| Plan Review Stops For Permit 03050050 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2006-06-22 |
Time |
19:32 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2006-06-22 |
Time |
19:32 |
Sent To |
|
|
| Notes |
| 2006-06-22 00:00:00 | STRUCTURAL REVISION SUBMITTED 6/19/06 | | | FOR SHEETS S-7.02 AND S-7.03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2006-06-11 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2006-06-11 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2006-06-11 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2006-06-11 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6652 | | | E-MAIL: [email protected] | | | | | | ARCHITECTURAL/STRUCTURAL REVISION FOR | | | SHEETS A6-2.1, A6-4.2, A6-5.2, A6-6.1, | | | A6-11.1, S-7.02 AND S-7.03 | | | | | | 1) THE ARCHITECTURAL SHEETS HAVE BEEN | | | SEPARATED AND STAMPED SEPARATELY BECAUSE | | | THE SCHEDULE ON STRUCTURAL SHEET S-7.02 | | | HAS AN INCORRECT TRUSS CONNECTOR/HANGER | | | REFERENCE.THE CAPACITIES STATED ON THE | | | PLAN ARE FOR A HHDO212-2 HANGER BUT THE | | | PLAN REFERS TO HDO212-2 WHICH HAS LOWER | | | CAPACITIES.AMEND THE SCHEDULE ON SHEET | | | S-7.02 AND RESUBMIT BOTH STRUCTURAL | | | SHEETS.THE ARCHITECTURAL SHEETS ARE OK | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | TELEPHONE: (561) 805 6652ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-02-19 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2006-02-19 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2006-02-19 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2006-02-19 00:00:00 | ROOF TRUSS DRAWING SUBMITTAL ON 1/20/06. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-02-23 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2005-02-23 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2005-02-23 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2005-02-23 00:00:00 | BUILDING PLAN REVIEW | | | ******PROVISO******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | --PROVISO-- | | | THE WINDOW SCHEDULE DOES NOT STATE THAT | | | THE FIXED GLASS WINDOW MARK G (ADJACENT | | | DOOR 137A) IS TO BE IMPACT RATED.THIS | | | WINDOW SHALL BE IMPACT RATED, OR STORM | | | SHUTTERS (WITH PRODUCT APPROVAL) SHALL | | | BE PROVIDED. | | | | | | --PROVISO-- | | | FOR ACCESSIBILITY, THE WALKWAY LEVEL | | | LEADING TO EACH OF THE BUILDING | | | ENTRANCES/EXITS SHALL BE RAISED TO MATCH | | | THE PATIO SLAB LEVEL.THIS SHALL BE | | | ACHIEVED WITH A WALKWAY SLOPE OF 1 IN 20 | | | OR BETTER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-03-04 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-03-04 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-03-04 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2004-03-04 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | 61G1-16.004FL. ADMIN. CODE.ADD, TO | | | EACH ARCHITECTURAL SHEET, THE PRINTED | | | NAME AND LICENSE NUMBER OF JORGE GARCIA | | | AS THE ARCHITECT WHO SEALED THE PLANS. | | | THIS MAY BE DONE BY STAMP OR HANDWRITTEN | | | | | | THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | --PROVISO-- | | | THE WINDOW SCHEDULE DOES NOT STATE THAT | | | THE FIXED GLASS WINDOW MARK G (ADJACENT | | | DOOR 137A) IS TO BE IMPACT RATED.THIS | | | WINDOW SHALL BE IMPACT RATED, OR STORM | | | SHUTTERS (WITH PRODUCT APPROVAL) SHALL | | | BE PROVIDED. | | | | | | --PROVISO-- | | | FOR ACCESSIBILITY, THE WALKWAY LEVEL | | | LEADING TO EACH OF THE BUILDING | | | ENTRANCES/EXITS SHALL BE RAISED TO MATCH | | | THE PATIO SLAB LEVEL.THIS SHALL BE | | | ACHIEVED WITH A WALKWAY SLOPE OF 1 IN 20 | | | OR BETTER. