Plan Review Details - Permit 03050539
Plan Review Stops For Permit 03050539
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-06-18 Cont ID  
Sent By pkrauss Date 2003-06-18 Time 14:10 Rev Time 3.50
Received By jgomez Date 2003-06-18 Time 13:09 Sent To PC
Notes
2003-06-18 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-REVISE ENERGY CALCULATIONS:
 A)HOW IS R-12.9 INSULATION ACHIEVED ON
 THE EXTERIOR MASONRY WALL. SEE PLANS
 BY ARCHITECT.
 B)PROVIDE ORIGINAL SIGNATURES ON BOTTOM
 OF FORM. SEC. 103.0 CHAPTER 13, FBC/01
 2-PROVIDE SOIL TEST REPORT FOR LOT 21.
 ONE SUBMITTED IS FOR LOT 4.
 3-PROVIDE SPECS FOR WWM SUPPORTS IN CONC
 SLAB. SEE SEC. 1909.3 FBC 2001.
 4-SPECIFY GLASS BLOCK SAFETY GLASS BY
 SHOWER AREA IF FACE THICKNESS IS LESS
 THAN 0.25". SEE SEC. 2405.2 FBC 2001.
 5-RESUBMIT STORM PANELS INFORMATION:
 A)DRAWINGS ARE NOT THE SAME AS APPROVED
 ON THE SBCCI REPORT.
 B)ENGINEER IS NOT THE SAME AS THE ONE
 LISTED ON THE SBCCI REPORT.
 C)INCORRECT MEAN ROOF HEIGHT.
 D)CHECK THE DESIGN PRESSURES CALCULATED
 BY THE ENGINEER OF RECORD AND REVISE
 AS REQUIRED.
 E)REVISE ANCHOR SPACING ON INSTALLATION
 SCHEDULE ACCORDING TO EDGE DISTANCE,
 PANEL SPAN, DESIGN PRESSURES, TYPE OF
 CONNECTION & STRUCTURE TO BE ATTACHED
 TO.SEE ENGINEERED DRAWINGS.
 F)REVISE MAXIMUM AND MINIMUN PANEL SPAN.
 SEE ENGINEERED DRAWINGS.
 G)CLEARLY MARK ON ENGINEERED DRAWINGS
 ANCHOR TYPE AND SPACING TO BE USED.
  
 6-PROVIDE 2X STRUCTURAL BUCK DETAIL FOR
 ENTRY DOORS AS REUIRED ON PRODUCT
 APPROVAL.
 7-UPDATE TRUSS ANCHOR SCHEDULE AND ALL
 DETAILS THAT ARE AFFECTED BY SECTION
 1609.4.3 FBC 2001, WHICH DOESN'T ALLOW
 THE STRESS INCREASE TO BE USED.
 8-PROVIDE PRODUCT APPROVAL FOR:
 A)GLASS BLOCK (INFORMATION SUBMITTED IS
 PART OF MANUFACTURER'S SPECS, NOT THE
 ACTUAL PRODUCT APPROVAL).
 B)ENTRY DOORS CURRENT PRODUCT APPROVAL
 WITH DADE COUNTY LOGO AT LEFT BOTTOM
 OF FRONT PAGE AND WITH DRAWINGS WITH
 THE UPDATED STAMP AND NUMBER ON IT.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-05-19 Cont ID  
Sent By kstevens Date 2003-05-17 Time 15:25 Rev Time 0.25
Received By dpalmer Date 2003-05-19 Time 11:28 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-06 Cont ID  
Sent By shernand Date 2003-05-06 Time 11:08 Rev Time 0.00
Received By shernand Date 2003-05-06 Time 11:08 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-06-18 Cont ID  
Sent By dpalmer Date 2003-05-19 Time 11:28 Rev Time 0.25
Received By pkrauss Date 2003-06-03 Time 13:21 Sent To B
Notes
2003-06-03 00:00:00PROVISO:MECHANICAL PERMIT 03050564
  
 SHOW COMPLIANCE FOR COMBUSTION AIR AS
 PER 2001 FBC(M) CHAPTER 7.
 1.DETERMINE CONFINED OR UNCONFINED
 SPACE.
  
 2.CONFINED SPACE SHALL COMPLY WITH
 SECTION 703 OF THE 2001 FBC(M).PROVIDE
 CALCULATIONS AT ROUGH INSPECTION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-05-17 Cont ID  
Sent By kstevens Date 2003-05-17 Time 15:25 Rev Time 0.33
Received By kstevens Date 2003-05-17 Time 15:25 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-14 Cont ID  
Sent By shernand Date 2003-05-06 Time 11:08 Rev Time 1.00
Received By mmclean Date   Time   Sent To E
Notes
***NONE***