| Plan Review Stops For Permit 03051031 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2003-09-02 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-09-02 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-09-02 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2003-09-02 00:00:00 | REVISION SUBMITTED 8-27-03 FOR INTERIOR | | | WALL AND DOOR RELOCATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-07-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-27 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-07-22 |
Time |
10:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-06-25 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-06-25 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-06-25 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2003-06-25 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 6/5/03: | | | | | | 3) 11-4.15WATER COOLER. NOTE 17 STATES | | | THAT THE TENANT IS TO PROVIDE A WATER | | | COOLER.THE PLANS SHALL BE AMENDED/ | | | ANNOTATED TO SPECIFY THE REQUIREMENTS | | | FOR SPOUT HEIGHT/LOCATION AND FOR | | | WHEELCHAIR APPROACH CLEARANCES (REF: | | | FIG. 27).ANY PLUMBING PLAN REVIEW | | | COMMENTS ON THE WATER COOLER OR DRINKING | | | FOUNTAIN REQUIREMENTS SHALL BE ADDRESSED | | | | | | 4) FBC 11-4.13.6MANEUVERING CLEARANCES | | | AT DOORS. DOOR 3 SHALL HAVE AT LEAST 18" | | | CLEARANCE BETWEEN THE LEADING EDGE OF | | | THE DOOR AND THE ADJACENT OFFICE WALL ON | | | THE PULL SIDE OF THE DOOR (REF: FIG. 25) | | | | | | 5) THE PLAN HAS BEEN REDRAWN.THE NEW | | | SHEETS SHALL BE REVIEWED AND STAMPED | | | 'APPROVED' BY THE CITY PLACE | | | ADMINISTRATION. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-06-05 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-06-05 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-06-05 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2003-06-05 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) FBC* 104.2.2THE SUBMITTED 'GENERAL | | | NOTES' SHEET SHALL BE SIGNED, DATED AND | | | SEALED BY THE DESIGN PROFESSIONAL OF | | | RECORD. | | | | | | 2) FBC 11-4.1.6(3)(E) ACCESSIBLE TOILET. | | | THE PLAN DOES NOT STATE WHETHER THE | | | EXISTING TOILET IS ACCESSIBLE, ADAPTABLE | | | (PER FAIR HOUSING ACCESSIBILITY GUIDE, | | | AS THIS IS A 'LIVE/WORK LOFT') OR | | | NON-ACCESSIBLE.AMEND THE PLAN TO | | | DEMONSTRATE COMPLIANCE WITH THE | | | REQUIREMENT FOR AN ACCESSIBLE TOILET. | | | | | | 3) FBC 11-4.1.3DRINKING FOUNTAIN. | | | AMEND THE PLANS TO SHOW THE PROVISION OF | | | AN ACCESSIBLE DRINKING FOUNTAIN WITH | | | HEIGHT AND CLEARANCES IN COMPLIANCE WITH | | | FIG 27. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2003-08-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-08-18 |
Time |
11:27 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-08-18 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2003-08-18 00:00:00 | REDLINED REQ'D SIGN CIRCUIT 600.5 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2003-07-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-07-22 |
Time |
15:29 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-07-22 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2003-07-22 00:00:00 | ************* UNSAT **************** | | | | | | 1)NOTE: PLEASE SEE NOTES FROM OTHER | | | ELECTRICAL REVIEWS. | | | PLANS ARE NOT SUFF. FOR COMPLETE REVIEW. | | | CIRCUITING/PANEL SCHEDULES ETC . | | | | | | PLEASE CALL IF THERE ARE ANY QUESTIONS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2003-06-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-06-25 |
Time |
06:11 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-06-25 |
Time |
06:11 |
Sent To |
|
|
| Notes |
| 2003-06-25 00:00:00 | *********** UNSAT ************* | | | | | | PLANS FOR MIN ELEC AND LIFE SAFTEY REQ`D | | | | | | | | | | | | 1)NOTE: PLEASE SEE NOTES FROM FIRST | | | REVIEW. | | | | | | 2)NOTE: PLEASE SEE FIRE REVIEW COMMENTS | | | FOR EXIT/ EM LTS, THAT WILL HAVE AN | | | AFFECT ON ELECTRICAL | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF ELECTRICAL WILL BE SEPARATE, | | | PLEASE HAVE ELECTRICAL SUBMITTED IN | | | ORDER TO REVIEW MIN LIFE SAFETY REQ'MENT | | | -S FOR FIRE AND ELECTRICAL. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-05-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-05-27 |
