Plan Review Details - Permit 03050555
Plan Review Stops For Permit 03050555
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-07-01 Cont ID  
Sent By lmartine Date 2003-07-01 Time 12:40 Rev Time 2.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-06-09 Cont ID  
Sent By dpalmer Date 2003-06-24 Time 13:12 Rev Time 4.00
Received By lmartine Date   Time   Sent To  
Notes
2003-06-09 00:00:00 
 BUILDING COMMENTS
 -------- --------
  
 1]
 SUBMIT TWO SIGNED AND SEALED SURVEYS.
  
 2]
 PROVIDE PRODUCT TEST REPORTS FOR
 EXTERIOR WINDOWS,DOORS AND ROOF COVER.
  
 3]
 PROVIDE DETAIL FOR DRAFTSTOPPING PER
 2305.2 FBC AT FLOOR/CEILING ASSEMBLY.
  
 4]
 SEE 1007.5 FBC, VERIFY HANDRAILS ARE
 BETWEEN 34" AND 38", AND THAT HANDRAILS
 SHALL BE INSTALLED ON BOTH SIDES OF THE
 STAIR.
  
 5]
 SUBMIT WIND DESIGN CRITERIA.
  
 6]
 CALCULATE ATTIC VENTING AS PER 2309.7
 FBC.
  
 7]
 SUBMIT ENERGY EFFICIENCY REPORT.
  
  
  
  
 L. MATINEZ
 805-6710

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-03-23 Cont ID  
Sent By btrobaug Date 2004-03-23 Time 17:24 Rev Time 0.50
Received By btrobaug Date 2004-03-23 Time 17:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-06-24 Cont ID  
Sent By dpalmer Date 2003-06-24 Time 13:12 Rev Time 1.00
Received By dpalmer Date 2003-06-24 Time 13:11 Sent To B
Notes
2003-06-24 00:00:00NOTES REDLINED FOR RECEPTS PER 210-52

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-05-19 Cont ID  
Sent By kstevens Date 2003-05-17 Time 15:07 Rev Time 0.75
Received By dpalmer Date 2003-05-19 Time 11:01 Sent To M
Notes
2003-05-19 00:00:00************* UNSAT ********************
  
 1)NOTE: PLEASE SUBMIT A COMPLETE RISER
 DIAGRAM, LOAD CALCS, PANEL SCHEDULE(S)
 ETC FOR SERVICE OF HOUSE. 215-5
  
 2)NOTE: PLEASE SHOW ALL OUTLETS SERVING
 KITCHEN COUNTERSPACE AS GFI/ GFI
 PROTECTED. 210-8A6
  
 3)NOTE: PLEASE SEE MISSING SD ON FIRST
 LEVEL AT BOTTOM OF STAIRS. (VICINITY)
 NFPA-72 8-1.4.2
  
 PLEASE NOTE, DUE TO PLANS NOT BEING
 COMPLETE AT THIS TIME, THERE MAY BE
 OTHER COMMENTS TO FOLLOW.
 PLEASE REMOVE ALL OLD/VOIDED SHEETS AND
 INSERT NEW SHEETS INTO TWO COMPLETE SETS
 FOR REVIEW AND STAMPING.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 4)NOTE: PLEASE SEE MISING RECEPT PER
 210-52E FRONT AND REAR.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-11-20 Cont ID  
Sent By csiegber Date 2003-11-20 Time 17:20 Rev Time 0.00
Received By csiegber Date 2003-11-20 Time 17:20 Sent To P
Notes
2003-11-20 00:00:00TO GAS

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-06-23 Cont ID  
Sent By shernand Date 2003-06-23 Time 15:01 Rev Time 0.00
Received By shernand Date 2003-06-23 Time 15:00 Sent To M
Notes
2003-06-23 00:00:00PK DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-18 Cont ID  
Sent By mmclean Date 2003-06-19 Time 15:08 Rev Time 0.00
Received By shernand Date 2003-06-18 Time 10:39 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-06 Cont ID  
Sent By shernand Date 2003-05-06 Time 09:30 Rev Time 0.00
Received By shernand Date 2003-05-06 Time 09:30 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-06-23 Cont ID  
Sent By pkrauss Date 2003-06-23 Time 16:09 Rev Time 0.50
Received By pkrauss Date 2003-06-23 Time 15:32 Sent To P
Notes
2003-06-23 00:00:00PROVISO:MECHANICAL PERMIT 03061028
  
 PLEASE PROVIDE COMBUSTION AIR CALCS
 FOR THE FIREPLACE PRIOR TO ROUGH
 INSPECTION.
  
 PROVIDE SCHEDULE FOR THE EXHAUST FANS.
 PROVIDE MANUFACTURER SUBMITTAL DATA ON
 THE JOBSITE AT TIME OF INSPECTION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-05-29 Cont ID  
Sent By shernand Date 2003-06-23 Time 15:01 Rev Time 0.25
Received By hmoser Date 2003-05-29 Time 16:31 Sent To B
Notes
2003-05-29 00:00:00PLAN DENIED
 NO ENERGY CALCULATIONS OR MANUAL (J)
 PLAN REVIEW BY HAROLD MOSER
 PHONE # (561)805-6732

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-06-23 Cont ID  
Sent By csiegber Date 2003-11-20 Time 17:20 Rev Time 0.33
Received By kstevens Date 2003-06-23 Time 17:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-05-17 Cont ID  
Sent By pkrauss Date 2003-06-23 Time 16:50 Rev Time 0.50
Received By kstevens Date 2003-05-17 Time 15:06 Sent To E
Notes
2003-05-17 00:00:00 
  
 PASSED/PROVISO
  
 SECTION 905.3 NO HORIZONTAL DRY VENTS
 SECTION 706.3 NO BACK TO BACK FITTINGS
 WHEN PUMP DISCHARGE APPLIANCES

Review Stop Z ZONING
Rev No 2 Status P Date 2003-06-19 Cont ID  
Sent By mmclean Date 2003-06-19 Time 15:08 Rev Time 1.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2003-05-07 Cont ID  
Sent By shernand Date 2003-06-18 Time 10:40 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
2003-05-07 00:00:00 
 DENIED
 1. NEED SURVEY OF PROPERTY
 2. 1000 SQUARE FT OF LANDSCAPING
 REQUIRED IN FRONT SETBACK
 3. SEPARATE PERMIT REQUIRED FOR FENCE