| Plan Review Stops For Permit 03041670 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-12-29 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-12-29 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-12-29 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2003-12-29 00:00:00 | REVISION SUBMITTED 11/21/03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-05-13 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-05-13 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-05-13 |
Time |
14:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-04-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-04-01 |
Time |
13:41 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-04-01 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2004-04-01 00:00:00 | | | | UPON EXAMINATION OF THE JOB SITE, THE | | | ROOM LABLED "MAIL ROOM" IS THAT IN NAME | | | ONLY. IT WAS DETERMINED BY JAKE LEAHY | | | THAT THIS "ROOM" AND THE ELECTRICAL | | | EQUIPMENT INVOLVED IS NOT IN VIOLATION | | | OF ARTICLE 408.7 | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-12-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-12-02 |
Time |
05:30 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-12-02 |
Time |
05:28 |
Sent To |
|
|
| Notes |
| 2003-12-29 00:00:00 | ************* UNSAT ************ | | | | | | 1)NOTE: PLEASE CORRELATE ELECTRICAL | | | PLANS WITH ARCH PLANS. WALL CONFIGURAT- | | | -IONS DO NOT MATCH. | | | PLEASE ALSO SEE ORIGINAL PLANS DO NOT | | | SHOWN ELECTRICAL SERVICE EQUIPMENT IN | | | MAIL ROOM. NEW ARCH SHEET DO. | | | PLEASE SEE 408.7 FOR EQUIPMENT LOCATION | | | NOT TO BE LOCATED IN MAIL ROOM. | | | | | | PLEAS ADJUST PLANS SND SUBMIT FOR REVIEW | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2003-12-02 00:00:00 | REV DATED 11/18 OK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-05-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-05-06 |
Time |
16:33 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-05-06 |
Time |
16:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-12-10 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-12-10 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-12-10 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2003-12-10 00:00:00 | ************PROVISO********************* | | | SEPARATE PLAN AND PERMIT REQUIRED FOR | | | FIRE ALARM REMODEL. REVISION DATED NOV. | | | 21, 2003. | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2003-05-21 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-05-21 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-05-21 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2003-05-21 00:00:00 | ***************PROVISO****************** | | | FIRE ALARM SYSTEM SHALL BE CLASS "A" OR | | | FULLY ADDRESSABLE. | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-11-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-25 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-25 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2003-11-25 00:00:00 | TO COMM BD#63 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-22 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-22 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-22 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2003-04-22 00:00:00 | COMM BOARD #23 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-05-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-05-10 |
Time |
13:01 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-05-10 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2003-05-10 00:00:00 | PROVISO: | | | | | | PLANS DO NOT INDICATE RETURN AIR. | | | NO COMBUSTIBLES ABOVE CEILING IN THE | | | RETURN AIR PLENUMS. | | | | | | PROVIDE REVISED AIR CALCS IF REQUIRED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2003-05-22 |
|
|
Cont ID |
|
| Sent By |
tjonseck |
Date |
2003-05-22 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
tjonseck |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-05-22 00:00:00 | 5-22-03 OK TO PASS PER DEAN TJ |
|
|