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-10-17 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-10-17 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-10-17 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2003-10-17 00:00:00 | BUILDING PLAN REVIEW | | | ******PROVISO******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | --PROVISO-- | | | THE WINDOW SCHEDULE DOES NOT STATE THAT | | | THE FIXED GLASS WINDOW MARK G (ADJACENT | | | DOOR 137A) IS TO BE IMPACT RATED.THIS | | | WINDOW SHALL BE IMPACT RATED, OR STORM | | | SHUTTERS (WITH PRODUCT APPROVAL) SHALL | | | BE PROVIDED. | | | | | | --PROVISO-- | | | FOR ACCESSIBILITY, THE WALKWAY LEVEL | | | LEADING TO EACH OF THE BUILDING | | | ENTRANCES/EXITS SHALL BE RAISED TO MATCH | | | THE PATIO SLAB LEVEL.THIS SHALL BE | | | ACHIEVED WITH A WALKWAY SLOPE OF 1 IN 20 | | | OR BETTER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-06-10 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-06-10 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-06-10 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2003-06-10 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | COTTAGE #10 | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEWS (FOR ORIGINAL PERMIT# 02102207) | | | ON 1/3/03 AND 4/24/03: | | | | | | 1) THIS COMMENT HAS NOT BEEN ADDRESSED. | | | FBC* 104.2.4SITE SURVEY.A SIGNED AND | | | SEALED SURVEY DRAWING PREPARED BY A | | | QUALIFIED SURVEYOR IS REQUIRED (REF: | | | 472.025(1) FL. STATUTES). THE SUBMITTED | | | SURVEY SHEET IS FOR A DELRAY BEACH | | | LOCATION (???).SUBMIT TWO COPIES OF AN | | | APPROPRIATE SURVEY DRAWING FOR THIS SITE | | | | | | 3) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 4) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, THE PLANS STAMPED BY THEM | | | AND A COPY OF THE RECEIPT SUBMITTED TO | | | THE CITY OF WEST PALM BEACH CONSTRUCTION | | | SERVICES DEPARTMENT BEFORE A BUILDING | | | PERMIT CAN BE ISSUED. | | | | | | 5) FBC 11-4.1.2EACH OF THE BUILDINGS | | | SHALL BE SERVED BY AT LEAST ONE | | | ACCESSIBLE ROUTE FROM THE ACCESSIBLE | | | PARKING AND THE BUS STOP.ACCEPTABILITY | | | OF THIS APPLICATION IS CONTINGENT UPON | | | THE CIVIL/SITE PLANS, PERMIT# 02102208, | | | BEING PERMITTED. NOTE THAT THE SUBMITTED | | | SITE PLAN (SHEET A6-1.1) DOES NOT SHOW | | | A PATH TO THE ENTRANCE OF COTTAGE #8. | | | | | | 6) FBC 13-103.1.1.1 AND 103.1.2SHEET 2 | | | OF THE SUBMITTED ENERGY CODE COMPLIANCE | | | FORMS SHALL BE SIGNED BY THE OWNER (OR | | | THE PROJECT ARCHITECT, OR OTHER | | | AUTHORIZED AGENT DESIGNATED BY THE | | | OWNER) TO CERTIFY COMPLIANCE WITH THE | | | CODE.ALSO, THE ARCHITECT'S NAME AND | | | REGISTRATION NUMBER SHALL BE ADDED ABOVE | | | THOSE OF THE OTHER SYSTEM DESIGNERS.ON | | | SHEET 1, COMPLETE THE PROJECT DETAILS | | | INCLUDING NAME OF OWNER, PROJECT ADDRESS | | | (4826 N. HAVERHILL RD), ZIP (33417) AND | | | PERMIT NUMBER (03050050). | | | | | | 7) PRODUCT APPROVALS: THE PREVIOUS | | | COMMENTS ON PRODUCT APPROVALS HAVE NOT | | | BEEN ADDRESSED, ALSO THE PRODUCT | | | APPROVAL SHEETS SHALL BE MARKED, AS | | | APPROPRIATE TO IDENTIFY WHICH PRODUCT | | | OPTIONS/MATERIALS ARE TO BE USED: | | | (A) THIS COMMENT HAS NOT BEEN ADDRESSED. | | | ASPHALT SHINGLE PRODUCT APPROVAL | | | NOA# 00-0105.02 EXPIRED ON 4/22/03. | | | SUBMIT A VALID PRODUCT APPROVAL. | | | (B) THE PREVIOUSLY SUBMITTED COPY OF | | | STEELCRAFT MANUF. 98/99 RIM EXIT STEEL | | | DOOR PRODUCT APPROVAL NOA# 01-1203.11 | | | HAS BEEN OMITTED FROM THIS LATEST | | | RE-SUBMITTAL.IS THIS INTENTIONAL? | | | (C) THIS COMMENT HAS NOT BEEN ADDRESSED. | | | THE SUBMITTED COPY OF STEELCRAFT MANUF. | | | F, M FRAME STEEL DOOR PRODUCT APPROVAL | | | NOA# 01-0129.12 IS MISSING TEXT | | | SHEETS 2 AND 3 (SPECIFIC AND GENERAL | | | CONDITIONS), AND SOME OF THE DRAWING | | | SHEETS.SUBMIT A COMPLETE PRODUCT | | | APPROVAL. | | | (D) NOT USED | | | (E) THIS COMMENT HAS NOT BEEN ADDRESSED. | | | THE DRAWING SHEETS OF THE SUBMITTED | | | COPIES OF ARCH ALUMINUM STOREFRONT DOOR | | | PRODUCT APPR. NOA# 01-0919.02 