| Plan Review Stops For Permit 03041481 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2004-03-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-03 |
Time |
15:27 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-03-03 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2004-03-03 00:00:00 | REVISED SHEETS A2, A5, A9 1/26/04 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-02-05 |
Time |
12:17 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-02-05 |
Time |
12:17 |
Sent To |
|
|
| Notes |
| 2004-02-05 00:00:00 | *****CORRECTIONS***** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)REVISE THE WINDOW SCHEDULE TO | | | INCLUDE DOORS WW.CHECK THE DESIGN | | | PRESSURE AGAINST THE PRODUCT LIMITATIONS | | | IN THE PRODUCT APPROVAL.NOTE THAT THE | | | ELEVATIONS SHOW GLAZED DOORS; PRODUCT | | | APPROVALS SUBMITTED ARE FOR STEEL DOORS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2004-01-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-01-30 |
Time |
12:50 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-01-10 |
Time |
19:15 |
Sent To |
|
|
| Notes |
| 2004-01-10 00:00:00 | ****CORRECTIONS***** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE DESIGN PRESSURE FOR THE DOORS | | | (WW, SHEET A1) IS +51.7/-56.5.THE | | | PRODUCT APPROVALS SUBMITTED HAVE A MAX | | | PRESSURE OF +48/-51 FOR DOUBLE DOORS | | | WITH SIDELITES. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2003-11-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-05 |
Time |
16:15 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-11-21 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2003-11-21 00:00:00 | *****CORRECTIONS***** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.)DOOR WW IS NOT ON THE DOOR | | | SCHEDULE. | | | | | | 2.)SUBMIT TWO LEGIBLE COPIES OF | | | PRODUCT APPROVALS FOR THE FRENCH DOORS | | | AND SIDELITES. | | | | | | 3.)SHEETS A7 AND A8, THE NAILING FOR | | | TA21 (USP RT16) CONFLICTS WITH THE | | | CATALOG.CHECK ALL CONNECTORS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2003-11-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-11-20 |
Time |
10:23 |
Rev Time |
0.50 |
| Received By |
sthyng |
Date |
2003-11-03 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2003-11-03 00:00:00 | ****CORRECTIONS**** | | | REVISED TRUSS ANCHORING | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE TRUSS ANCHOR SCHEDULE FOR | | | SHEET A8 WAS NOT CHANGED; STILL HAS | | | THE STRESS INCREASE FOR STEEL. | | | | | | 2.)THE ARCHITECT'S LICENSE NUMBER IS | | | REQUIRED TO BE ON THE TITLE BLOCK, | | | FAC61G1-16.004. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-06-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-27 |
Time |
08:21 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-06-02 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2003-06-02 00:00:00 | *****PROVISO****** | | | REVISE SHEETS A7 & A8.REFER TO | | | 2003 CONNECTORS CATALOG. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-05-16 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-30 |
Time |
08:44 |
Rev Time |
3.00 |
| Received By |
sthyng |
Date |
2003-05-15 |
Time |
20:13 |
Sent To |
|
|
| Notes |
| 2003-05-16 00:00:00 | ********CORRECTIONS********** | | | | | | 1.)A NOTICE OF COMMENCEMENT IS | | | REQUIRED TO BE FILED WITH THE CLERK OF | | | COURTS BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.CALL 233-5025 FOR MORE | | | INFORMATION.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. | | | | | | 3.)WINDOW V REQUIRES SAFETY GLASS. | | | REVISE BOTH THE FLOOR PLAN AND THE | | | WINDOW SCHEDULE. | | | | | | 4.)THE WINDOW/SGD AND 'REPAIR | | | MASONRY GAPS' DETAILS (A12) MUST COMPLY | | | WITH FBC 1707.4.4.2. | | | | | | 5.)THE GARAGE DOOR ATTACHMENT DETAIL | | | (A12) CONFLICTS WITH THE PRODUCT | | | APPROVAL. | | | | | | 6.)THE ROOF SPECS AND SINGLE HUNG | | | WINDOW PRODUCT APPROVALS ARE ILLEGIBLE. | | | PROVIDE LEGIBLE COPIES. | | | | | | 7.)THE UPLIFT VALUES FOR SOME OF THE | | | CONNECTORS ARE INCORRECT.REFER TO | | | USP 2003 CATALOG. | | | | | | 8.)SPECIFY CEILING FINISH AT THE | | | ENTRY, WITH ATTACHMENTS. | | | | | | 9.)PROVIDE A STAIR SECTION WITH | | | FIREBLOCKING, FBC 2305.1.4. | | | | | | 10.) PROVIDE A STRUCTURAL PLAN FOR THE | | | STAIRS INDICATING HOW STAIRS AND | | | LANDING WILL BE SUPPORTED. | | | | | | 11.)PROVIDE A SOILS INVESTIGATION | | | REPORT. | | | | | | 12.)WOOD BALCONY RAILING DETAIL (A12) | | | TO COMPLY WITH FBC 1015.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2004-01-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-17 |
Time |
10:04 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-01-30 |
Time |
12:43 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2004-01-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-29 |
