Plan Review Details - Permit 03042107
Plan Review Stops For Permit 03042107
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-05-19 Cont ID  
Sent By jwitmer Date 2003-05-19 Time 14:42 Rev Time 1.11
Received By jwitmer Date 2003-05-19 Time 13:52 Sent To  
Notes
2003-05-19 00:00:00BUILDING PROVISO:
 STOREFRONT @ LOUNGE BE SAFETY GLASS!!!
 FL BLD CODE 2405.2 HAZARDOUS LOCATION
 PROVIDE SAFETY GLASS FOR THIS LOCATION:
 STOREFRONT @ LOUNGE.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-08-04 Cont ID  
Sent By dpalmer Date 2003-08-04 Time 15:08 Rev Time 0.33
Received By dpalmer Date 2003-08-04 Time 15:08 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-05-06 Cont ID  
Sent By dpalmer Date 2003-05-06 Time 12:59 Rev Time 1.25
Received By dpalmer Date 2003-05-06 Time 11:22 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-08-11 Cont ID  
Sent By nmccray Date 2003-08-11 Time 10:26 Rev Time 0.00
Received By nmccray Date 2003-08-11 Time 10:26 Sent To  
Notes
2003-08-11 00:00:00REVISION DATED 8-01-03 NAM

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2003-05-27 Cont ID  
Sent By nmccray Date 2003-05-27 Time 11:50 Rev Time 0.00
Received By nmccray Date 2003-05-27 Time 11:50 Sent To  
Notes
2003-05-27 00:00:00**************PROVISO*******************
 SEPARATE PLAN AND PERMIT APPLICATION
 WILL BE REQUIRED FOR FIRE ALARM SYSTEM
 REMODEL.
  
 NATE MCCRAY, CAPTAIN
 805-6722 OR 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-01 Cont ID  
Sent By alange Date 2003-08-01 Time 09:58 Rev Time 0.00
Received By alange Date 2003-08-01 Time 09:58 Sent To  
Notes
2003-08-01 00:00:00TO COMM BD. # 51

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-04 Cont ID  
Sent By shernand Date 2003-06-04 Time 10:24 Rev Time 0.00
Received By shernand Date 2003-06-04 Time 10:24 Sent To  
Notes
2003-06-04 00:00:00COMM BOARD #8

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-28 Cont ID  
Sent By shernand Date 2003-04-28 Time 11:22 Rev Time 0.00
Received By shernand Date 2003-04-28 Time 11:22 Sent To  
Notes
2003-04-28 00:00:00COMM BOARD #4

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-06-10 Cont ID  
Sent By pkrauss Date 2003-06-10 Time 12:18 Rev Time 0.15
Received By pkrauss Date 2003-06-10 Time 12:17 Sent To  
Notes
2003-06-10 00:00:00PLANS APPROVED 5-10-03 PHK

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-05-30 Cont ID  
Sent By pkrauss Date 2003-05-30 Time 09:23 Rev Time 0.20
Received By pkrauss Date 2003-05-30 Time 09:23 Sent To  
Notes
2003-05-30 00:00:00PER CONVERSATION W/GORDEN SCOTT (KAMM
 ENG) - TRANSFER GRILLE IS FOR ADDITIONAL
 AIR MAKE UP FOR THE AMOUNT OF EXHAUST
 AIR.GRILLE TO HAVE DAMPER, SUBMITTAL
 LTR TO FOLLOW.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-05-10 Cont ID  
Sent By pkrauss Date 2003-05-10 Time 10:44 Rev Time 0.40
Received By pkrauss Date 2003-05-10 Time 10:10 Sent To  
Notes
2003-05-10 00:00:00PROVISO:
  
 PLANS SHEET M2.1, INDICATE A TRANSFER
 GRILLE FROM THE MENS BATHROOM TO THE
 OPEN OFFICE SPACE AS PER 2001 FBC(M)
 403.2.2 AIR TRANSFER SHALL BE MAKE-UP
 AIR FOR THE EXHAUST AIR.AIR FROM THE
 BATHROOM SHALL NOT BE RECIRCULATED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-06-21 Cont ID  
Sent By kstevens Date 2003-06-21 Time 18:29 Rev Time 0.75
Received By kstevens Date 2003-06-21 Time 18:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-05-23 Cont ID  
Sent By kstevens Date 2003-05-23 Time 15:08 Rev Time 0.50
Received By kstevens Date 2003-05-23 Time 15:08 Sent To  
Notes
2003-05-23 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) SHT P0.1 WATER HEATER DETAIL, THERMAL
 EXPANSION CONTROL IS REQUIRED. PLEASE
 PROVIDE ON DETAIL. SECTION 607.3.2
 2) SHT P5.1 WATER RISER DIAGRAM. WATER
 HAMMER ARRESTORS REQUIRED BY SECTION
 604.9 SHALL BE LOCATED NEAR THE FIXTURE,
 IN AN "EFFECTIVE RANGE" NOT AT THE TOP
 OF THE DROP IN THE CEILING. PDI-WH 201
 AND MANUF. INSTALLATION INSTRUCTIONS.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692