ARE POORLY | | | REPRODUCED.SUBMIT LEGIBLE COPIES. | | | COPIES OF MIAMI-DADE PRODUCT APPROVALS | | | CAN BE PRINTED FROM THEIR WEBSITE,WWW. | | | MIAMIDADE.GOV/BUILDINGCODE/PC-SEARCH.HTM | | | (F) THIS COMMENT HAS NOT BEEN ADDRESSED. | | | THE SUBMITTED 2 PAGE COPY EXTRACT OF THE | | | 48 PAGE GAF MODIFIED BITUMEN ROOF | | | PRODUCT APPROVAL NOA# 00-0331.09 DOES | | | NOT INCLUDE A STATEMENT OF THE MAXIMUM | | | DESIGN PRESSURE AND STATES THAT "ALL | | | GENERAL AND SYSTEM LIMITATIONS SHALL | | | APPLY".SUBMIT COPIES OF THE SHEETS | | | WHICH STATE THE GENERAL AND SYSTEM | | | LIMITATIONS AND THE MAX DESIGN PRESSURE. | | | COPIES OF MIAMI-DADE PRODUCT APPROVALS | | | CAN BE PRINTED FROM THEIR WEBSITE,WWW. | | | MIAMIDADE.GOV/BUILDINGCODE/PC-SEARCH.HTM | | | | | | 16) CONVERSION FROM PLAN CHECK TO PERMIT | | | APPLICATION.SUBMIT TWO COPIES OF THE | | | PLANS FOR EACH COTTAGE BUILDING. | | | | | | 17) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2006-11-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-16 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-16 |
Time |
07:59 |
Sent To |
PC |
|
| Notes |
| 2006-11-16 08:08:28 | REDLINED | | | 2002 NEC. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-20 |
Time |
19:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-20 |
Time |
19:12 |
Sent To |
|
|
| Notes |
| 2006-06-20 00:00:00 | *** REV FOR COTTAGE #10, | | | | | | THIS REVISION WAS FOR POWER PLANS AND | | | PANEL SCHEDULE REV'S ONLY , NO LIGHTING | | | SUBMITTED FOR REVISIONS. | | | ALL CIRCUITING PER 2002 NEC WAS REDLINED | | | ON PLANS. | | | ANY CHANGES SHALL BE SUBMITTED FOR | | | REVIEW BEFORE ROUGH ELECTRICAL | | | INSPECTION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2006-05-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-18 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-18 |
Time |
16:30 |
Sent To |
PC |
|
| Notes |
| 2006-05-18 00:00:00 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE VERIFY CIRCUITING ON | | | PLANS AND CORRELATE WITH THE SUBMITTED | | | PANEL SCHEDULE(S). | | | PLEASE SEE SOME CIRCUITING AS SHOWN ON | | | PLANS FOR RECEPTS DO NOT CORRELATE WITH | | | AFCI BREAKERS IN PANELS. | | | 210.12B | | | | | | 2) NOTE: PLEASE VERIFY SD'S AS | | | CIRCUITING IS NOT SHOWN FOR THESE. IF | | | THESE ARE LV AND FED FROM A FA SYSTEM, | | | PLEASE NOTE ON PLANS. | | | IF NOT PLEASE CIRCUIT AND AFCI. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-04-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-24 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-24 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2006-04-24 00:00:00 | ******* UNSAT ************ | | | | | | 1) NOTE: PLEASE SEE NOTES BELOW AS THE | | | "PROVISO" WHICH WAS SET UP IN ORDER TO | | | ISSUETHE BUILDING PERMIT HAS NOT BEEN | | | ADDRESSED TO DATE. | | | THIS WAS A CONDITION AS PERMITS HAD | | | EXPIRED AND EXTENSION WAS GRANTED BY THE | | | AHJ AND BUILDING OFFICAL THAT ALL | | | ELECTRICAL BE BROUGHT UP TO THE 2002 | | | NEC. THIS WAS REQUIRED TO BE DONE BEFORE | | | ROUGH ELECTRICAL INSPECTION AND TO DATE | | | PLANS MEETING THIS HAVE NOT BEEN | | | SUBMITTED. | | | PLEASE COMPLETE ROOMAND AREA | | | DESIGNATIONS ON PLANS, AND CORRELATE ALL | | | CIRCUTING TO PANEL SCHEDULES TO BE | | | SUBMITTED. | | | PLEASE SEE NOTES. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | DPALMER2WPB.ORG. | | | | | | | | | | | | | | | | | | | | | ******NOTES REDLINED/ PROVISO ********* | | | | | | | | | | | | PURSUANT TO DECISION BY THE AHJ AND | | | BUILDING OFFICAL, CIRCUITING FOR "ALL" | | | BEDROOOM "OUTLETS ARE TO BE BROUGHT UP | | | TO THE 2002 NEC FOR ARC FAULT | | | PROTECTION. PER 210.12 | | | | | | PLANS WILL BE REQUIRED TO BE REVISED IN | | | ORDER TO ADD AF PROTECTION. | | | | | | PLEASE SEE ALL OUTLETS: INCLUSIVE OF | | | SD'S , LTS, RECEPTS, FANS ETC. | | | | | | PLEASE REVISE AND SUBMIT FOR REVIEW | | | BEFORE ROUGH ELECTRICAL INSPECTION. | | | IF THERE ARE ANY QUESTIONS, PLEASE DO | | | NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-02-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-25 |
