| Plan Review Stops For Permit 03050843 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-07-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2003-07-03 |
Time |
13:21 |
Rev Time |
1.50 |
| Received By |
jgomez |
Date |
2003-07-03 |
Time |
13:21 |
Sent To |
PC |
|
| Notes |
| 2003-07-03 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-PROVIDE COMPLETE FRAMING DETAIL FOR | | | WINDOW SHOWING HOW FRAME IS REINFORCED | | | TO RECEIVE THE STORM SHUTTERS. SECTION | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | 2-PROVIDE COMPLETE WALL SECTION FOR | | | GABLE END WALL. SPECIFY ALL FASTENERS. | | | SEE SEC. 2313.4 FBC 2001. | | | 3-PRODUCT APPROVALS FOR DOORS & WINDOWS | | | SUBMITTED DON'T HAVE LEGIBLE DRAWINGS. | | | PLEASE, RESUBMIT PRODUCT APPROVALS | | | WITH LEGIBLE DRAWINGS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-01 |
Time |
15:27 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2003-06-23 |
Time |
15:43 |
Sent To |
PC |
|
| Notes |
| 2003-06-23 00:00:00 | SECOND CHECKLIST: | | | 1-PRODUCT INFORMATION SUBMITTED FOR THE | | | FIXED WINDOW IS NOT ACCEPTABLE. THIS | | | INFORMATION IS ONLY FOR A COMPONENT OF | | | THE ASSEMBLY AND IS NOT FOR STRUCTURAL | | | ASSEMBLY. NEED DADE COUNTY OR SBCCI | | | CURRENT PRODUCT APPROVAL OR COMPLETE | | | SITE SPECIFIC ENGINEERING FOR ASSEMBLY | | | & INSTALLATION OF THIS WINDOW. PROVIDE | | | COMPLETE PRODUCT APPROVAL FORM FOR | | | SITE SPECIFIC WINDOWS (ATTACHED)SIGNED | | | & SEALED BY MANUFACTURER'S ENGINEER | | | AND BY THE ARCHITECT OF RECORD. | | | 2-PROVIDE COMPLETE FRAMING DETAIL FOR | | | FIXED WINDOW REINFORCEMENT TO RECEIVE | | | THE STORM SHUTTERS. AND SHOW HOW ARE | | | SHUTTERS TO BE INSTALLED. HORIZONTALLY | | | OR VERTICALLY. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | 3-RESUBMIT PRODUCT APPROVAL WITH LEGIBLE | | | DRAWINGS FOR: | | | A)DOUBLE HUNG WINDOW. | | | B)EXTERIOR FRENCH DOORS. | | | | | | 4-OWES $55.00 FOR UPDATED VALUATION AND | | | RADON FEES. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-05-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-06-19 |
Time |
14:50 |
Rev Time |
1.50 |
| Received By |
jgomez |
Date |
2003-05-30 |
Time |
10:05 |
Sent To |
E |
|
| Notes |
| 2003-05-30 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1-ARCHITECT TO PROVIDE PLANS WITH THE | | | EMBOSSED SEAL AS REQUIRED BY CHAPTER | | | 481 FLORIDA STATUTES WHEN SUBMITTING | | | PLANS FOR PUBLIC RECORDS. | | | 2-REAR PORCH ADDITION: A)ARCHITECT TO | | | CLARIFY CONNECTION OF WOOD POST TO | | | BEAM. THE ONLY CONNECTION SHOWN IS THE | | | 12"X 5/8" LAG SCREW. WHAT IS THE | | | CALCULATED UPLIFT LOAD TO BE RESISTED | | | AT THIS CONNECTION?. SEC. 104.2.1.2 | | | CITY AMENDMENTS TO FBC 2001. | | | B)NEED COMPLETE SPECS FOR CONSTRUCTION | | | OF GABLE END WALL. SPECIFY ALL FASTE- | | | NERS. SEC. 104.2.1.2 CITY AMENDMENTS. | | | | | | 3-BATHROOM ADDITION: A)PROVIDE COMPLETE | | | DETAILS & SPECIFICATIONS FOR CONSTRUC- | | | TION OF GABLE END WALL CONSIDERING THE | | | WINDOW. CLARIFY HOW IS THIS WALL | | | DESIGNED TO COMPLY WITH SEC. 2313.4 | | | FBC 2001. | | | B)PROVIDE COMPLETE FRAMING DETAILS FOR | | | DOORS AND WINDOWS SHOWING REINFORCE- | | | MENT TO RECEIVE STORM SHUTTERS. SEC. | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | C)SPECIFY ATTACHMENT OF NEW EXTERIOR | | | WALLS TO EXISTING WALLS. SEC. 104.2.1. | | | 2 CITY AMENDMENTS TO FBC 2001. | | | | | | 4-PROVIDE PRODUCT APPROVAL FOR: | | | A)ROOF SHINGLES. | | | B)WALL WOOD SHINGLES. | | | C)DOUBLE HUNG WINDOW (NOT CASEMENT). | | | D)EXTERIOR FRENCH DOOR. | | | E)FIXED WINDOW AS SHOWN ON PLANS. | | | F)STORM SHUTTERS. | | | | | | 5-OWES $55.00 FOR UPDATED VALUATION AND | | | RADON FEES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-06-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-06-19 |
Time |
14:50 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-06-19 |
Time |
14:41 |
Sent To |
B |
|
| Notes |
| 2003-06-19 00:00:00 | TO JULIO./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-05-30 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-19 |
Time |
10:51 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2003-05-30 |
Time |
10:50 |
Sent To |
B |
|
| Notes |
| 2003-05-30 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | THE NOTES FOR THE ELECTRICAL WORK WILL | | | NOT SUFFICE.PLEASE SHOW COMPLIANCE WITH | | | 210-52(D) FOR SPACING REQUIREMENTS AND | | | 210-11-(C)(3) FOR CIRCUIT REQUIREMENTS. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-07-01 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-01 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-01 |
Time |
15:27 |
Sent To |
B |
|
| Notes |
| 2003-07-01 00:00:00 | JGOMEZ DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-06-19 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-19 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-19 |
Time |
10:51 |
Sent To |
E |
|
| Notes |
| 2003-06-19 00:00:00 | BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-05-20 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-20 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-20 |
Time |
09:58 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-05-15 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-05-19 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-15 |
Time |
09:47 |
Sent To |
Z |
|
| Notes |
| 2003-05-15 00:00:00 | RESUB W/ SURVEY. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-05-09 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-09 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-09 |
Time |
08:58 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-05-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-22 |
Time |
09:29 |
Rev Time |
0.10 |
| Received By |
pkrauss |
Date |
2003-05-23 |
Time |
09:21 |
Sent To |
B |
|
| Notes |
| 2003-05-23 00:00:00 | NO MECHANICAL PLANS SUBMITTED/REQUIRED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2003-05-22 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-20 |
Time |
10:00 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-05-22 |
Time |
09:28 |
Sent To |
M |
|
| Notes |
| 2003-05-22 00:00:00 | NO PLUMBING PLANS SUBMITTED |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-05-19 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-05-12 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-15 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-05-12 00:00:00 | DENIED, NEED A SURVEY SHOWING THE | | | ADDITIONS WITH THE SETBACKS |
|
|