Plan Review Details - Permit 03041478
Plan Review Stops For Permit 03041478
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-06-18 Cont ID  
Sent By jwitmer Date 2003-06-18 Time 11:43 Rev Time 0.25
Received By jwitmer Date 2003-06-18 Time 11:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-06-16 Cont ID  
Sent By shernand Date 2003-06-17 Time 16:43 Rev Time 0.50
Received By jwitmer Date   Time   Sent To  
Notes
2003-06-16 00:00:00REQUIRES COUNTY IMPACT FEES

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-05-20 Cont ID  
Sent By kstevens Date 2003-06-14 Time 08:01 Rev Time 2.25
Received By jwitmer Date 2003-05-20 Time 12:46 Sent To  
Notes
2003-05-20 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03041478
 ADD:6222 HAMMOCK PARK RD
 CONT: DOUBLE R BUILDERS
 TEL: (954)796-0777
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 NOTE: CONTRACTOR IS CONTINEUING AT OWN
 RISK!THE SOILS REPORT SUBMITTED TO
 THIS OFFICE NOT A SEALED COPY. THIS
 REPORT INDICATES THAT THIS IS A
 "PRELIMINARY GEOTECHNICAL EVALUATION,
 UNDER LIMITATIONS(5.0) IT IS IMPORTANT
 TO REALIZE THAT THE INFORMATION PROVIDED
 IN THIS REPORT IS NOT SUFFICIENT FORA
 FINAL DESIGN OF THE FOUNDATION SYSTEM".
 RENAISSANCE SECTION # 7.
  
 2) SHEET A-1:
 A) DETAILA: PRIVACY WALL IS INDICATED
 ON ZERO-LOT LINE SIDE, FOOTER OVER PROP-
 ERTY LINE.
 B) DETAIL # 38 INDICATES THE FOUNDA-
 TION IS ONLY 8" BELOW GRADE.
 1804.1.3 THE BOTTOM OF THE FOUNDA-
 TION SHALL EXTEND NO LESS THAN 12"
 BELOW FINISH GRADE.
  
 3) SHEET A-3 EGRESS WINDOWS IN THE BED-
 ROOM # 3 & BEDROOM # 5, DO NOT MEET THE
 HEIGHT REQUIREMENT.
 2001 FL BLD CODE, 1005.4:
 PROVIDE EMERGENCY EGRESS WINDOWS IN
 SLEEPING ROOMS WITH A MINIMUM NET CLEAR
 OPENING HEIGTH OF 24" AND NET CLEAR
 OPENING WIDTH OF 20" AND A NET CLEAR
 OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR
 OPENINGS ARE PERMITTED TO HAVE A NET
 CLEAR OPENING OF 5.0 SQ. FT. SILL HEIGTH
 SHALL NOT BE MORE THAN 44 " ABOVE THE
 FINISH FLOOR.
 LAWSON SH 34+4 = THE CLEAR HEIGHT IN A
 34 IS 20.09" ADD 1/2 0F 4"=22.09 NOT THE
 REQUIRED 24" MINIMUM.
  
 4) SHEET A-4 GUARDRAILS, REAR ELEVATION,
 MAXIMUM BETWEEN THE DECK AND BOTTOM RAIL
 IS 2".
 1015.2 HEIGHT. GUARDRAILS SHALL
 FORM A VERTICAL PROTECTIVE BARRIER NOT
 LESS THAN 42" HIGH.
 1015.3 OPENINGS. OPEN GUARDRAILS
 SHALL HAVE INTERMEDIATE RAILS OR ORNA-
 MENTAL PATTERNS SUCH AS A 4" DIAMETER
 SPHERE CAN NOT PASS THROUGH. A BOTTOM
 RAIL OR CURB SHALL BE PROVIDED THAT WILL
 REJECT THE PASSAGE OF 2" DIAMETER
 SPHERE.
  
 5) SHEET A-5 JAMB/ HEAD WINDOW BUCKS
 1707.4.4.2 TAPERED BUCKS:
 SHALL EXTEND BEYOND THE INTERIOR FACE
 OF THE WINDOW OR DOOR FRAME SUCH THAT
 FULL SUPPORT OF THE FRAME IS SUPPORTED.
  
