| Plan Review Stops For Permit 03050042 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-07-15 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-07-15 |
Time |
17:21 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-07-15 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2003-07-15 00:00:00 | ****PROVISO***** | | | | | | READ SOILS REPORT REGARDING COMPACTION | | | BEFORE COMMENCEMENT. | | | | | | SUBMIT PRODUCT APPROVAL FOR EXTERIOR | | | DOOR. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-07-03 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-15 |
Time |
13:48 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-07-02 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2003-07-03 00:00:00 | *******CORRECTIONS******* | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SUBMIT 2 COPIES OF PRODUCT | | | APPROVALS FOR THE EXTERIOR DOOR AND | | | SHUTTERS. | | | | | | 2.)PROVIDE A SOILS INVESTIGATION | | | REPORT. | | | | | | 3.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 4.)SIGN THE ENERGY CALC ON THE OWNER/ | | | AGENT LINE. | | | | | | 5.)ADDITIONAL FEES REQUIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-05-27 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-01 |
Time |
15:24 |
Rev Time |
2.00 |
| Received By |
sthyng |
Date |
2003-05-23 |
Time |
18:32 |
Sent To |
|
|
| Notes |
| 2003-05-23 00:00:00 | *******CORRECTIONS********* | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE ORIGINAL RECEIPT ATTACHED. | | | 233-5025 | | | | | | 2.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE | | | A PERMIT CAN BE ISSUED. | | | | | | 3.)THE TRUSS CONNECTOR UPLIFT VALUES | | | AND NAILING SCHEDULES ARE INCORRECT. | | | REFER TO SIMPSON 2003 CATALOG. | | | | | | 4.)SUBMIT TWO COPIES OF PRODUCT | | | APPROVALS FOR: | | | SINGLE HUNG IMPACT WINDOW | | | EXTERIOR DOOR | | | AWNING SHUTTER | | | TILE ROOF | | | | | | 5.)FIRESTOP REQUIRED FBC 705.3. | | | | | | 6.)PROVIDE A SOILS INVESTIGATION | | | REPORT. | | | | | | 7.)SIGN THE ENERGY CALC ON THE | | | OWNER/AGENT LINE. | | | | | | 8.)ADDITIONAL FEES REQUIRED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-05-13 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-09 |
Time |
11:28 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2003-05-13 |
Time |
07:56 |
Sent To |
P |
|
| Notes |
| 2003-05-13 00:00:00 | PROVISO | | | ~~~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE CHECK THE NAMEPLATE RATINGS OF | | | BOTH AIR HANDLERS AND USE THE CORRECT | | | OVERCURRENT PROTECTION FOR SAME. | | | ALSO CORRECT THE WATER HEATER CIRCUIT | | | AND USE CORRECT WIRE AND OCP FOR SAME. | | | HAVE FIELD INSPECTOR VERIFY CORRECTIONS | | | ON ROUGH INSPECTION. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-07-15 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-15 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-15 |
Time |
13:48 |
Sent To |
B |
|
| Notes |
| 2003-07-15 00:00:00 | STHYNG DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-07-01 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-01 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-01 |
Time |
15:24 |
Sent To |
B |
|
| Notes |
| 2003-07-01 00:00:00 | STHYNG DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-05-09 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-09 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-09 |
Time |
11:28 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-05-02 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-05-07 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-02 |
Time |
16:13 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-05-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-19 |
Time |
06:50 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-05-20 |
Time |
10:54 |
Sent To |
B |
|
| Notes |
| 2003-05-20 00:00:00 | PROVISO: | | | | | | A/C FOR ADDITION IS APPROVED.PLEASE | | | PROVIDE INFORMATION OF THE EXISTING A/C | | | SYSTEM.PLAN INDICATES AN ADDITIONAL | | | 340 CFM TO THE EXISTING SYSTEM.PLEASE | | | PROVIDE TOTAL SQ FT THAT THIS SYSTEM | | | SERVES & MAKE, MODEL BTU OF THE EXISTING | | | A/C SYSTEM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-05-13 |
Time |
08:27 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-05-19 |
Time |
06:50 |
Sent To |
M |
|
| Notes |
| 2003-05-19 00:00:00 | PASSED/PROVISO | | | | | | C/O REQUIRED 4' AFF AT W/M - STAND PIPE | | | REQD AT W/M - PER FBC-2001 PLUMBING - | | | AIR CHAMBERS NOT APPROVED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-05-07 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-02 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|