Plan Review Details - Permit 03050047
Plan Review Stops For Permit 03050047
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-05-09 Cont ID  
Sent By btrobaug Date 2003-11-12 Time 11:38 Rev Time 16.00
Received By lmartine Date   Time   Sent To M
Notes
2003-05-08 00:00:00 
 DESIGN PROFESSIONAL SHALL SIGN AND
 SEAL ALL PAGES
  
  
  
 L.MARTINEZ
 805-6710

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-11-12 Cont ID  
Sent By btrobaug Date 2003-11-12 Time 11:38 Rev Time 0.50
Received By btrobaug Date 2003-11-12 Time 10:45 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-05-20 Cont ID  
Sent By dpalmer Date 2003-05-20 Time 15:44 Rev Time 0.50
Received By dpalmer Date 2003-05-20 Time 15:44 Sent To B
Notes
2003-05-20 00:00:00TO LM`S DESK FOR PROCESSING.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-05-08 Cont ID  
Sent By shernand Date 2003-05-20 Time 09:29 Rev Time 1.00
Received By btrobaug Date 2003-05-08 Time 17:12 Sent To  
Notes
2003-05-08 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLOWING CHANGES TO THE
 PLAN FOR CODE COMPLIANCE AND RESUBMIT
 FOR REVIEW.
  
 1} THE 2 POLE 55AMP BREAKER ON THE PANEL
 SCHEDULE FOR AHU #1 IS INCORRECT PER
 240-6,MUST BE A 60 AMP.
  
 2} THERE ARE EXCESSIVE LOADS IN THE
 CALC'S FOR THE GAS APPLIANCES.PLEASE
 CHANGE TO INDICATE THE CORRECT LOADS
 AND VERIFY IF THEY ARE GAS OR ELECTRIC.
  
 3} THE RECEPTACLE FOR THE WHIRLPOOL MUST
 BE SHOWN AS GFI PER 680.
  
 4} PLEASE NOTE KITCHEN COUNTER-
 SPACE RECEPT SPACING SHALL MEET ART;
 210-52C 1,2,3,4,AND 5.AND BE SHOWN ON
 THE PLAN TO BE GFI PER 210-8(A)(6).
  
 5} SHOW HOW THE LOGGIA EGRESS MEETS
 210-70.
  
 6} PLEASE SHOW ALL OUTLET SPACING
 TO MEET 2',6',12' RULE PER 210-52.
 SEE REDLINED DRAWINGS.
  
 7} THERE IS A SUB PANEL SHOWN IN THE
 GARAGE BUT NO PANEL SCHEDULE FOR
 SAME.PLEASE PROVIDE A PANEL SCHEDULE
 PER 215-5.
  
 8} THERE IS NO FEED SHOWN TO THE SUB
 PANEL FROM THE ELECTRIC PANEL. INDICATE
 HOW IT IS FED
  
 9} THE "POWDER ROOM" MUST HAVE A GFI
 RECEPTACLE TO COMPLY WITH 210-52(D).
  
 10} PLEASE NOTE THAT PLANS ARE TO
 BE SIGNED, DATED AND SEALED BY AN P.E.
 PER FS/FAC 553-79-6A.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/508-6718

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-05-20 Cont ID  
Sent By shernand Date 2003-05-20 Time 09:29 Rev Time 0.00
Received By shernand Date 2003-05-20 Time 09:29 Sent To E
Notes
2003-05-20 00:00:00BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-08 Cont ID  
Sent By shernand Date 2003-05-08 Time 12:31 Rev Time 0.00
Received By shernand Date 2003-05-08 Time 12:31 Sent To  
Notes
2003-05-08 00:00:00LMARTINEZ DESK

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-05-10 Cont ID  
Sent By lmartine Date 2003-05-09 Time 08:40 Rev Time 0.30
Received By pkrauss Date 2003-05-10 Time 08:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-11-12 Cont ID  
Sent By kstevens Date 2003-11-12 Time 13:11 Rev Time 0.25
Received By kstevens Date 2003-11-12 Time 13:11 Sent To  
Notes
2003-11-12 00:00:00RESTAMP PLANS FOR O/B

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-05-14 Cont ID  
Sent By kstevens Date 2003-05-14 Time 16:36 Rev Time 0.50
Received By kstevens Date 2003-05-14 Time 16:36 Sent To  
Notes
2003-05-14 00:00:00PASSED/PROVISO
  
 ALL CAPPED PIPES SHALL BE INSPECTED
 PRIOR TO COVERING.

Review Stop Z ZONING
Rev No 1 Status N Date 2003-05-08 Cont ID  
Sent By lmartine Date 2003-05-08 Time 16:38 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***