Plan Review Details - Permit 03041551
Plan Review Stops For Permit 03041551
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2004-01-10 Cont ID  
Sent By shill Date 2004-01-10 Time 18:25 Rev Time 0.50
Received By shill Date 2004-01-10 Time 18:25 Sent To  
Notes
2004-01-10 00:00:00*****CORRECTIONS*****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 THE PLANS SUBMITTED FOR RESTAMP DO NOT
 MATCH OUR FILE SET.THE PLANS ISSUED
 FOR PERMIT HAVE 5/28/03 REVISIONS
 ADDRESSING BUILDING DEPARTMENT COMMENTS.
 THE 5/28 REVISIONS ARE NOT ON THE
 SUBMITTED SET.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-06-03 Cont ID  
Sent By shill Date 2004-01-10 Time 18:20 Rev Time 1.50
Received By sthyng Date 2003-06-03 Time 11:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-05-21 Cont ID  
Sent By shernand Date 2003-05-30 Time 15:34 Rev Time 3.00
Received By sthyng Date 2003-05-21 Time 14:20 Sent To  
Notes
2003-05-21 00:00:00******CORRECTIONS*******
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)SEPARATE PERMIT REQUIRED; ROOF.
  
 2.)UPLIFT VALUES ARE INCORRECT FOR
 THE USP CONNECTORS (A-5.1).REFER TO
 THE USP 2003 CATALOG.
  
 3.)HUGHES STRAPS ARE NO LONGER MADE;
 SPECIFY ANOTHER ATTACHMENT (AS1, GABLE
 END DETAIL).
  
 4.)THE WINDOW & SGD JAMB DETAIL MUST
 COMPLY WITH FBC 1707.4.4.2.
  
 5.)THE DESIGN PRESSURES FOR THE 9'6"
 FIXED GLASS WINDOW EXCEEDS THE PRESSURE
 ALLOWED ON THE MULLION PRODUCT APPROVAL.
  
 6.)EVERY EXTERIOR DOOR IS GLAZED. ONE
 DOOR MUST EITHER BE IMPACT, OR HAVE
 HURRICANE SHUTTERS WHICH CAN BE
 INSTALLED AND REMOVED FROM THE INSIDE.
  
 7.)ADDITIONAL FEES DUE.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-02-05 Cont ID  
Sent By btrobaug Date 2004-02-05 Time 11:12 Rev Time 0.33
Received By btrobaug Date 2004-02-05 Time 11:12 Sent To  
Notes
2004-02-05 00:00:00 
 THIS PERMIT HAS BEEN CO'D AND CLOSED IN
 OUR SYSTEM. YOU MUST APPLY FOR A NEW
 PERMIT AND HAVE THESE PLANS REVIEWED
 UNDER THAT APPLICATION.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-05-07 Cont ID  
Sent By jleech Date 2003-04-23 Time 19:35 Rev Time 0.50
Received By btrobaug Date 2003-05-07 Time 17:58 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-01-10 Cont ID  
Sent By shill Date 2004-01-10 Time 18:20 Rev Time 0.00
Received By shill Date 2004-01-10 Time 18:20 Sent To B
Notes
2004-01-10 00:00:00TO SMH DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-05-30 Cont ID  
Sent By shernand Date 2003-05-30 Time 15:34 Rev Time 0.00
Received By shernand Date 2003-05-30 Time 15:34 Sent To B
Notes
2003-05-30 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-21 Cont ID  
Sent By shernand Date 2003-04-21 Time 12:52 Rev Time 0.00
Received By shernand Date 2003-04-21 Time 12:52 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-05-16 Cont ID  
Sent By btrobaug Date 2003-05-07 Time 18:16 Rev Time 0.20
Received By pkrauss Date 2003-05-16 Time 08:31 Sent To B
Notes
2003-05-16 00:00:00APPROVED 5-13-03 MECH PERMIT 03041553

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-01-13 Cont ID  
Sent By kstevens Date 2004-01-13 Time 15:02 Rev Time 0.50
Received By kstevens Date 2004-01-13 Time 15:02 Sent To  
Notes
2004-01-13 00:00:00REVISION OK - SANT. RISER DIAGRAM.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-04-23 Cont ID  
Sent By jleech Date 2003-04-23 Time 19:35 Rev Time 0.33
Received By jleech Date 2003-04-23 Time 19:35 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-04-24 Cont ID  
Sent By shernand Date 2003-04-21 Time 12:52 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
***NONE***