Plan Review Details - Permit 03050042
Plan Review Stops For Permit 03050042
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-07-15 Cont ID  
Sent By sthyng Date 2003-07-15 Time 17:21 Rev Time 1.00
Received By sthyng Date 2003-07-15 Time 16:45 Sent To  
Notes
2003-07-15 00:00:00****PROVISO*****
  
 READ SOILS REPORT REGARDING COMPACTION
 BEFORE COMMENCEMENT.
  
 SUBMIT PRODUCT APPROVAL FOR EXTERIOR
 DOOR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-07-03 Cont ID  
Sent By shernand Date 2003-07-15 Time 13:48 Rev Time 1.00
Received By sthyng Date 2003-07-02 Time 10:23 Sent To  
Notes
2003-07-03 00:00:00*******CORRECTIONS*******
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)SUBMIT 2 COPIES OF PRODUCT
 APPROVALS FOR THE EXTERIOR DOOR AND
 SHUTTERS.
  
 2.)PROVIDE A SOILS INVESTIGATION
 REPORT.
  
 3.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 4.)SIGN THE ENERGY CALC ON THE OWNER/
 AGENT LINE.
  
 5.)ADDITIONAL FEES REQUIRED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-05-27 Cont ID  
Sent By shernand Date 2003-07-01 Time 15:24 Rev Time 2.00
Received By sthyng Date 2003-05-23 Time 18:32 Sent To  
Notes
2003-05-23 00:00:00*******CORRECTIONS*********
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE STAMPED
 AND THE ORIGINAL RECEIPT ATTACHED.
 233-5025
  
 2.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE
 A PERMIT CAN BE ISSUED.
  
 3.)THE TRUSS CONNECTOR UPLIFT VALUES
 AND NAILING SCHEDULES ARE INCORRECT.
 REFER TO SIMPSON 2003 CATALOG.
  
 4.)SUBMIT TWO COPIES OF PRODUCT
 APPROVALS FOR:
 SINGLE HUNG IMPACT WINDOW
 EXTERIOR DOOR
 AWNING SHUTTER
 TILE ROOF
  
 5.)FIRESTOP REQUIRED FBC 705.3.
  
 6.)PROVIDE A SOILS INVESTIGATION
 REPORT.
  
 7.)SIGN THE ENERGY CALC ON THE
 OWNER/AGENT LINE.
  
 8.)ADDITIONAL FEES REQUIRED.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-05-13 Cont ID  
Sent By shernand Date 2003-05-09 Time 11:28 Rev Time 0.75
Received By btrobaug Date 2003-05-13 Time 07:56 Sent To P
Notes
2003-05-13 00:00:00PROVISO
 ~~~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE CHECK THE NAMEPLATE RATINGS OF
 BOTH AIR HANDLERS AND USE THE CORRECT
 OVERCURRENT PROTECTION FOR SAME.
 ALSO CORRECT THE WATER HEATER CIRCUIT
 AND USE CORRECT WIRE AND OCP FOR SAME.
 HAVE FIELD INSPECTOR VERIFY CORRECTIONS
 ON ROUGH INSPECTION.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-07-15 Cont ID  
Sent By shernand Date 2003-07-15 Time 13:48 Rev Time 0.00
Received By shernand Date 2003-07-15 Time 13:48 Sent To B
Notes
2003-07-15 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-01 Cont ID  
Sent By shernand Date 2003-07-01 Time 15:24 Rev Time 0.00
Received By shernand Date 2003-07-01 Time 15:24 Sent To B
Notes
2003-07-01 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-05-09 Cont ID  
Sent By shernand Date 2003-05-09 Time 11:28 Rev Time 0.00
Received By shernand Date 2003-05-09 Time 11:28 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-02 Cont ID  
Sent By sgraham Date 2003-05-07 Time 10:16 Rev Time 0.00
Received By shernand Date 2003-05-02 Time 16:13 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-05-20 Cont ID  
Sent By kstevens Date 2003-05-19 Time 06:50 Rev Time 0.40
Received By pkrauss Date 2003-05-20 Time 10:54 Sent To B
Notes
2003-05-20 00:00:00PROVISO:
  
 A/C FOR ADDITION IS APPROVED.PLEASE
 PROVIDE INFORMATION OF THE EXISTING A/C
 SYSTEM.PLAN INDICATES AN ADDITIONAL
 340 CFM TO THE EXISTING SYSTEM.PLEASE
 PROVIDE TOTAL SQ FT THAT THIS SYSTEM
 SERVES & MAKE, MODEL BTU OF THE EXISTING
 A/C SYSTEM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-05-19 Cont ID  
Sent By btrobaug Date 2003-05-13 Time 08:27 Rev Time 0.33
Received By kstevens Date 2003-05-19 Time 06:50 Sent To M
Notes
2003-05-19 00:00:00PASSED/PROVISO
  
 C/O REQUIRED 4' AFF AT W/M - STAND PIPE
 REQD AT W/M - PER FBC-2001 PLUMBING -
 AIR CHAMBERS NOT APPROVED.

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-07 Cont ID  
Sent By shernand Date 2003-05-02 Time 16:13 Rev Time 0.00
Received By sgraham Date   Time   Sent To I
Notes
***NONE***