Plan Review Details - Permit 03050126
Plan Review Stops For Permit 03050126
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-07-02 Cont ID  
Sent By sthyng Date 2003-07-02 Time 16:21 Rev Time 1.00
Received By sthyng Date 2003-07-02 Time 16:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-06-27 Cont ID  
Sent By shernand Date 2003-07-01 Time 09:50 Rev Time 2.00
Received By jwitmer Date 2003-06-27 Time 15:49 Sent To  
Notes
2003-06-27 00:00:00ACTION: DENIED
 BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-06-13 Cont ID  
Sent By hmoser Date 2003-06-25 Time 17:22 Rev Time 2.25
Received By jwitmer Date 2003-06-13 Time 08:31 Sent To  
Notes
2003-06-13 00:00:00BUILDING PLAN REVIEW
 PERMIT:03050126
 ADD: 139 SANTA LUCIA DRIVE
 CONT: RENDE CONSTRUCTION
 TEL: (561)731-4418
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ACTION: DENIED
 NOTE:
 PROVIDE FLOOD ZONE ELEVATION
 CERTIFICATE FOR NEW CONSTRUTION WITH
 BASE FLOOD ELEVATION, CITY CODE REQUIRES
 AN ADDITIONAL 6".MINIMUM FINISH FLOOR
 ELEVATION 7'-6". THIS SAME MINIMUM IS
 REQUIRED FOR POOL PUMP PAD & A/C CONDEN-
 SER PAD!!! FLOOD ELEVATION CERTIFICATE
 BEFORE TO THIS OFFICE BEFORE CERTIFICATE
 OF OCCUPANCY.
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 3)ALL INFORMATION, DRAWINGS, SPECIF-
 ICATIONS AND ACCOMPANYING DATA SHALL
 BEAR THE NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE DESIGN.
 CITY AMENDMENTS 104.2.1
  
 4)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 5)2001 FL BLD CODE, 1005.4:
 PROVIDE EMERGENCY EGRESS WINDOWS IN
 SLEEPING ROOMS WITH A MINIMUM NET CLEAR
 OPENING HEIGTH OF 24" AND NET CLEAR
 OPENING WIDTH OF 20" AND A NET CLEAR
 OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR
 OPENINGS ARE PERMITTED TO HAVE A NET
 CLEAR OPENING OF 5.0 SQ. FT. SILL HEIGTH
 SHALL NOT BE MORE THAN 44 " ABOVE THE
 FINISH FLOOR.
 PRODUCT APPROVAL INDICATES CASEMENT
 WINDOWS FOR EGRESS WINDOWS, PGT MAKES A
 25 WINDOW IN A SINGLE LEAF AND AS A 2
 LEAF WINDOW, THE WINDOW SCHEDULE DOESN'T
 DESCRIBETHIS CONDITION, THE ELEVATIONS
 INDICATE (FRONT) THE USE OF 2 LEAF WIN-
 DOWS MAKING THEM INACCESSIBLE FOR EGRESS
 WINDOWS.
 THE SIDE VIEW INDICATES EITHER SINGLE
 HUNG WINDOWS OR HORIZONTAL SLIDERS VS
 THE WINDOW SCHEDULE CASEMENT?
  
 6) 1007.8.1 WINDERS SHALL HAVE A
 MINIMUM TREAD DEPTH OF 6" AT THE NARROW-
 EST EDGE & SHALL HAVE A MINIMUM TREAD
 DEPTH OF 11" AT A POINT 12" FROM THE
 NARROW EDGE. WINDERS SHALL BE PERMITTED
 TO BE USED AS A COMPONENT IN MEANS OF
 EGRESS WITHIN A DWELLING UNIT.
  
 7)1015.2 HEIGHT. GUARDRAILS SHALL
 FORM A VERTICAL PROTECTIVE BARRIER NOT
 LESS THAN 42" HIGH.
 1015.3 OPENINGS. OPEN GUARDRAILS
 SHALL HAVE INTERMEDIATE RAILS OR ORNA-
 MENTAL PATTERNS SUCH AS A 4" DIAMETER
 SPHERE CAN NOT PASS THROUGH. A BOTTOM
 RAIL OR CURB SHALL BE PROVIDED THAT WILL
 REJECT THE PASSAGE OF 2" DIAMETER
 SPHERE. GUARDRAIL INDICATES 6-8" SPHEERE
 CAN PASS THROUGH.
  
 8)FBC 13-103.1.2 BEFORE A BUILDING
 PERMIT CAN BE ISSUED, THE SUBMITTED
 ENERGY CODE COMPLIANCE FORMS SHALL BE
 SIGNED BY THE BUILDING OWNER, THE
 OWNER'S ARCHETECT OR OTHER AUTHORIZED
 AGENT LEGALLY DESIGNATED BY THE OWNER.
  
 9)FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 DESCRIPENCY: ENERGY SHEET R=19 VS R=30
 IN THE PLANS P-7.
  
