| Plan Review Stops For Permit 03041480 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2004-03-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-03-15 |
Time |
07:01 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
2004-03-15 |
Time |
07:01 |
Sent To |
|
|
| Notes |
| 2004-03-15 00:00:00 | REVISION TO SHEETS A7 & A9 ADDING | | | LOCATION AND DETAILS OF TRUSS HANGER IS | | | OK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2003-12-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-11 |
Time |
11:28 |
Rev Time |
0.50 |
| Received By |
rmcdouga |
Date |
2003-12-12 |
Time |
12:08 |
Sent To |
P |
|
| Notes |
| 2003-12-12 00:00:00 | REVISION TO CHANGE PRIVACY FENCE TO WALL | | | AND CHANGE BEAM SIZE AT REAR PORCH |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2003-09-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2003-09-09 |
Time |
12:15 |
Rev Time |
1.50 |
| Received By |
rmcdouga |
Date |
2003-09-09 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2003-09-09 00:00:00 | REVISION TO SHEETS A1,A2,A3,A4,A5 ARE | | | OK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-06-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-08 |
Time |
13:48 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2003-06-11 |
Time |
17:30 |
Sent To |
|
|
| Notes |
| 2003-06-11 00:00:00 | BUILDING PROVISO | | | | | | 1) SUBMIT SOIL BORING TEST REPORT PRIOR | | | TO POURING THE FOUNDATION. | | | | | | 2) PAY IMPACT FEES TO COUNTY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-06-02 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-11 |
Time |
11:11 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
2003-06-02 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2003-06-02 00:00:00 | BUILDING DENIED | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3) SUBMIT A SOIL BORING TEST REPORT AS | | | REQUIRED BY CITY AMEND. TO FBC 1804.2.2. | | | | | | 4) THE 7/8" STUCCO THICKNESS REQUIRED BY | | | ASTM C 926 ON METAL LATH OVER PLYWOOD | | | SHEATHING WAS CHANGED ON THE WRONG WALL | | | SECTION ON SHEET A6. THE 5/8" STUCCO | | | OVER CONCRETE BLOCK IS ACCEPTABLE. | | | PLEASE CORRECT. | | | | | | 5) DETAIL 25 ON A8,WHICH IS SPECIFIED ON | | | SHEETS A7 AND A9, FOR THE CONNECTION OF | | | THE FLOOR GIRDER TO THE WOOD POST IN THE | | | BEARING WALL IS NOT THE CORRECT DETAIL. | | | | | | 6) THE UPLIFT VALUES FOR THE CONNECTORS | | | GIVEN IN DETAILS 24/A8, 29/A8, 32/A8 AND | | | 36/A8 ARE NOT CORRECT. SEE 2003 USP | | | CATALOG AND NOTES ON THE PLAN. | | | | | | 7) THE SECOND FLOOR BRACING PLAN ON A10 | | | SPECIFIES TC-5 AND TC-6 CONNECTORS. | | | THESE ARE NOT LISTED IN THE CONNECTOR | | | SCHEDULE ON A9. PLEASE CORRECT. | | | | | | 8) DETAIL 5/A10 IS SPECIFIED ON SHEET | | | A10. THERE AREN'T ANY DETAILS ON SHEET | | | A10. | | | | | | SEE NOTATIONS ON THE REVIEWED PLANS. | | | PLEASE RETURN OLD PAGES WITH THE NEW | | | WHEN RESUBMITTING. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-05-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-31 |
Time |
07:10 |
Rev Time |
5.00 |
| Received By |
rmcdouga |
Date |
2003-05-15 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2003-05-15 00:00:00 | BUILDING DENIED | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3) SUBMIT A SOIL BORING TEST REPORT AS | | | REQUIRED BY CITY AMEND. TO FBC 1804.2.2. | | | | | | 4) THE PRIVACY WALL FOOTING AT THE ZERO | | | LOT LINE ENCROACHES ON THE ADJACENT | | | PROPERTY. | | | | | | 5) THE FOUNDATION PLAN AND FLOOR PLAN | | | SHEETS ARE NOT NUMBERED. | | | | | | 6) THE FLOOR PLAN REFERENCES DETAIL 2 ON | | | A3 FOR THE WOOD FRAME BEARING WALL. THE | | | CORRECT DETAIL IS 3 ON A3. | | | | | | 7) DETAIL 3 ON A3 REFRENCES THE SFBC. | | | THE CURRENT CODE IS 2001 FBC. | | | | | | 8) DETAIL 1 ON A3 SPECIFIES R-11 | | | INSULATION IN THE ATTIC. THE ENERGY | | | CALCULATIONS REQUIRE R-19. | | | | | | 9) SPECIFY ON THE PLANS THAT THE BALCONY | | | GUARDRAILS ARE REQUIRED TO HAVE | | | INTERMEDIATE RAILS THAT SPACED TO REJECT | | | A 4"SPHERE AND A BOTTOM RAIL THAT WILL | | | REJECT A 2"SPHERE. SUBMIT SHOP DRAWINGS. | | | FBC 1015.3 | | | | | | 10) FIREBLOCKING IS REQUIRED AT THE | | | CONCEALED SPACES BETWEEN STAIR STRINGERS | | | AT THE TOP AND BOTTOM OF THE RUN PER | | | FBC 2305.1.4. | | | | | | 