APPROVALS MUST BE | | | SUBMITTED SHOWING TYPEOF PANELS AND | | | INSTALLATION SCHEDULE WITH TYPE OF | | | ANCHORS. | | | | | | 4. PER SHEET A-8 NOTES: UPLIFTS | | | ADJUSTMENTS TO BE SUBMITTED SIGNED & | | | SEALED BY FLORIDA REGISTERED ENGINEER. | | | | | | 5. SEPARATE PERMITS REQUIRED FOR | | | PLUMBING & MECHANICAL & ROOFING. | | | | | | 6. A NOTICE OF COMMENCEMENT MUST BE FILE | | | BEFORE A PERMIT CAN BE ISSUED. | | | | | | 7. BEFORE A PERMIT TO CONSTRUCT MAY | | | BE ISSUED IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2004-06-21 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2004-06-21 |
Time |
08:53 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2004-06-21 |
Time |
08:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2004-05-05 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-06-16 |
Time |
15:22 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-05-05 |
Time |
06:51 |
Sent To |
|
|
| Notes |
| 2004-05-05 00:00:00 | *********** UNSAT ***************** | | | | | | 1)NOTE: PLEASE SEE FAC 61G1-16.004, | | | FS 481.219. PLEASE PROVIDE ALL LICENSE | | | #'S ON TITLE BLOCK AS REQ'D PER ABOVE. | | | PLEASE SEE TITLE BLOCK IS MISSING | | | CA# AS REQ'D UNDER FS. | | | | | | 2)NOTE: PLEASE PROVIDE LAYOUT OF EXIST- | | | -ING DWELLING'S ELECTRICAL DEVICES. | | | ALL ELECTRICAL IN EXSITING DWELLING | | | MUST MEET CODE FOR DEVICES/WIRING TO | | | 2002 NEC PER FBC CHAPTER 34. 3401.7.1 | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2004-04-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-29 |
Time |
16:50 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2004-04-09 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2004-04-09 00:00:00 | | | | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | NOTE: PLEASE NOTE, ALL PLANS DRAWN | | | BY AN ARCHITECT/ENGINEER CONTAIN- | | | ING A TITLE BLOCK: MUST BE SIGNED, | | | DATED AND SEALED BY THAT ARCH/ENG. | | | PER FS 481.221 471.025 | | | FAC 61G15-23.002, 61G1-16.004 | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-07-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-05 |
Time |
14:05 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-07-25 |
Time |
15:11 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-07-10 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-24 |
Time |
15:50 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-07-10 |
Time |
10:30 |
Sent To |
P |
|
| Notes |
| 2003-07-10 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | NOTE: PLEASE NOTE THAT ALL PLANS | | | DRAWN BY AN ARCHITECT/ENGINEER CONTAIN- | | | ING A TITLE BLOCK, MUST BE SIGNED, | | | DATED AND SEALED BY THE ARCH/ENGINEER OF | | | RECORD. PER FS/FAC 481.221 & 471.025 | | | | | | THE RISER DIAGRAM LISTS THE "NEW PANEL" | | | AS 125 A MLO,THE PANEL SCHEDULE LIST | | | SAME AS 100 AMP MAIN BREAKER,PLEASE | | | CLARIFY. | | | | | | THE PANEL SHOWS THE W.HEATER AT 20 AMPS | | | AND THE DRYER @ 20 AMPS,BUT THE LOAD | | | CALCULATIONS LIST THEM AS 4500 WATTS | | | AND 5000 WATTS RESPECTIVELY,PLEASE | | | CORRELATE | | | | | | PLEASE LIST THE REQ`D BATH(S) | | | CIRCUIT(S). PER 210-11-C-3 | | | MUST BE 20A AND #12AWG,AND SHALL HAVE NO | | | OTHER OUTLETS. | | | | | | PLEASE MAKE THE CORRECTIONS AND RESUBMIT | | | FOR REVIEW.IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-05-22 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-02 |
Time |
11:29 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-05-22 |
Time |
12:20 |
Sent To |
P |
|
| Notes |
| 2003-05-22 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE PROVIDE THE FOLLOWING AND | | | RESUBMIT FOR REVIEW. | | | | | | 1} PLEASE PROVIDE LOAD CALCULATIONS AND | | | RISER DIAGRAM OF THE EXISTING LOADS AND | | | ALL ADDED LOADS,PER 215-5 NEC.INDICATE | | | HOW SUB PANEL IS BEING FED. | | | | | | 2} PLEASE LIST THE REQ'D BATH(S) | | | CIRCUIT(S). PER 210-11-C-3 | | | MUST BE 20A AND #12AWG. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-06-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-06-16 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-06-16 |
Time |
