Plan Review Details - Permit 03050019
| Plan Review Stops For Permit 03050019 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-07-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-07-14 |
Time |
12:30 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2003-07-14 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2003-07-14 00:00:00 | | | | *** ISSUED PERMIT*** | | | -PLAN REVIEW HISTORY- | | | | | | PERMIT# 03050019 | | | ADDRESS: 1302 PARKER AVE | | | CONT: THE WHITING TURNER | | | TELL # (561)832-4995 | | | | | | THE ATTACHED COMMENTS ARE PART OF THE | | | PERMIT AND PLAN REVIEW PACKAGE AND ARE | | | NOT TO BE REMOVED FROM THE ISSUED SET OF | | | PLANS.104.2.1.2 ADMINISTRATIVE CODE. | | | | | | ACTION : REVIEWED | | | | | | ******PROVISO******* | | | | | | 1) NO PLAYGROUND EQUIPMENT IN PHASE 4 | | | AMENDMENT 2 | | | 2) NO GAZEBO NOR PICNIC PAVILION TO BE | | | IN THIS PHASE. | | | 00) AIR CHAMBERS ARE NOT APPROVED. WATER | | | HAMMER ARRESTORS SHALL BE REQUIRED FOR | | | QUICK CLOSING VALVES. IF INSTALLED THEY | | | SHALL BE LOCATED NEAR THE FIXTURE IN AN | | | "EFFECTIVE RANGE" NOT AT THE TOP OF THE | | | DROP. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-02 |
Time |
11:29 |
Rev Time |
0.66 |
| Received By |
jwitmer |
Date |
2003-05-19 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2003-05-19 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 03050019 | | | ADD: 1703 S LAKE AVE | | | CONT: WHITING TURNER | | | TEL: (561) 832-4995 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | ACTION: DENIED | | | | | | 1) REQUIRES HISTORICS APPROVAL. | | | | | | 2) PLANS INDICATE WORK TO BE ACCOMPLISH- | | | ED UNDER THIS PERMIT AS PHASE 4, | | | NO INFORMATION ON THE GAZEBO OR ON THE | | | CHILDRENS PLAYGROUND EQUIPMENT OR ON THE | | | WALKING SURFACES (MULCH) AS BEING ACCESS | | | IBLE. | | | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | JIM WITMER | | | BUILDING PLAN REVIEW | | | TEL: (561)659-8096 X 8412 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-05-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-05-08 |
Time |
13:15 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-05-08 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2003-05-08 00:00:00 | ********** NOTE REDLINED ********** | | | | | | NO EQUIPMENT GROUNDIING CONDUCTOR IS TO | | | BE SHOWN FROM METER TO FIRST MEANS OF | | | DISC. 250-24 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2003-05-08 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-05-08 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
mamini |
Date |
2003-05-08 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-07-02 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-02 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-02 |
Time |
11:28 |
Sent To |
B |
|
| Notes |
| 2003-07-02 00:00:00 | JW DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-05-05 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-05-06 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-05 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2003-05-05 00:00:00 | COMM BOARD #15. NOTIFIED ROBIN SINGER | | | OF ZONING REVIEW |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-05-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-27 |
Time |
11:46 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-05-27 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2003-05-27 00:00:00 | SEE NOTES SHEET I1 OF 4 - IRRIGATION | | | PERMIT REQUIRED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-05-06 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-05 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
|