 10)1606.1.4(1) IN WIND BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES
 POSITIVE PRESSURE IN BUILDINGS SHALL BE
 ASSUMED TO BE OPENINGS UNLESS SUCH
 GLAZING IS IMPACT RESISTANT OR PROTECTED
 WITH AN IMPACT RESISTANT COVERING MEET-
 ING THE REQUIREMENTS OF SSTD 12, ASTM
 E 1886 AND ASTM E 1996 OR MIAMI-DADE.
 1) GLAZED OPENINGS LOCATED WITHIN 30 FT
 OF GRADE SHALL MEET THE REQUIREMENTS OF
 LARGE MISSLE TEST.
 DOOR (A) SHALL REQUIRE STORM PANELS
 PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
  
 11)1707.4.4.2 TAPERED BUCKS:
 SHALL EXTEND BEYOND THE INTERIOR FACE
 OF THE WINDOW OR DOOR FRAME SUCH THAT
 FULL SUPPORT OF THE FRAME IS SUPPORTED.
  
 12) SHEET S-3 TRUSS ANCHOR SCHEDULE
 1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS SPE
 CIFIED IN THE MATERIALS SECTIONS OF THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23.
  
 13) SHEET # 7 TRUSSES, "FIRE CUT"SEE
 2305.4FLOOR TRUSS DETAIL.
  
 14) 2305.2.2 FLOOR/CEILING ASSEMBLIES
 SINGLE FAMILY DWELLINGS. IN FLOOR/CEIL/
 ING ASSEMBLIES SEPERATING USEABLE SPACE
 INTO 2 OR MORE APPROXIMATE AREAS WITH NO
 AREA GREATER THAN 500 SQ FT. DRAFTSTOP-
 PING SHALL BE PROVIDED PARALLEL TO THE
 MAIN FRAMING MEMBERS.
  
 15)FL BLD CODE 2309.6 ATTIC ACCESS, PRO-
 VIDE ATTIC ACCESS 20"X36". INDICATE
 ATTIC ACCESS 2ND FLOOR.
  
 16)FL BLD CODE 2405.2 HAZARDOUS LOCATION
 PROVIDE SAFETY GLASS FOR THIS LOCATION:
 MASTER BATH WINDOW.
  
 17) SHEET 6 DETAIL OF BALCONY INDICATES
 THE TOP STEEL OF SLAB BUT NOT THE
 BOTTOM STEEL OR SPACING?
  
 18) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 PROVIDE MANUFACTURERS SPEC FOR ELEVATOR.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)659-8096 X 8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-02-23 Cont ID  
Sent By btrobaug Date 2004-02-23 Time 12:32 Rev Time 0.50
Received By btrobaug Date 2004-02-23 Time 12:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-06-23 Cont ID  
Sent By dpalmer Date 2003-06-23 Time 16:29 Rev Time 0.75
Received By dpalmer Date 2003-06-23 Time 16:29 Sent To P
Notes
2003-06-23 00:00:00*********** NOTES REDLINED ***********
  
 1)NOTE: PLEASE SEE CONDUCTOR SIZE AND
 OCP FOR 10KW HEATSTRIP. SHOWS 40A AND #8
 ON PANEL SCHEDULE AND SHOWS 60A #8 ON
 LOAD CALCAULTIONS.
 SIZE PER 424-3 60A #6`S.
  
 2)NOTE: PLEASE SEE OCP SHOWN FOR WASHER
 ON LOAD CALCULATIONS. SHOWS 30A OCP FOR
 #12. (MISPRINT).
  
  
 PLEASE SEE THAT THE ABOVE IS REDLINED
 ON PLANS AND NO CORRECTIONS ARE NEEDED
 AT THIS TIME.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-05-17 Cont ID  
Sent By shernand Date 2003-06-17 Time 16:08 Rev Time 0.50
Received By dpalmer Date 2003-05-17 Time 04:08 Sent To P
Notes
2003-05-17 00:00:00*************** UNSAT *************
  
 1)NOTE: PLEASE SEE FS/ FAC 61G15-23.002
 ALL PLANS SIGNED AND SEALED BY AN ENG
 MUST CONTAIN A TITLE BLOCK CONTAINING
 ALL INFORMATION AS REQ`D IN ABOVE FS.
 NAME, ADDRESS, LICENSE #, ETC
  
 2)NOTE: SERVICE ENTRANCE CONDUCTORSNOT
 RATED FOR 225A. PLEASE SEE 310-15(B)6
 FOR MIN SEC`S.
 PLEASE ALSO SEE FOR NEUTRAL COND. SIZE.
  
 3)NOTE: PLEASE SEE LOAD CALCUALTIONS FOR
 A/C SYSTEMS. PLEASE SEE MULTIPLE LOADS
 SHOWN AND REPEATED. PLEASE SHOW AS SET
 FORTH IN NEC 220.
 PLEASE VERIFY SIZE OF HEAT FOR 6KW UNITS
 IF UNITS ARE 6W? < THEN PLEASE SIZE
 CONDUCTORS AND OCP PER 310-16 AND 424-3B
 MIN 125%.
  