11) THE STUCCO ON METAL LATH AT THE | | | EXTERIOR WALL SECTION ON A6 IS REQUIRED | | | TO BE 7/8" THICK PER ASTM C 926. | | | | | | 12) SPECIFY ON THE PLANS THAT ADEQUATE | | | SUBSTRATE WILL BE PROVIDED AT GLAZED | | | OPENINGS IN THE WOOD FRAME WALLS FOR THE | | | ATTACHMENT OF STORM PANELS. | | | | | | 13) DETAIL 12 ON A7 SPECIFIED ON SHEET | | | A9 IS NOT THE CORRECT DETAIL FOR THE | | | GIRDER TO WOOD BEARING WALL CONNECTION. | | | | | | 14) THERE IS NO DETAIL 12 ON A8 AS | | | SPECIFIED ON SHEET A9AT THE COVERED | | | BALCONY. | | | | | | 15) THE TRUSS CONNECTORS IN THE SCHEDULE | | | ON A9, ARE ALL DESIGNED TO BE EMBEDDED | | | IN CONCRETE. THESE ARE INCORRECTLY | | | SPECIFIED AT THE WOOD FRAME WALLS AND | | | WOOD GIRDERS AT THE BALCONY. | | | | | | 16)THE CONNECTOR SCHEDULE ON A9 CONTAINS | | | INCORRECT INFORMATION. THE MANUFACTURER | | | DOES NOT ALLOW AN INCREASE IN THE LOAD | | | VALUES BY ADDING MORE NAILS THAN | | | SPECIFIED IN THE CATALOG. YOU ARE | | | ALLOWED TO SPECIFY LESS NAILS AND REDUCE | | | THE LOADS BASED ON SHEAR VALUES OF THE | | | NAILS. THE VALUES LISTED IN THE SCHEDULE | | | INCLUDE THE ONE THIRD INCREASE ON STEEL | | | ALLOWABLE STRESS DESIGN VALUES WHICH IS | | | NO LONGER ALLOWED BY FBC 1609.4.3. SEE | | | 2003 USP CATALOG. | | | | | | 17) THE STORM PANEL INFORMATION IS | | | INCORRECT. THE WRONG ANCHOR TYPE IS | | | LISTED IN THE SCHEDULE FOR OPENINGS #12, | | | 13,14,15,18 AND 19, WHICH ARE IN WOOD | | | FRAME WALLS. THE OPENINGS SIZES LISTED | | | ARE INCORRECT FOR OPENINGS #14,18 & 19. | | | THE ALLOWABLE PANEL SPANS ARE EXCEEDED | | | AT SEVERAL OPENINGS BASED ON THE SPAN | | | TABLES IN THE PRODUCT APPROVAL DRAWINGS. | | | PLEASE CORRECT. | | | | | | 18) SEE HANDWRITTEN NOTATIONS ON THE | | | REVIEWED PLAN. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-07-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-07-09 |
Time |
10:33 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-07-09 |
Time |
09:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-08-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-07 |
Time |
16:48 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-08-04 |
Time |
14:56 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-05-28 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-28 |
Time |
10:18 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-05-28 |
Time |
07:07 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-05-06 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-23 |
Time |
15:52 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2003-05-06 |
Time |
06:55 |
Sent To |
P |
|
| Notes |
| 2003-05-06 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | AND RESUBMIT FOR REVIEW. | | | | | | 1} THE #4 GEC IS INCORRECT FOR THE 400 | | | AMP SERVICE SHOWN.SHOULD BE 1/0 PER | | | 250-66. | | | | | | 2} THE FEEDER TO PANEL "B" IS MISSING AN | | | EQUIPMENT GROUND PER 250-122. | | | | | | 3} THE LAUNDRY CIRCUIT MUST BE | | | CALCULATED @ 1500 VA PER 220-16(B). | | | | | | 4} PLEASE LIST THE REQ'D BATH(S) | | | CIRCUIT(S). PER 210-11-C-3 | | | MUST BE 20A AND #12AWG. | | | | | | 5} THE SMOKE DETECTOR IN THE KITCHEN | | | DOES NOT COMPLY WITH 8-1.4.2 | | | NFPA-72.MUST BE A LISTED HEAT DETECTOR. | | | | | | 6} THE SMOKE DETECTOR AT THE DOOR OF THE | | | MASTER BEDROOM MUT BE IN THE VESTIBULE | | | TO COMPLY WITH 8-1.4.1.6(2) NFPA-72. | | | | | | 7} PANELS "A" & "B" ARE SHOWN AS 200 AMP | | | & FED AS 200 AMP ON THE RISER,BUT LIST- | | | ED AS 150 AMP ON THE SCHEDULES. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2004-07-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-07 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-07 |
Time |
16:48 |
Sent To |
E |
|
| Notes |
| 2004-07-07 00:00:00 | TO BT DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2004-03-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-11 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-11 |
Time |
11:28 |
Sent To |
B |
|
| Notes |
| 2004-03-11 00:00:00 | TO RM DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2003-09-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-08 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-08 |
Time |
13:46 |
Sent To |
B |
|
| Notes |