Time |
16:29 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-01-09 |
Time |
15:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-12-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-07 |
Time |
16:52 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-12-23 |
Time |
14:14 |
Sent To |
P |
|
| Notes |
| 2003-12-23 00:00:00 | THERE ARE NO REVISED PLANS SUBMITTED, | | | CHANGES WERE MADE ON LAST REVISION. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-11-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-23 |
Time |
08:30 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2003-11-12 |
Time |
18:01 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-06-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-07 |
Time |
16:41 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-06-20 |
Time |
17:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-05-06 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-20 |
Time |
11:04 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-05-06 |
Time |
08:38 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2004-02-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-17 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-17 |
Time |
10:01 |
Sent To |
E |
|
| Notes |
| 2004-02-17 00:00:00 | TO BT DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-29 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-29 |
Time |
16:28 |
Sent To |
E |
|
| Notes |
| 2004-01-29 00:00:00 | TO BT DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2004-01-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-07 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-07 |
Time |
16:52 |
Sent To |
E |
|
| Notes |
| 2004-01-07 00:00:00 | TO BT DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2003-12-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-23 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-23 |
Time |
08:30 |
Sent To |
E |
|
| Notes |
| 2003-12-23 00:00:00 | TO BT DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-11-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-07 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-07 |
Time |
16:40 |
Sent To |
E |
|
| Notes |
| 2003-11-07 00:00:00 | TO BT DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-10-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-27 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-27 |
Time |
08:21 |
Sent To |
B |
|
| Notes |
| 2003-10-27 00:00:00 | TO ST DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-06-20 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-20 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-20 |
Time |
11:04 |
Sent To |
E |
|
| Notes |
| 2003-06-20 00:00:00 | BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-06-04 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-04 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-04 |
Time |
14:06 |
Sent To |
B |
|
| Notes |
| 2003-06-04 00:00:00 | STHYNG DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-05-30 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-30 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-30 |
Time |
08:44 |
Sent To |
B |
|
| Notes |
| 2003-05-30 00:00:00 | STHYNG DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-21 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-21 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-21 |
Time |
09:27 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-05-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-10 |
Time |
15:28 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-05-13 |
Time |
09:50 |
Sent To |
B |
|
| Notes |
| 2003-05-13 00:00:00 | MECH PERMIT 03014520 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-01-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-05 |
Time |
16:15 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-01-05 |
Time |
16:15 |
Sent To |
B |
|
| Notes |
| 2004-01-05 00:00:00 | REVISION OK - MOVED L/T LOCATION |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-11-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-12-23 |
Time |
14:37 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-11-20 |
Time |
10:23 |
Sent To |
B |
|
| Notes |
| 2003-11-20 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) LAUNDRY SINK REQUIRES A VENT. 901.2.1 | | | 2) C/O REQ'D TO BE 4' OFF FLOOR FOR | | | ACCESS. 708.10 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-05-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-11-12 |
Time |
18:08 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-05-10 |
Time |
15:20 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-04-25 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-21 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
E |
|
| Notes |
|
|