Plan Review Details - Permit 03042120
Plan Review Stops For Permit 03042120
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-07-15 Cont ID  
Sent By jwitmer Date 2003-07-15 Time 10:05 Rev Time 2.00
Received By jwitmer Date 2003-07-15 Time 10:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-06-02 Cont ID  
Sent By btrobaug Date 2003-07-14 Time 16:22 Rev Time 2.00
Received By jwitmer Date 2003-06-02 Time 16:21 Sent To  
Notes
2003-06-02 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03042120
 ADD: 8016 CRANES POINTE WAY
 CONT: SHELDON FRIEFELD INC
 TEL: (561)722-5078
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ACTION: DENIED
  
  
 SAME COMMENTS /SAME MODEL AS 03042122.
 JIM WITMER

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-01-20 Cont ID  
Sent By btrobaug Date 2004-01-20 Time 13:30 Rev Time 0.50
Received By btrobaug Date 2004-01-20 Time 13:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-07-14 Cont ID  
Sent By btrobaug Date 2004-01-20 Time 13:29 Rev Time 0.50
Received By btrobaug Date 2003-07-14 Time 16:03 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-07-02 Cont ID  
Sent By shernand Date 2003-07-11 Time 16:57 Rev Time 0.50
Received By btrobaug Date 2003-07-02 Time 08:59 Sent To B
Notes
2003-07-02 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE NOTE THAT THE GROUNDING
 ELECTRODE CONDUCTOR MUST BE INSTALLED
 PER 250.64C,AND BE #2.REMOVE #4.
  
 PLEASE NOTE THAT ALL PLANS
 DRAWN BY AN ARCHITECT/ENGINEER CONTAIN-
 ING A TITLE BLOCK, MUST BE SIGNED,
 DATED AND SEALED BY THE ARCH/ENGINEER OF
 RECORD. PER FS/FAC 481.221 & 471.025
 A RUBBER STAMP IS NOT ACCEPTABLE AS A
 SIGNATURE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-05-14 Cont ID  
Sent By sgraham Date 2003-04-30 Time 11:59 Rev Time 0.50
Received By btrobaug Date 2003-05-14 Time 09:34 Sent To P
Notes
2003-05-14 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} SHOW THE LOCATION OF THE SERVICE
 EQUIPMENT ON THE DRAWINGS.
  
 2} THERE IS NO PANEL SCHEDULE FOR PANEL
 "B".
  
 3} ADD A RECPTACLE IN THE BREAKFAST AREA
 PER 210-52(A)(1).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-01-20 Cont ID  
Sent By btrobaug Date 2004-01-20 Time 13:28 Rev Time 0.00
Received By btrobaug Date 2004-01-20 Time 13:28 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-08-06 Cont ID  
Sent By alange Date 2003-08-06 Time 15:18 Rev Time 0.00
Received By alange Date 2003-08-06 Time 15:18 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-11 Cont ID  
Sent By shernand Date 2003-07-11 Time 16:57 Rev Time 0.00
Received By shernand Date 2003-07-11 Time 16:57 Sent To E
Notes
2003-07-11 00:00:00JW DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-25 Cont ID  
Sent By shernand Date 2003-06-25 Time 10:57 Rev Time 0.00
Received By shernand Date 2003-06-25 Time 10:57 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-28 Cont ID  
Sent By shernand Date 2003-04-28 Time 10:38 Rev Time 0.00
Received By shernand Date 2003-04-28 Time 10:38 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-05-21 Cont ID  
Sent By kstevens Date 2003-06-30 Time 09:42 Rev Time 0.25
Received By pkrauss Date 2003-05-21 Time 08:30 Sent To B
Notes
2003-05-21 00:00:00PROVISO:MECH PERMIT 03042129
  
 GAS DRYER IN LAUNDRY ROOM - PLEASE
 PROVIDE CALCULATIONS FOR COMBUSTION AIR
 IF REQUIRED AS PER 2001 FBC(M) 702 OR
 703.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-08-12 Cont ID  
Sent By kstevens Date 2003-08-12 Time 08:01 Rev Time 0.50
Received By kstevens Date 2003-08-12 Time 08:01 Sent To  
Notes
2003-08-12 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-06-30 Cont ID  
Sent By alange Date 2003-08-06 Time 15:18 Rev Time 0.33
Received By kstevens Date 2003-06-30 Time 09:42 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-05-17 Cont ID  
Sent By shernand Date 2003-06-25 Time 10:57 Rev Time 0.33
Received By kstevens Date 2003-05-17 Time 07:39 Sent To M
Notes
2003-05-17 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SANITARY RISER DIAGRAM DOES NOT MEET
 CODE REQUIREMENTS. - BIDET IN MASTER
 BATH IS NOT VENTED. KITCHEN SINK IS
 MISLABELED AS LAV. - DISHWASHER SHALL
 TIE IN UPSTREAM OF TRAP. - WASH MACHINE
 SHALL TIE IN DOWNSTREAM OF LAUNDRY SINK,
 (NOT ON L/SINK WASTE ARM, AND REQUIRES A
 TRAP AND A STANDPIPE. - CLEAN OUT SHALL
 BE LOCATED 4' ABOVE FINISHED FLOOR ABOVE
 WASH MACHINE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop Z ZONING
Rev No 1 Status P Date 2003-04-30 Cont ID  
Sent By shernand Date 2003-04-28 Time 10:38 Rev Time 0.00
Received By sgraham Date   Time   Sent To E
Notes
***NONE***