Plan Review Details - Permit 03050617
Plan Review Stops For Permit 03050617
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-09-16 Cont ID  
Sent By sthyng Date 2003-09-16 Time 16:48 Rev Time 0.00
Received By sthyng Date 2003-09-16 Time 16:48 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-09-15 Cont ID  
Sent By csiegber Date 2003-09-16 Time 16:08 Rev Time 0.50
Received By sthyng Date 2003-09-15 Time 20:03 Sent To  
Notes
2003-09-15 00:00:00IMPACT & NOC

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-08-19 Cont ID  
Sent By csiegber Date 2003-09-09 Time 11:32 Rev Time 1.25
Received By jwitmer Date 2003-08-19 Time 12:42 Sent To  
Notes
2003-08-19 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03050617
 ADD: 414 8TH ST
 CONT: BUENA VISTA
 TEL: (561)358-8371
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 2ND REVIEW
  
 ACTION: DENIED
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3) TRUSS ANCHOR SCHEDULE INDICATES
 UPDATES AFTER PLANS REVISED, (PRESSURES
 HAND WRITTEN IN ) THE ENGINEER OF RECORD
 HAS NOT SEALED A COVER LETTER INDICATING
 THE CHANGE.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-06-23 Cont ID  
Sent By jleech Date 2003-08-11 Time 18:20 Rev Time 1.55
Received By jwitmer Date 2003-06-23 Time 14:10 Sent To  
Notes
2003-06-23 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03050617
 ADD: 414 8TH ST
 CONT: BUENA VISTA
 TEL: (561)358-8371
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ACTION: DENIED
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED. MISSING REPORTS:
 A) ROOFING (EXPIRED)
 B) STORM SHUTTERS (ADDITIONAL INFO)
  
 3) SHEET 3 WALL SECTION, ROOF SHINGLE
 NOTE, 225 LBS/ SQ. UPDATE TO CURRENT
 LOADING PER SQUARE.
  
 4)FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE. SEE SAMPLE.
  
 5) 1707.4.4.2 TAPERED BUCKS:
 SHALL EXTEND BEYOND THE INTERIOR FACE
 OF THE WINDOW OR DOOR FRAME SUCH THAT
 FULL SUPPORT OF THE FRAME IS SUPPORTED.
  
 6) FL BLD CODE 2405.2 HAZARDOUS LOCATION
 PROVIDE SAFETY GLASS FOR THIS LOCATION:
 2 BATHROOMS GLASS WITHIN 3'-0" OF THE
 TUB.
  
 7) INTERNAL PRESSURE COEFFICIENT IS
 APPLICABLE ASCE 7-98 TABLE 6-7 :
 OPEN BUILDINGS +-0.0
 PARTIALLY ENCLOSED+-0.55
 ENCLOSED BUILDING +-0.18
  
 8)1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS SPE
 CIFIED IN THE MATERIALS SECTIONS OF THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23.
  
 RE-EVALUATE TRUSS ANCHOR SCHEDULE!!!
  
 9) FL BLD CODE 2309.6 ATTIC ACCESS, PRO-
 VIDE ATTIC ACCESS 20"X36".
  
 10)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-08-11 Cont ID  
Sent By btrobaug Date 2003-08-11 Time 16:53 Rev Time 0.50
Received By btrobaug Date 2003-08-11 Time 16:30 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-06-03 Cont ID  
Sent By alange Date 2003-08-07 Time 15:14 Rev Time 0.75
Received By btrobaug Date 2003-06-03 Time 14:10 Sent To P
Notes
2003-06-03 00:00:00UNSAT
 ~~~~~
 PLEASE MAKE THE FOLLOWING CHANGES TO THE
 PLAN FOR CODE COMPLIANCE.
  
 1} PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 2} PLEASE LIST THE REQ'D BATH(S)
 CIRCUIT(S). PER 210-11-C-3
 MUST BE 20A AND #12AWG.
  
 3} PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CIRCUITS ON PANEL
 SCHEDULE OR NOTE ON PLANS FOR BRANCH
 CIRCUIT PROTECTION. PER 210-12
  
 4} SHOW SMOKE DETECTORS PER 8-1.4.2
 NFPA-72.
  
 5} PLEASE NOTE THAT FUTURE FAN OUTLETS
 SHOWN ARE NOT IN COMPLIANCE WITH THE
 INTENT OF 210-70(A)(1).
  
 IF THERE ARE ANY QUESTIONS PLESE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-09-16 Cont ID  
Sent By csiegber Date 2003-09-16 Time 16:08 Rev Time 0.00
Received By csiegber Date 2003-09-16 Time 16:08 Sent To B
Notes
2003-09-16 00:00:00TO ST DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-09-09 Cont ID  
Sent By csiegber Date 2003-09-09 Time 11:31 Rev Time 0.00
Received By csiegber Date 2003-09-09 Time 11:31 Sent To B
Notes
2003-09-09 00:00:00TO JW DESK
 TO JW DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-07 Cont ID  
Sent By mmclean Date 2003-09-09 Time 10:16 Rev Time 0.00
Received By alange Date 2003-08-07 Time 15:14 Sent To E
Notes
2003-08-07 00:00:00TO BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-03 Cont ID  
Sent By shernand Date 2003-06-03 Time 13:31 Rev Time 0.00
Received By shernand Date 2003-06-03 Time 13:31 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-07 Cont ID  
Sent By shernand Date 2003-05-07 Time 13:46 Rev Time 0.00
Received By shernand Date 2003-05-07 Time 13:46 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-06-16 Cont ID  
Sent By pkrauss Date 2003-06-16 Time 07:45 Rev Time 0.25
Received By pkrauss Date 2003-06-16 Time 07:44 Sent To P
Notes
2003-06-16 00:00:00MECHANICAL PERMIT 03050632

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-08-11 Cont ID  
Sent By jleech Date 2003-08-11 Time 18:20 Rev Time 0.33
Received By jleech Date 2003-08-11 Time 18:20 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-06-17 Cont ID  
Sent By btrobaug Date 2003-08-11 Time 16:53 Rev Time 0.50
Received By jleech Date 2003-06-17 Time 16:44 Sent To  
Notes
2003-06-17 00:00:00DENIED;
 PLUMBING RISER DOES NOT MATCH FLOOR
 PLAN. WASHING MACHINE MISSING FROM RISER
 DIAGRAM. TIE TUB DRAIN INTO TOILET DRAIN
 DELETE DRY VENT.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT 8369

Review Stop Z ZONING
Rev No 3 Status P Date 2003-09-08 Cont ID  
Sent By mmclean Date 2003-09-09 Time 10:16 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
2003-09-09 00:00:009/9/03 PAS PER DANA LITTLES EXT 8511
 WITH AN ATTACHED SKETCH ON PLANS MM

Review Stop Z ZONING
Rev No 2 Status F Date 2003-06-11 Cont ID  
Sent By sgraham Date 2003-06-11 Time 08:33 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
2003-06-11 00:00:00THE CONTRACTOR HAS BEEN CONTACTED,
 WAITING FOR MEETING WITH ARCHITECT

Review Stop Z ZONING
Rev No 1 Status F Date 2003-06-03 Cont ID  
Sent By shernand Date 2003-05-07 Time 13:46 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
2003-06-03 00:00:00DENIED, URBAN DESIGN HAS SET MEETING
 WITH APPLICANT


Account Summary | Usage Policy | Privacy Policy