15:21 |
Sent To |
E |
|
| Notes |
| 2004-06-16 00:00:00 | SENT TO BT DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-04-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-29 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-29 |
Time |
16:50 |
Sent To |
E |
|
| Notes |
| 2004-04-29 00:00:00 | TO DP DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-04-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-05 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-05 |
Time |
14:05 |
Sent To |
E |
|
| Notes |
| 2004-04-05 00:00:00 | TO BT DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-07-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-24 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-24 |
Time |
15:50 |
Sent To |
E |
|
| Notes |
| 2003-07-24 00:00:00 | TO BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-07-02 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-02 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-02 |
Time |
11:29 |
Sent To |
E |
|
| Notes |
| 2003-07-02 00:00:00 | BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-05-21 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-21 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-21 |
Time |
16:41 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-05-16 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-16 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-16 |
Time |
11:57 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-08-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-08-09 |
Time |
09:08 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2003-08-09 |
Time |
09:08 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-05-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-24 |
Time |
10:57 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-05-27 |
Time |
09:57 |
Sent To |
B |
|
| Notes |
| 2003-05-27 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR REVIEW | | | PLEASE PROVIDE ENERGY & MANUAL J CALCS | | | WITH MECHANICAL PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-08-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-06 |
Time |
11:04 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-08-06 |
Time |
11:04 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-07-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-07-25 |
Time |
15:52 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-07-11 |
Time |
18:14 |
Sent To |
B |
|
| Notes |
| 2003-07-11 00:00:00 | DENIED | | | REFERENCE: FLORIDA STATUTES | | | | | | 1) SHT A-9 ALL PLANS DRAWN BY AN ARCHIT- | | | ECT SHALL BE SIGNED, SEALED AND DATED. | | | NO SEAL ON SHEET #9. 61G1-16.003 | | | 2) FROM PREVIOUS REVIEW COMMENT NOT | | | ADDRESSED. | | | D) FLA STATUTES 61G1-16.004 MINIMUM | | | INFORMATION REQUIRED, FIRM LICENSE NUM- | | | BER REQUIRED ON EACH SHEET. | | | 3) WHEN RESUBMITTING PLANS, REMOVE AND | | | REPLACE ANY PAGES AS NECESSARY. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-05-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-07-10 |
Time |
11:09 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-05-24 |
Time |
10:29 |
Sent To |
M |
|
| Notes |
| 2003-05-24 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SANITARY RISER DIAGRAM DOES NOT MEET | | | CODE REQUIREMENTS. | | | A) SECTION 909.1 ONLY FIXTURES OF THE | | | BATHROOM GROUP SHALL DRAIN INTO THE WET | | | VENT FOR THE BATHROOM. - TIE LAUNDRY | | | SINK DOWNSTREAM OF BATHROOM FIXTURES. | | | B) MINIMUM SIZE PIPE FOR WASHMACHINE IS | | | 2". TABLE 709.1 - CLEANOUT REQUIRED MIN. | | | 4' ABOVE FINISHED FLOOR AT W/MACHINE. | | | C) MINIMUM SIZE TRAP FOR LAUNDRY SINK IS | | | 1-1/2" PER TABLE 709.1. | | | ---SEE RED LINE CORRECTIONS ON PLANS AND | | | MAKE CORRECTONS TO PLANS AND RESUBMIT. | | | D) FLA. STATUTES 61G1-16.004 MINIMUM | | | INFORMATION REQUIRED, FIRM LICENSE NUM- | | | BER REQUIRED ON EACH SHEET. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-05-21 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-16 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-05-21 00:00:00 | DENIED, NEED SURVEY |
|
|