Time |
09:24 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2003-05-27 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2003-05-27 00:00:00 | PROVISO | | | ~~~~~~~ | | | ELECTRICAL DRAWING TO BE SUBMITTED | | | SEPERATLY WITH PERMIT APP BY ELECTRICAL | | | CONTRACTOR. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 651/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-05-19 |
Time |
09:12 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-05-19 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2003-05-19 00:00:00 | ************ UNSAT **************** | | | | | | 1)NOTE: PLANS NEED TO SHOW ALL CIRCUIT- | | | -ING AND CORRELATE W/ A SUBMITTED PANEL | | | SCHEDULE. 215-5. | | | | | | 2)NOTE: PLEASE SHOW CIRCUITING FOR EM/ | | | EXT LTS PER 700-12E | | | | | | 3)NOTE: PLEASE CLARIFY TWO OTHER NEW | | | OFFICE AREAS SHOWN W/ NO ELECTRICAL? | | | | | | 4)NOTE" PLEASE SHOW LOAD CALCUALTIONS, | | | PER 220-3,220-10,220-11,220-13 AND ALL | | | CONTINUOUS LOADS AT 125% 230-42/215-3 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2003-08-19 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-08-19 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-08-19 |
Time |
16:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2003-07-25 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-07-25 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-07-25 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2003-07-25 00:00:00 | 1) PLEASE LOCATE ALL EXIT SIGNS AND | | | EMERGENCY LIGHT FIXTURES. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2003-06-26 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-06-26 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-06-26 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2003-06-26 00:00:00 | 1) OCCUPANCY CLASSIFICATION CHANGE TO | | | BUSINESS OFFICE THE MEANS OF EGRESS HAS | | | TO BE MARKED IE EXIT LIGHT AND EMERGENCY | | | LIGHTS. | | | | | | 2) NO SIGNED CITY PLACE STAMP ON NEW | | | PLANS SUBMITTED. | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-06-04 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-06-04 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-06-04 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2003-06-04 00:00:00 | 1) IS THIS BUILDING FIRE SPRINKLERED IF | | | SO HOW DOES THESE WALLS AFFECT THE FIRE | | | SPRINKLER COVERAGE. | | | | | | 2) ARE THESE WALLS FLOOR TO CEILING. | | | | | | 3) SEPARATE PLAN AND PERMIT APPLICATION | | | WILL BE REQUIRED FOR FIRE SPRINKLER | | | REMODEL. | | | | | | 4) WHAT IS THE FINISH CLASSFICATION FOR | | | THE WALLS. | | | | | | 5) WILL THERE BE A NEED FOR FIRE ALARM | | | REMODEL, IF SO SEPARATE PLAN AND PERMIT | | | APPLICATION IS REQUIRED. | | | | | | NATE MCCRAY, CAPTAIN | | | 659-8096, EXT 8497 | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-08-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-27 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-27 |
Time |
14:10 |
Sent To |
B |
|
| Notes |
| 2003-08-27 00:00:00 | TO RB DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-08-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-13 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-13 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2003-08-13 00:00:00 | TO COMM BD. #24 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-08-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-13 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-13 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2003-08-13 00:00:00 | TO COMM BD. #24 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-07-21 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-21 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-21 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2003-07-21 00:00:00 | COMM BOARD #6 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-23 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-23 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2003-06-23 00:00:00 | COMM BOARD #11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-05-15 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-15 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-15 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2003-05-15 00:00:00 | COMM BOARD #57 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2003-07-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-07-26 |