Time |
14:45 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-02-25 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2005-02-25 00:00:00 | ******NOTES REDLINED/ PROVISO ********* | | | | | | | | | | | | PURSUANT TO DECISION BY THE AHJ AND | | | BUILDING OFFICAL, CIRCUITING FOR "ALL" | | | BEDROOOM "OUTLETS ARE TO BE BROUGHT UP | | | TO THE 2002 NEC FOR ARC FAULT | | | PROTECTION. PER 210.12 | | | | | | PLANS WILL BE REQUIRED TO BE REVISED IN | | | ORDER TO ADD AF PROTECTION. | | | | | | PLEASE SEE ALL OUTLETS: INCLUSIVE OF | | | SD'S , LTS, RECEPTS, FANS ETC. | | | | | | PLEASE REVISE AND SUBMIT FOR REVIEW | | | BEFORE ROUGH ELECTRICAL INSPECTION. | | | IF THERE ARE ANY QUESTIONS, PLEASE DO | | | NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-03-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-03-02 |
Time |
07:06 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-03-02 |
Time |
07:06 |
Sent To |
|
|
| Notes |
| 2004-03-02 00:00:00 | ***UNSAT *** | | | ** COTTAGE #10** | | | | | | 1)NOTE: PLEASE SEE E6-4.01, SHEET HAS | | | CERTICATE OF AUTHORIZATION # ADDED TO | | | TITLE BLOCK AS REQ'D UNDER FS 471.023 | | | NAME AND LICENSE # OF ENGINEER AS REQ'D | | | UNDER FAC 61G15-23.002 HAS ALSO BEEN | | | ADDED TO SAME SHEET. | | | THIS IS REQ'D ON ALL SHEETS AND HAS NOT | | | BEEN A PREVIOUS REVIEW COMMENT. | | | THIS INFORMATION MAY BE ADDED BY HAND. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | THIS INFORMATION IS REQ'D ON ALL SHEETS | | | AND FOR ALL TRADES | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-10-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-03 |
Time |
15:09 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-10-03 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2003-10-03 00:00:00 | ************** UNSAT **************** | | | | | | 1)NOTE: RESPONSE LETTER MENTIONS THE | | | REASON FOR SIZE OF CONDUCTORS ARE DUE TO | | | THE DISTANCE OF 260' AWAY. PLEASE SEE | | | THAT THE MIN SIZE WOULD BE 3/0'S. THE | | | SIZE HAS BEEN INCREASED TO (TWO) SETS | | | OF 250MCM. IT IS UNDERSTANDABLE TO | | | INCREASE TO 250MCM DUE TO VOLTAGE DROP, | | | HOWEVER TWO-SETS OF 250MCM IS NOT CLEAR. | | | PLEASE SEE NOTE FROMLAST REVIEW. | | | IF INDEED 2-SETS OF 250MCM IS INSTALLED, | | | PLEASE PROVIDE A NOTE ON PLAN ON HOW | | | THESE WILL TERMINATE INTO A SINGLE 200A | | | BRKR THAT WILL NOT ACCOMADATE 2-SETS | | | OF 250MCM. | | | | | | 2)NOTE: PLEASE SEE BLDG PLAN REVIEW | | | NOTES. PLEASE CORRELATE PLANS/PAPERWORK | | | FOR COTTAGES. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-05-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-05-15 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-05-15 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2003-05-15 00:00:00 | NOTES UNDER MAIN 02102207 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2003-07-22 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-07-22 |
Time |
09:47 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2003-07-22 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2003-07-22 00:00:00 | PASSED: | | | 1. SEE PERMIT # 02102208 FOR UNDERGROUND | | | UTILITIES AND SITE WORK. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-05-31 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-05-31 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-05-31 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2006-05-31 00:00:00 | ***PROVISO*** | | | | | | REVISIONS | | | | | | 1) DUCT SMOKE DETCTOR INSTALLATIONS | | | SHALL INITIATE A GENERAL FIRE ALARM IN | | | ACCORDANCE WITH LOCAL REQUIREMENTS. