| Plan Review Stops For Permit 03041551 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-01-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-01-10 |
Time |
18:25 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-01-10 |
Time |
18:25 |
Sent To |
|
|
| Notes |
| 2004-01-10 00:00:00 | *****CORRECTIONS***** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | THE PLANS SUBMITTED FOR RESTAMP DO NOT | | | MATCH OUR FILE SET.THE PLANS ISSUED | | | FOR PERMIT HAVE 5/28/03 REVISIONS | | | ADDRESSING BUILDING DEPARTMENT COMMENTS. | | | THE 5/28 REVISIONS ARE NOT ON THE | | | SUBMITTED SET. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-06-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-01-10 |
Time |
18:20 |
Rev Time |
1.50 |
| Received By |
sthyng |
Date |
2003-06-03 |
Time |
11:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-05-21 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-30 |
Time |
15:34 |
Rev Time |
3.00 |
| Received By |
sthyng |
Date |
2003-05-21 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2003-05-21 00:00:00 | ******CORRECTIONS******* | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SEPARATE PERMIT REQUIRED; ROOF. | | | | | | 2.)UPLIFT VALUES ARE INCORRECT FOR | | | THE USP CONNECTORS (A-5.1).REFER TO | | | THE USP 2003 CATALOG. | | | | | | 3.)HUGHES STRAPS ARE NO LONGER MADE; | | | SPECIFY ANOTHER ATTACHMENT (AS1, GABLE | | | END DETAIL). | | | | | | 4.)THE WINDOW & SGD JAMB DETAIL MUST | | | COMPLY WITH FBC 1707.4.4.2. | | | | | | 5.)THE DESIGN PRESSURES FOR THE 9'6" | | | FIXED GLASS WINDOW EXCEEDS THE PRESSURE | | | ALLOWED ON THE MULLION PRODUCT APPROVAL. | | | | | | 6.)EVERY EXTERIOR DOOR IS GLAZED. ONE | | | DOOR MUST EITHER BE IMPACT, OR HAVE | | | HURRICANE SHUTTERS WHICH CAN BE | | | INSTALLED AND REMOVED FROM THE INSIDE. | | | | | | 7.)ADDITIONAL FEES DUE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-02-05 |
Time |
11:12 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2004-02-05 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2004-02-05 00:00:00 | | | | THIS PERMIT HAS BEEN CO'D AND CLOSED IN | | | OUR SYSTEM. YOU MUST APPLY FOR A NEW | | | PERMIT AND HAVE THESE PLANS REVIEWED | | | UNDER THAT APPLICATION. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-05-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-04-23 |
Time |
19:35 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-05-07 |
Time |
17:58 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-01-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-01-10 |
Time |
18:20 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-01-10 |
Time |
18:20 |
Sent To |
B |
|
| Notes |
| 2004-01-10 00:00:00 | TO SMH DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-05-30 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-30 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-30 |
Time |
15:34 |
Sent To |
B |
|
| Notes |
| 2003-05-30 00:00:00 | STHYNG DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-21 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-21 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-21 |
Time |
12:52 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-05-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-05-07 |
Time |
18:16 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2003-05-16 |
Time |
08:31 |
Sent To |
B |
|
| Notes |
| 2003-05-16 00:00:00 | APPROVED 5-13-03 MECH PERMIT 03041553 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-01-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-13 |
Time |
15:02 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-01-13 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2004-01-13 00:00:00 | REVISION OK - SANT. RISER DIAGRAM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-04-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-04-23 |
Time |
19:35 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2003-04-23 |
Time |
19:35 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-04-24 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-21 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|