Plan Review Details - Permit 03042753
Plan Review Stops For Permit 03042753
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-10-14 Cont ID  
Sent By sthyng Date 2003-10-14 Time 15:12 Rev Time 0.50
Received By sthyng Date 2003-10-14 Time 15:12 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-10-10 Cont ID  
Sent By sthyng Date 2003-10-10 Time 10:07 Rev Time 2.00
Received By sthyng Date 2003-10-10 Time 10:07 Sent To  
Notes
2003-10-10 00:00:00*****CORRECTIONS*****
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)SEE PREVIOUS LIST, PROVIDE A SOILS
 INVESTIGATION REPORT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-07-23 Cont ID  
Sent By csiegber Date 2003-10-08 Time 12:28 Rev Time 1.50
Received By sthyng Date 2003-07-23 Time 15:42 Sent To  
Notes
2003-07-23 00:00:00******CORRECTIONS******
  
 1.)ADDITIONAL PERMITS REQUIRED.
  
 2.)SEE PREVIOUS LIST, #2, SHOW THE
 CLEAR NET OPENING HEIGHT (FROM THE
 MANUFACTURER) OF THE SINGLE HUNG 60"
 HIGH EGRESS WINDOWS TO SHOW COMPLIANCE
 WITH FBC1005.4.
  
 3.)SEE PREVIOUS LIST #10, PROVIDE A
 HURRICANE SHUTTER ANCHORING SCHEDULE.
  
 4.)PAGE 3 OF THE ROOF PRODUCT APPROVAL
 IS MISSING.
  
 2.)THE PRODUCT APPROVAL FOR THE
 OPAQUE DOOR IS MISSING SHEETS REFERRED
 TO IN ITEM 2.1.
  
 3.)THE SINGLE HUNG WINDOW PRODUCT
 APPROVAL IS EXPIRED.
  
 4.)PROVIDE A PRODUCT APPROVAL FOR
 DOOR #5.
  
 5.)PROVIDE A SOILS INVESTIGATION
 REPORT.
  
 6.)SEE PREVIOUS LIST REGARDING IMPACT
 FEES, ITEM #14.
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-06-17 Cont ID  
Sent By alange Date 2003-07-22 Time 15:05 Rev Time 3.00
Received By sthyng Date 2003-06-16 Time 14:55 Sent To  
Notes
2003-06-17 00:00:00******CORRECTIONS********
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)SEPARATE PERMITS REQUIRED.
  
 2.)SHOW THE CLEAR NET OPENING HEIGHT
 (FROM THE MANUFACTURER) OF THE SINGLE
 HUNG 60" HIGH EGRESS WINDOWS TO SHOW
 COMPLIANCE WITH FBC1005.4.
  
 3.)ADDITIONAL FEES DUE, $376.61 (SEE
 ATTACHED FOR VALUATION ADJUSTMENT).
  
 4.)INSULATION ON THE WALLS ARE TO BE
 A MINIMUM OF 4.2 PER ENERGY CALCS;
 REVISE WALL SECTION.
  
 5.)UPLIFT FOR TRUSS ANCHORS
 SPECIFIED EXCEEDS UPLIFT ALLOWED IN THE
 2003 CATALOG.REVISE.
  
 6.)FOOTER IS REQUIRED TO BE A MINIMUM
 OF 12" BELOW GRADE PER FBC 1804.1.3.
  
 7.)SPECIFY THE SPACING OF SOFFIT
 SCREEN VENTS, COMPLY WITH FBC 2309.7.
  
 8.)INSULATION BETWEEN CONDITIONED AND
 UNCONDITIONED SPACE IS REQUIRED PER
 ENERGY CALC (ADJACENT WALL).
  
 9.)PROVIDE A WINDOW AND DOOR BUCK
 ATTACHMENT DETAIL; COMPLY WITH FBC
 1707.4.4.2.
  
 10.) PROVIDE A HURRICANE SHUTTER
 ANCHORING SCHEDULE, SEE ATTACHED.
  
 11.) SPECIFY DESIGN PRESSURE FOR DOOR
 #5.
  
 12.)PROVIDE TWO COPIES OF THE GARAGE
 DOOR PRODUCT APPROVAL.
  
 13.)PROVIDE DESIGN INFORMATION ON THE
 PLAN, FBC 1606.1.7.
  
 14.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE
 STAMPED AND THE ORIGINAL RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 233-5025

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-06-05 Cont ID  
Sent By shernand Date 2003-06-04 Time 16:32 Rev Time 0.50
Received By btrobaug Date 2003-06-04 Time 16:44 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-10-08 Cont ID  
Sent By csiegber Date 2003-10-08 Time 12:28 Rev Time 0.00
Received By csiegber Date 2003-10-08 Time 12:28 Sent To B
Notes
2003-10-08 00:00:00TO ST DESK

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-07-23 Cont ID  
Sent By alange Date 2003-07-23 Time 15:51 Rev Time 0.00
Received By alange Date 2003-07-22 Time 15:05 Sent To B
Notes
2003-07-22 00:00:007/22/03 TO STHYNG ALANGE

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-06-05 Cont ID  
Sent By shernand Date 2003-06-05 Time 10:52 Rev Time 0.00
Received By shernand Date 2003-06-05 Time 10:52 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-06-04 Cont ID  
Sent By btrobaug Date 2003-06-05 Time 10:51 Rev Time 0.00
Received By shernand Date 2003-06-04 Time 16:32 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-05-08 Cont ID  
Sent By shernand Date 2003-05-08 Time 11:46 Rev Time 0.00
Received By shernand Date 2003-05-08 Time 11:46 Sent To Z
Notes
2003-05-08 00:00:00SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-30 Cont ID  
Sent By shernand Date 2003-04-30 Time 09:39 Rev Time 0.00
Received By shernand Date 2003-04-30 Time 09:39 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-06-16 Cont ID  
Sent By kstevens Date 2003-06-07 Time 16:34 Rev Time 0.20
Received By pkrauss Date 2003-06-16 Time 14:34 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-06-07 Cont ID  
Sent By shernand Date 2003-06-05 Time 10:52 Rev Time 0.25
Received By kstevens Date 2003-06-07 Time 16:34 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-06-03 Cont ID  
Sent By shernand Date 2003-05-08 Time 11:46 Rev Time 0.00
Received By mmclean Date   Time   Sent To  
Notes
2003-04-30 00:00:00DENIED, PUT SITE PLAN ON SURVEY TO
 SCALE