| Plan Review Stops For Permit 03050555 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-07-01 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2003-07-01 |
Time |
12:40 |
Rev Time |
2.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-06-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-06-24 |
Time |
13:12 |
Rev Time |
4.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-06-09 00:00:00 | | | | BUILDING COMMENTS | | | -------- -------- | | | | | | 1] | | | SUBMIT TWO SIGNED AND SEALED SURVEYS. | | | | | | 2] | | | PROVIDE PRODUCT TEST REPORTS FOR | | | EXTERIOR WINDOWS,DOORS AND ROOF COVER. | | | | | | 3] | | | PROVIDE DETAIL FOR DRAFTSTOPPING PER | | | 2305.2 FBC AT FLOOR/CEILING ASSEMBLY. | | | | | | 4] | | | SEE 1007.5 FBC, VERIFY HANDRAILS ARE | | | BETWEEN 34" AND 38", AND THAT HANDRAILS | | | SHALL BE INSTALLED ON BOTH SIDES OF THE | | | STAIR. | | | | | | 5] | | | SUBMIT WIND DESIGN CRITERIA. | | | | | | 6] | | | CALCULATE ATTIC VENTING AS PER 2309.7 | | | FBC. | | | | | | 7] | | | SUBMIT ENERGY EFFICIENCY REPORT. | | | | | | | | | | | | | | | L. MATINEZ | | | 805-6710 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-03-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-23 |
Time |
17:24 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-03-23 |
Time |
17:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-06-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-06-24 |
Time |
13:12 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-06-24 |
Time |
13:11 |
Sent To |
B |
|
| Notes |
| 2003-06-24 00:00:00 | NOTES REDLINED FOR RECEPTS PER 210-52 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-17 |
Time |
15:07 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-05-19 |
Time |
11:01 |
Sent To |
M |
|
| Notes |
| 2003-05-19 00:00:00 | ************* UNSAT ******************** | | | | | | 1)NOTE: PLEASE SUBMIT A COMPLETE RISER | | | DIAGRAM, LOAD CALCS, PANEL SCHEDULE(S) | | | ETC FOR SERVICE OF HOUSE. 215-5 | | | | | | 2)NOTE: PLEASE SHOW ALL OUTLETS SERVING | | | KITCHEN COUNTERSPACE AS GFI/ GFI | | | PROTECTED. 210-8A6 | | | | | | 3)NOTE: PLEASE SEE MISSING SD ON FIRST | | | LEVEL AT BOTTOM OF STAIRS. (VICINITY) | | | NFPA-72 8-1.4.2 | | | | | | PLEASE NOTE, DUE TO PLANS NOT BEING | | | COMPLETE AT THIS TIME, THERE MAY BE | | | OTHER COMMENTS TO FOLLOW. | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | INSERT NEW SHEETS INTO TWO COMPLETE SETS | | | FOR REVIEW AND STAMPING. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | 4)NOTE: PLEASE SEE MISING RECEPT PER | | | 210-52E FRONT AND REAR. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-11-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-20 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-20 |
Time |
17:20 |
Sent To |
P |
|
| Notes |
| 2003-11-20 00:00:00 | TO GAS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-23 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-23 |
Time |
15:00 |
Sent To |
M |
|
| Notes |
| 2003-06-23 00:00:00 | PK DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-06-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-06-19 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-18 |
Time |
10:39 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-05-06 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-06 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-06 |
Time |
09:30 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-06-23 |
Time |
16:09 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2003-06-23 |
Time |
15:32 |
Sent To |
P |
|
| Notes |
| 2003-06-23 00:00:00 | PROVISO:MECHANICAL PERMIT 03061028 | | | | | | PLEASE PROVIDE COMBUSTION AIR CALCS | | | FOR THE FIREPLACE PRIOR TO ROUGH | | | INSPECTION. | | | | | | PROVIDE SCHEDULE FOR THE EXHAUST FANS. | | | PROVIDE MANUFACTURER SUBMITTAL DATA ON | | | THE JOBSITE AT TIME OF INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-05-29 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-23 |
Time |
15:01 |
Rev Time |
0.25 |
| Received By |
hmoser |
Date |
2003-05-29 |
Time |
16:31 |
Sent To |
B |
|
| Notes |
| 2003-05-29 00:00:00 | PLAN DENIED | | | NO ENERGY CALCULATIONS OR MANUAL (J) | | | PLAN REVIEW BY HAROLD MOSER | | | PHONE # (561)805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-20 |
Time |
17:20 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-06-23 |
Time |
17:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-05-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-06-23 |
Time |
16:50 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-05-17 |
Time |
15:06 |
Sent To |
E |
|
| Notes |
| 2003-05-17 00:00:00 | | | | | | | PASSED/PROVISO | | | | | | SECTION 905.3 NO HORIZONTAL DRY VENTS | | | SECTION 706.3 NO BACK TO BACK FITTINGS | | | WHEN PUMP DISCHARGE APPLIANCES |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-06-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-06-19 |
Time |
15:08 |
Rev Time |
1.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-05-07 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-18 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-05-07 00:00:00 | | | | DENIED | | | 1. NEED SURVEY OF PROPERTY | | | 2. 1000 SQUARE FT OF LANDSCAPING | | | REQUIRED IN FRONT SETBACK | | | 3. SEPARATE PERMIT REQUIRED FOR FENCE |
|
|