| 2003-09-08 00:00:00 | TO RM DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-07-28 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-28 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-28 |
Time |
10:18 |
Sent To |
E |
|
| Notes |
| 2003-07-28 00:00:00 | TO BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-07-08 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-08 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-08 |
Time |
16:27 |
Sent To |
B |
|
| Notes |
| 2003-07-08 00:00:00 | RM DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-06-27 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-27 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-27 |
Time |
16:47 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-06-11 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-11 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-11 |
Time |
11:11 |
Sent To |
B |
|
| Notes |
| 2003-06-11 00:00:00 | RM DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-05-23 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-23 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-23 |
Time |
15:52 |
Sent To |
E |
|
| Notes |
| 2003-05-23 00:00:00 | BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-21 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-21 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-21 |
Time |
10:11 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-05-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-10 |
Time |
15:32 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2003-05-13 |
Time |
09:49 |
Sent To |
B |
|
| Notes |
| 2003-05-13 00:00:00 | MECH PERMIT 03041510 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2003-12-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-12-13 |
Time |
12:00 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2003-12-13 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2003-12-13 00:00:00 | REVISED SANITARY RISER DIAGRAM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2003-07-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2003-12-12 |
Time |
12:11 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-07-03 |
Time |
16:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2003-06-14 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-27 |
Time |
16:47 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-06-14 |
Time |
07:26 |
Sent To |
|
|
| Notes |
| 2003-06-14 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SANITARY RISER DIAGRAM DOES NOT FE- | | | FLECT FLOOR PLAN. RISER SHOWS PICKING UP | | | THE POWDER ROOM PRIOR TO KITCHEN SINK, | | | SHOWS 2ND FLOOR BATHROOM REVERSED FROM | | | FLOOR LAYOUT, AND THE BAR SINK SHOWN ON | | | THE FLOOR PLAN IS MISSING FROM THE RISER | | | DIAGRAM. SECTION 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-05-31 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-31 |
Time |
07:10 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-05-31 |
Time |
07:10 |
Sent To |
B |
|
| Notes |
| 2003-05-31 00:00:00 | PASSED PROVISO - 706.3 & EXTRA DRAIN | | | LINE M/B |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-05-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-05-28 |
Time |
07:26 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-05-10 |
Time |
15:31 |
Sent To |
M |
|
| Notes |
| 2003-05-10 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SANITARY RISER DIAGRAM DOES NOT RE- | | | FLECT FLOOR PLAN. | | | 2) SEC 909.1 WASH MACHINE AND LAUNDRY | | | SINK SHALL NOT DRAIN INTO THE WET VENTED | | | HORIZONTAL DRAIN FOR THE MASTER BATH. | | | THE LAUNDRY FIXTURES SHALL TIE IN DOWN- | | | STREAM OF THE WET VENTED BATHROOM GROUP. | | | 3) THREE LAVS SHOWN FOR MASTER BATH ON | | | RISER DIAGRAM. ONLY TWO SHOWN ON FLOOR | | | PLAN. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2003-08-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2003-08-08 |
Time |
11:42 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2003-08-08 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2003-08-08 00:00:00 | REVISION TO CHANGE MASONRY PRIVACY FENCE | | | TO PVC FENCE IS OK. 8-8-03 RM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-04-25 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-21 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
E |
|
| Notes |
|
|