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-09-19 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-09-19 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-09-19 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2003-09-19 00:00:00 | APPROVED PROVISO: | | | | | | PLEASE PROVIDE THIS OFFICE A LETTER | | | HOW THE COTTAGES WILL BE LICENSED UNDER | | | STATE, COUNTY, AND CITY REQUIREMENTS. | | | | | | PLEASE INDICATE HOURS OF OPERATION FOR | | | THE COTTAGES. (FULL OR PART TIME) | | | | | | WILL THERE BE ANY COOKING PLANNED AT | | | THE COTTAGE THAT WOULD CREATE SMOKE | | | OR GREASE LADEN VAPORS. | | | | | | THE SAME COMMENTS APPLY TO PERMIT | | | NUMBERS 03050050, 03050051, 03050052, | | | 03050053, 03050054, 03050055, 03050056, | | | 03050057, AND MASTER PERMIT # 021002207. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-06-24 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-06-24 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-06-24 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2003-06-24 00:00:00 | ***********DENIED*********** | | | 1) AGAIN HOW WILL THE COTTAGES BE | | | LICENSED UNDER STATE, COUNTY AND CITY | | | REQUIREMENTS. | | | | | | 2) PLEASE INDICATE HOURS OF OPERATION | | | FOR THE COTTAGES. (FULL TIME OR PART | | | TIME) | | | | | | 3) WILL THERE BE ANY COOKING PLANNNED AT | | | THE COTTAGES THAT WOULD CREATE SMOKE OR | | | GREASE LADEN VAPORS. | | | | | | 4) ABOVE COMMENTS ARE ALSO FOR PERMITS | | | (03050050; 03050051; 03050052; 03050053; | | | 03050054; 03050055; 03050056; 03050057 | | | MASTER PERMIT # 021002207). | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-11-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-09 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-09 |
Time |
17:52 |
Sent To |
E |
|
| Notes |
| 2006-11-09 17:52:56 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-11-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-04 |
Time |
19:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-04 |
Time |
19:17 |
Sent To |
P |
|
| Notes |
| 2006-11-04 19:17:59 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-08-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-14 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-14 |
Time |
13:51 |
Sent To |
M |
|
| Notes |
| 2006-08-14 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-20 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-20 |
Time |
08:16 |
Sent To |
M |
|
| Notes |
| 2006-06-20 00:00:00 | TO "PKRAUSS" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-05-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-16 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-16 |
Time |
15:49 |
Sent To |
E |
|
| Notes |
| 2006-05-16 00:00:00 | TO "DPALMER' DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-03-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-28 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-28 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2006-06-09 00:00:00 | 6/8/06-TAKEN FROM "COMM" BD#51 TO | | | "RBROWN" DESK | | 2006-04-18 00:00:00 | TO "COMM" BD#51-REV | | 2006-03-28 00:00:00 | WAITING FOR "COMM" BD-REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-23 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-23 |
Time |
16:08 |
Sent To |
B |
|
| Notes |
| 2006-01-23 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-23 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-23 |
Time |
16:01 |
Sent To |
B |
|
| Notes |
