Plan Review Details - Permit 03050619
Plan Review Stops For Permit 03050619
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-09-15 Cont ID  
Sent By sthyng Date 2003-09-15 Time 19:12 Rev Time 1.00
Received By sthyng Date 2003-09-15 Time 19:12 Sent To  
Notes
2003-09-15 00:00:00PROVISO (SEE PREVIOUS CORRECTION LIST)

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-08-19 Cont ID  
Sent By kstevens Date 2003-09-10 Time 11:41 Rev Time 1.55
Received By jwitmer Date 2003-08-19 Time 15:21 Sent To  
Notes
2003-08-19 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03050619
 ADD: 703 14TH STREET
 CONT: BUENA VISTA BUILDERS
 TEL: (561)358-8371
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 2ND REVIEW
  
 ACTION: DENIED
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 PROVISO:
 1) FL BLD CODE 2405.2 HAZARDOUS LOCATION
 PROVIDE SAFETY GLASS FOR THIS LOCATION:
 BATH# 2, GLASS WITHIN 3'-0" OF THE TUB.
  
 2) TRUSSANCHOR SCHEDULE, PA-28 2765LBS
 SIMPSON NOTE# 7, MUST BE USED IN A CON-
 CRETE TIE BEAM.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-06-19 Cont ID  
Sent By dpalmer Date 2003-08-12 Time 12:39 Rev Time 1.50
Received By jwitmer Date 2003-06-19 Time 07:04 Sent To  
Notes
2003-06-19 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03050619
 ADD: 703 14TH ST
 CONT: BUENA VISTA BUILDERS
 TEL: (561)358-8371
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ACTION: DENIED
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED. MISSING REPORTS:
 A) ROOFING (EXPIRED)
 B) STORM SHUTTERS (ADDITIONAL INFO)
  
 3)FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE. MISSING KEY PLAN IDENTIFYING
 SHUTTER LAYOUT.
  
 4) 1707.4.4.2 TAPERED BUCKS:
 SHALL EXTEND BEYOND THE INTERIOR FACE
 OF THE WINDOW OR DOOR FRAME SUCH THAT
 FULL SUPPORT OF THE FRAME IS SUPPORTED.
  
 5) FL BLD CODE 2405.2 HAZARDOUS LOCATION
 PROVIDE SAFETY GLASS FOR THIS LOCATION:
 BATH# 2, WITHIN 3'-0" OF TUB.
  
 6) INTERNAL PRESSURE COEFFICIENT IS
 APPLIABLE, FOR A SINGLE STORY, ENCLOSED
 STRUCTURE IS: +-.18
 FOR PARTIALLY ENCLOSED +-.55
 FOR OPEN STRUCTURE, 0.0
 IF YOU ARE SAYING THERE IS NO PRESSURE
 THEN IT IS TO DESIGNED AS A OPEN BUILD-
 ING?
  
 7)1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS SPE
 CIFIED IN THE MATERIALS SECTIONS OF THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23.
  
 RE-EVALUATE TRUSS ANCHOR SCHEDULE!!!
 USP USE 2003 CATALOG REDUCED VALUES(FL)
 SIMPSON USE 2003 HIGH WIND CATALOG(FL)
  
 8) FL BLD CODE 2309.6 ATTIC ACCESS, PRO-
 VIDE ATTIC ACCESS 20"X36".
  
 9)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)659-8096 X 8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-08-12 Cont ID  
Sent By dpalmer Date 2003-08-12 Time 11:33 Rev Time 0.75
Received By dpalmer Date 2003-08-12 Time 11:33 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-05-19 Cont ID  
Sent By alange Date 2003-08-07 Time 14:13 Rev Time 0.33
Received By dpalmer Date 2003-05-19 Time 13:10 Sent To P
Notes
2003-05-19 00:00:00************** UNSAT ****************
  
 1)NOTE: PLEASE INDICATE IF PANEL "A"
 IS MCB. 225-31, 240-3
  
 2)NOTE: PLEASE SUBIT AIC RATING(S) FOR
 MAIN/ PANEL. 110-9/215-5
  
 3)NOTE: PLEASE LIST THE REQ`D ARC FAULT
 PROTECTED CIRCUITS ON PANEL SCHEDULE.
 210-12
  
 4)NOTE: PLEASE LIST THE REQ`D BATH
 CIRCUIT(S) ON PANEL SCHEDULE. 210-52D,
 210-11C3
  
 5)NOTE: PLEASE SEE MISSING SD`S IN ALL
 SLEEPING ROOMS AND OUTSIDE ALSO. REQ`D
 BY NFPA-72 8-1.4.2
  
 6)NOTE: PLEASE SEE MISSING GFI RECEPT
 PER 210-52E
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-09-04 Cont ID  
Sent By csiegber Date 2003-09-04 Time 11:07 Rev Time 0.00
Received By csiegber Date 2003-09-04 Time 11:07 Sent To P
Notes
2003-09-04 00:00:00TO KS TRAY

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-07 Cont ID  
Sent By alange Date 2003-08-07 Time 14:12 Rev Time 0.00
Received By alange Date 2003-08-07 Time 14:12 Sent To E
Notes
2003-08-07 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-07 Cont ID  
Sent By shernand Date 2003-05-07 Time 13:46 Rev Time 0.00
Received By shernand Date 2003-05-07 Time 13:46 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-06-04 Cont ID  
Sent By kstevens Date 2003-05-23 Time 18:25 Rev Time 0.20
Received By pkrauss Date 2003-06-04 Time 11:51 Sent To B
Notes
2003-06-04 00:00:00MECHANICAL PERMIT 03050626

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-09-10 Cont ID  
Sent By kstevens Date 2003-09-10 Time 11:41 Rev Time 0.50
Received By kstevens Date 2003-09-10 Time 11:41 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-08-15 Cont ID  
Sent By csiegber Date 2003-09-04 Time 11:07 Rev Time 0.33
Received By kstevens Date 2003-08-15 Time 09:19 Sent To  
Notes
2003-08-15 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) ONLY THE FIXTURES WITHIN THE BATH-
 ROOM GROUPS SHALL CONNECT TO THE WET-
 VENTED HORIZONTAL BRANCH DRAIN. ANY
 ADDITIONAL FIXTURES SHALL DISCHARGE
 DOWNSTREAM OF THE WET VENT. SEC 909.1
 WASH MACHINE SHALL TIE IN DOWNSTREAM OF
 BATHROOM GROUP.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-05-23 Cont ID  
Sent By dpalmer Date 2003-08-12 Time 12:40 Rev Time 0.25
Received By kstevens Date 2003-05-23 Time 18:25 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-15 Cont ID  
Sent By shernand Date 2003-05-07 Time 13:46 Rev Time 1.00
Received By mmclean Date   Time   Sent To E
Notes
***NONE***