 4)NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) ON PANEL SCHEDULE PER 210-52D
 210-11C3
  
 5)NOTE: PLEASE LIST THE REQ`D ARC FAULT
 CIRCUITS ON PANEL SCHEDULE PER 210-12.
  
 6)NOTE: PLEASE SUBMIT/SHOW AIC RATING
 FOR MAIN. AIC RATINGS ARE SHOWN FOR
 BRANCH BRKRS. 110-9/215-5
  
 7)NOTE: PLEASE SHOW ALL REQ`D GFI/GFI
 PROTECTED RECEPTS. 210-8/ 210-8A6
 KITCHEN, GARAGE/ OUTSIDE, BATH(S) ,
 LAUNDRY RM.
 8)NOTE: PLEASE SEE MISSING SD REQ`D ON
 SECOND FLR NFPA-72 8-1.4.2 ON FIRST FLR
 IN IMMEDIATE VICINITY OF STAIRS LEADING
 TO FLR ABOVE.
  
 9)NOTE:PLEASE CLARIFY RECEPT SHOWN ON
 STAIRS? MISPRINT
  
 10)NOTE: PLEASE SHOW SERVICE/PANEL ON
 PLANS.(LOCATION)
  
 11)NOTE: PLEASE SHOW EITHER, ELEC HOOK-
 -UP OR DISC FOR WATER HEATER, DEPENDING
 ON LOCATION OF PANEL?
  
 12)NOTE: PLEASE SHOW ALL A/C EQUIPMENT
 ON ELEC PLANS. DISC`S, REQ`D RECEPT?
 440-11
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. PLEASE TAKE OUT ALL OLD/VOIDED
 SHEETS AND INSERT NEW SHEETS INTOTWO
 COMPLETE SETS FOR REVIEW AND STAMPING.
  
 PLEASE ALSO SEE G-1/G-2 SIGNATURE FOR
 ENG MUST BE ORIG SIG. PER FS 471.025
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-01 Cont ID  
Sent By shernand Date 2003-07-01 Time 09:50 Rev Time 0.00
Received By shernand Date 2003-07-01 Time 09:50 Sent To B
Notes
2003-07-01 00:00:00JW DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-17 Cont ID  
Sent By shernand Date 2003-06-17 Time 16:08 Rev Time 0.00
Received By shernand Date 2003-06-17 Time 16:08 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-05 Cont ID  
Sent By shernand Date 2003-05-05 Time 12:27 Rev Time 0.00
Received By shernand Date 2003-05-05 Time 12:27 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-06-25 Cont ID  
Sent By hmoser Date 2003-06-25 Time 17:22 Rev Time 0.50
Received By hmoser Date 2003-06-25 Time 17:21 Sent To B
Notes
2003-06-25 00:00:00PASS PRIVISO
 1) REFER TO SECTION 610.ABC.3.5.2
 CHAPTER 13 FLORIDA ENERGY CODE 2001.
 2) REFER TO SECTION 606.2.1 SMOKE
 DETECTION 2001 MECHANICAL CODE.
 3) REFER TO SECTION 402.3.1 BATHROOMS.
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-06-25 Cont ID  
Sent By kstevens Date 2003-06-23 Time 17:34 Rev Time 0.25
Received By hmoser Date 2003-05-28 Time 14:39 Sent To  
Notes
2003-05-28 00:00:00DENIED:MECHANICAL PERMIT 03050196
  
 SEE PLUMBING COMMENTS - TITLE BLOCK
 61G15-23.002(2)
  
 PLAN SHEET #8 MASTER BATH, EXHAUST FAN
 REQUIRED IN SHOWER AREA AS PER 2001 FBC
 (M) 402.3.1 & 502.13.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-06-23 Cont ID  
Sent By kstevens Date 2003-06-23 Time 17:34 Rev Time 0.25
Received By kstevens Date 2003-06-23 Time 17:34 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-05-17 Cont ID  
Sent By dpalmer Date 2003-06-23 Time 16:29 Rev Time 0.33
Received By kstevens Date 2003-05-17 Time 11:23 Sent To M
Notes
2003-05-17 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FLA. STATUTES
  
 1) THE DATE THAT THE SIGNATURE AND SEAL
 IS AFFIXED AS PROVIDED HERIN SHALL BE
 ENTERED ON THE PLANS. 61G15-23.002(1)
 2) ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME, ADDRESS AND NUMBER ON EACH
 SHEET. A TITLE BLOCK WILL SATISFY THIS
 REQUIREMENT. 61G15-23.002(2)
 3) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT THE FLOOR PLAN. BATH #2 SHOWS A
 TUB NOT SHOWN ON FLOOR PLAN.
 4) BAR SINK SHALL NOT THROUGH THE WET
 VENT OF THE BATHROOM FIXTURES. 909.1
 TIE BAR SINK DOWNSTREAM OF BATHROOM FIX-
 TURES. (SEE RED LINE).
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-12 Cont ID  
Sent By shernand Date 2003-05-05 Time 12:27 Rev Time 0.00
Received By sgraham Date   Time   Sent To E
Notes
***NONE***