| 2006-01-23 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-02-24 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2005-02-03 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2005-02-03 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2005-02-24 00:00:00 | PLANS ON RACK (COMMERCIAL BOARD #17) |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-02-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-06 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-06 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2004-02-06 00:00:00 | TO COMM BD#45 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-09-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-12 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-12 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2003-09-12 00:00:00 | COMM BD#42/PLANS ON RACK SHELF 4 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-05-05 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-05 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-05 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2003-05-05 00:00:00 | COMM BOARD #12,PLANS NEXT TO CONF ROOM |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-09-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-09-11 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-09-11 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2006-09-11 00:00:00 | PROVISO: | | | GENERAL NOTES: REVISION ADDED NOTE #4 | | | WHICH INDICATES THE HVAC CLOSET WILL NOW | | | SERVE AS A PLENUM AND ALL DEVICES | | | LOCATED IN THE SPACE SHALL BE PLENUM | | | RATED.PLEASE NOTE, THIS SHALL INCLUDE | | | THE DOOR AND DOOR FRAME. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719 OR | | | E-MAIL [email protected]. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-10-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-10-28 |
Time |
07:45 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-10-28 |
Time |
07:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-05-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-05-10 |
Time |
12:18 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-05-10 |
Time |
12:18 |
Sent To |
|
|
| Notes |
| 2003-05-10 00:00:00 | MECHANICAL PERMIT 03050406 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
|
Date |
2006-11-07 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-11-07 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-11-07 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2006-11-07 14:29:55 | AS BUILT REVISIION FOR DWVU/G |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-03-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-05 |
Time |
06:13 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2005-03-05 |
Time |
06:13 |
Sent To |
|
|
| Notes |
| 2005-03-05 00:00:00 | PASSED/PROVISO | | | | | | | | | PLUMBING APPROVAL ONLY.SEPARATE PERMIT | | | REQUIRED FOR GAS. MORE INFORMATION WILL | | | BE REQUIRED WHEN APPLYING FOR PERMIT. | | | - SPECIFICATION SHEET FOR ADA ACCESSIBLE | | | SLIDING DOOR HARDWARE FOR DOOR AT ROOM | | | #104A REQUIRED AT TIME OF FINAL INSPECT- | | | ION. | | | | | | | | | PLUMBING PROVISO | | | | | | SHT P6-3.01 WATER HAMMER ARRESTORS ARE | | | REQUIRED ON THE WATER SUPPLY PIPING FOR | | | THE WASH MACHINES. SECTION 604.9 LOCATED | | | PER PDI-WH 201 NEAR THE FIXTURES. | | | | | | SHT P6-3.01 FULL OPEN VALVES ARE | | | REQUIRED ON THE TOP OF ALL WATER | | | DOWN-FEED PIPES PER SECTION 606.1(4) | | | | | | SHT P6-3.02 CLEANOUTS ARE REQUIRED AT | | | THE WASH MACHINES MINIMUM 4' ABOVE THE | | | FLOOR FOR ACCESS. SECTION 708.10 | | | | | | | | | | | | . |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-06-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-07 |
Time |
15:40 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-06-07 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2003-06-07 00:00:00 | SEE PERMIT #02102207 - SEE PROVISO |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-05-12 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-11-06 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2003-11-06 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2005-05-12 00:00:00 | OK PER JOSH LONG, PLANNER MM |
|
|