Time |
11:43 |
Rev Time |
0.05 |
| Received By |
pkrauss |
Date |
2003-07-26 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2003-07-26 00:00:00 | NO MECHANICAL PLANS SUBMITTED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-05-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-05-23 |
Time |
12:54 |
Rev Time |
0.15 |
| Received By |
pkrauss |
Date |
2003-05-23 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2003-05-23 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR REVIEW |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2003-08-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-18 |
Time |
18:50 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-08-18 |
Time |
18:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-07-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-29 |
Time |
14:51 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2003-07-29 |
Time |
14:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-07-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-05 |
Time |
12:56 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-07-05 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2003-07-05 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | A) FROM PREVIOUS REVIEW | | | 1) IF THE OCCUPANCY CLASSIFICATION OR | | | OCCUPANCY SUBCLASSIFICATION OF ANY | | | BUILDING OR STRUCTURE IS CHANGED, THE | | | BUILDING, ELECTRICAL, GAS, MECHANICAL, & | | | PLUMBING SYSTEMS SHALL BE MADE TO CON- | | | FORM TO THE INTENT OF THE TECHNICAL | | | CODES AS REQUIRED BY THE BUILDING OFFI- | | | CAL. SEC 3401.2.2.1 BLDG CODE | | | 20 11-4.1.1(6) IF BATHING FACILITIES ARE | | | PROVIDED ON A SITE, THEN EACH SUCH PUB- | | | LIC OR COMMON USE BATHING FACILITY SHALL | | | COMPLY WITH SECTION 11-4.23 - BATHING | | | ROOM DETAIL REQUIRED. SHOW CLEAR FLOOR | | | SPACE, TURNING CIRCLE, HEIGHTS, GRAB- | | | BARS, ECT. SHOW COMPLIANCE FOR ALL SECT- | | | IONS AND SUBSECTIONS REQUIRED BY CODE. | | | *** NEW COMMENTS *** | | | 3) IF A WATER COOLER IS USED, IS SHALL | | | COMPLY WITH ARI-1010 AS PER SEC 410.4 & | | | MANUF INFO. IS REQUIRED AT TIME OF FINAL | | | PLUMBING INSPECTION. | | | 4) TURNING CIRCLE NOT SHOWN IN TOILET | | | ROOM. PLEASE SHOW ON TOILET ROOM DETAIL. | | | SECTION 11-4.22.3 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-06-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-11 |
Time |
12:21 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2003-06-11 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2003-06-11 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | FBC-2001 BUILDING | | | | | | 1) IF THE OCCUPANCY CLASSIFICATION OR | | | OCCUPANCY SUBCLASSIFICATION OF ANY | | | BUILDING OR STRUCTURE IS CHANGED, THE | | | BUILDING, ELECTRICAL, GAS, MECHANICAL, & | | | PLUMBING SYSTEMS SHALL BE MADE TO CON- | | | FORM TO THE INTENT OF THE TECHNICAL | | | CODES AS REQUIRED BY THE BUILDING OFFI- | | | CAL.SEC 3401.2.2.1 | | | 2) 11-4.1.1(6) IF TOILET FACILITIES ARE | | | PROVIDED ON A SITE, THEN EACH SUCH PUB- | | | LIC OR COMMON USE TOILET FICILITY SHALL | | | COMPLY WITH 11-4.22. IF BATHING FACILIT- | | | IES ARE PROVIDED ON A SITE, THEN EACH | | | SUCH PUBLIC OR COMMON USE BATHING FACIL- | | | ITY SHALL COMPLY WITH SECTION 11-4.23. | | | SUBMIT DETAIL FOR BOTH THE TOILET ROOM | | | AND THE BATHROOM. SHOW CLEAR FLOOR SPACE | | | AND TURNING CIRCLE, HEIGHTS, GRAB BARS, | | | ECT. SHOW DETAILS FOR ALL SUBSECTIONS. | | | 3) KITCHEN SINK SHALL CONFORM TO SECTION | | | 11-4.24 AND ALL SUBSECTIONS. SUBMIT DE- | | | TAIL FOR SINK SHOWING COMPLIANCE WITH | | | ALL SUBSECTIONS. | | | 4) TABLE 403.1 REQUIRES A DRINKING | | | FOUNTAIN. (ALSO SEE SECTION 410.1) | | | 5) IF ANY CHANGES TO THE SANITARY PIPING | | | OR WATER PIPING SYSTEMS, A SANITARY | | | RISER DIAGRAM AND A WATER DIAGRAM SHALL | | | BE REQUIRED. SEC 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|