Plan Review Details - Permit 03050679
Plan Review Stops For Permit 03050679
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-07-09 Cont ID  
Sent By jgomez Date 2003-07-09 Time 18:19 Rev Time 0.50
Received By jgomez Date 2003-07-09 Time 18:19 Sent To PC
Notes
2003-07-09 00:00:00CHECKLIST:
 1-PROVIDE SURVEY WITH CORRECT LOT #.
 SURVEY SUBMITTED SHOWS LOT 67 TWICE.
 REVISED AS REQUIRED.
 2-STORM SHUTTERS: REVISE SPACING FOR
 WOOD ANCHORS. SEE THE ENGINEERED
 DRAWINGS AND REVISE THE INSTALLATION
 SCHEDULE AS REQUIRED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-06-16 Cont ID  
Sent By shernand Date 2003-06-23 Time 14:28 Rev Time 2.00
Received By jgomez Date 2003-06-16 Time 16:37 Sent To PC
Notes
2003-06-16 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-REVISE SURVEY. LOT 67 IS WRITTEN TWICE
 ONE OF THEM NEED TO BE LOT 68.
 2-WINDOW 34SH IN BEDROOMS DOESN'T ALLOW
 THE 24" OPENING REQUIRED BY SECTION
 1005.4.4 FBC 2001. REVISE AS REQUIRED.
 3-REVISE TRUSS ANCHOR SCHEDULE AND ALL
 DETAILS THAT ARE AFFECTED BY SECTION
 1609.4.3 FBC 2001, WHICH DOESN'T
 ALLOW THE STEEL STRESS INCREASE.
 4-STORM PANELS INSTALLATION SCHEDULE:
 **ANCHORS TO BE SPACED 12" O.C. (NOT
 12.5") IF EDGE DISTANCE IS 2". REVISE
 AS REQUIRED.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-10-15 Cont ID  
Sent By dpalmer Date 2003-10-15 Time 16:05 Rev Time 0.33
Received By dpalmer Date 2003-10-15 Time 16:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-05-19 Cont ID  
Sent By csiegber Date 2003-10-10 Time 12:03 Rev Time 0.25
Received By dpalmer Date 2003-05-19 Time 11:43 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-11-03 Cont ID  
Sent By csiegber Date 2003-11-03 Time 14:39 Rev Time 0.00
Received By csiegber Date 2003-11-03 Time 14:39 Sent To M
Notes
2003-11-03 00:00:00TO PK BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-10-10 Cont ID  
Sent By csiegber Date 2003-10-10 Time 12:03 Rev Time 0.00
Received By csiegber Date 2003-10-10 Time 12:03 Sent To E
Notes
2003-10-10 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-23 Cont ID  
Sent By shernand Date 2003-06-23 Time 14:28 Rev Time 0.00
Received By shernand Date 2003-06-23 Time 14:28 Sent To B
Notes
2003-06-23 00:00:00JGOMEZ DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-08 Cont ID  
Sent By shernand Date 2003-05-08 Time 14:39 Rev Time 0.00
Received By shernand Date 2003-05-08 Time 14:39 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-11-13 Cont ID  
Sent By pkrauss Date 2003-11-13 Time 14:00 Rev Time 0.25
Received By pkrauss Date 2003-11-13 Time 14:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-06-04 Cont ID  
Sent By csiegber Date 2003-11-03 Time 14:39 Rev Time 0.25
Received By pkrauss Date 2003-06-04 Time 08:01 Sent To B
Notes
2003-06-04 00:00:00MECHANICAL PERMIT 03050713

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-05-17 Cont ID  
Sent By kstevens Date 2003-05-17 Time 15:49 Rev Time 0.25
Received By kstevens Date 2003-05-17 Time 15:49 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-15 Cont ID  
Sent By shernand Date 2003-05-08 Time 14:39 Rev Time 1.00
Received By mmclean Date   Time   Sent To E
Notes
***NONE***