 6)1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS SPE
 CIFIED IN THE MATERIALS SECTIONS OF THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23.
 *****USP 2003 CATALOG******
 SHEET A-8 USP RT18 & RT22 HIGH VALUES
 SHEET A-9 TA-12R 895
 TA-14R 1205
 TA-16R 1205
  
 RE-EVALUATE DETAILS (STRAPS) WITH NO
 LOADS INDICATED.
 SHEET A-8& A-9 RE-EVALUATE TRUSS PLAN
 LAYOUT MARKINGS WITH THE NEW LOWER
 VALUES REQUIRED BY THE 2001 FL CODE.
  
 7) MISSING THE INTERNAL PRESSURE COEFFIC
 IENT FOR ENCLOSED BUILDINGS. -.18
 C-1 WIND DESIGN UNDER LOAD SCHEDULE.
  
 MISSING OPENING PRESSURES, POSITIVE/
 NGATIVE.
 FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 8)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)659-8096 X 8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-03-27 Cont ID  
Sent By btrobaug Date 2004-03-27 Time 10:35 Rev Time 0.50
Received By btrobaug Date 2004-03-27 Time 10:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-05-29 Cont ID  
Sent By csiegber Date 2004-03-23 Time 14:41 Rev Time 0.50
Received By btrobaug Date 2003-05-29 Time 11:33 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-04-24 Cont ID  
Sent By shernand Date 2003-05-28 Time 14:31 Rev Time 0.50
Received By btrobaug Date 2003-04-24 Time 09:53 Sent To M
Notes
2003-04-24 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 TO THE PLAN AND RESUBMIT FOR REVIEW.
  
 1} THE #4 GEC IS INCORRECT FOR A 400 AMP
 SERVICE. SEE 250-66.
  
 2} THE FEEDER TO PANEL "B" MUST HAVE AN
 EQUIPMENT GROUND PER 250-122.
  
 3} THE LAUNDRY CIRCUIT MUST BE
 CALCULATED AT 1500 VA PER 220-16-(B).
  
 4} PLEASE LIST THE REQ'D BATH(S)
 CIRCUIT(S). PER 210-11-C-3
 MUST BE 20A AND #12AWG.
  
 5} THE SMOKE DETECTOR IN THE KITCHEN
 MUST BE REMOVED OR BE CHANGED TO A
 LISTED HEAT DETECTOR PER NFPA-72 ART
 8-1.4.2.
  
 6} THE SMOKE DETECTOR AT THE DOOR OF THE
 MASTER BEDROOM MUST BE IN THE VESTIBULE
 TO COMPLY WITH 8-1.4.1.6(2),(OUTSIDE).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2004-03-23 Cont ID  
Sent By csiegber Date 2004-03-23 Time 14:41 Rev Time 0.00
Received By csiegber Date 2004-03-23 Time 14:41 Sent To E
Notes
2004-03-23 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2003-11-18 Cont ID  
Sent By csiegber Date 2003-11-18 Time 16:45 Rev Time 0.00
Received By csiegber Date 2003-11-18 Time 16:45 Sent To P
Notes
2003-11-18 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-10-24 Cont ID  
Sent By csiegber Date 2003-10-24 Time 10:43 Rev Time 0.00
Received By csiegber Date 2003-10-24 Time 10:43 Sent To P
Notes
2003-10-24 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-09-19 Cont ID  
Sent By csiegber Date 2003-09-19 Time 09:44 Rev Time 0.00
Received By csiegber Date 2003-09-19 Time 09:44 Sent To P
Notes
2003-09-19 00:00:00REV P RISER

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-06-17 Cont ID  
Sent By shernand Date 2003-06-17 Time 16:43 Rev Time 0.00
Received By shernand Date 2003-06-17 Time 16:43 Sent To B
Notes
2003-06-17 00:00:00JW DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-06-11 Cont ID  
Sent By shernand Date 2003-06-11 Time 09:33 Rev Time 0.00
Received By shernand Date 2003-06-11 Time 09:33 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-05-28 Cont ID  
Sent By shernand Date 2003-05-28 Time 14:30 Rev Time 0.00
Received By shernand Date 2003-05-28 Time 14:30 Sent To E
Notes
2003-05-28 00:00:00BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-21 Cont ID  
Sent By shernand Date 2003-04-21 Time 09:39 Rev Time 0.00
Received By shernand Date 2003-04-21 Time 09:39 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-05-16 Cont ID  
Sent By btrobaug Date 2003-04-24 Time 10:23 Rev Time 0.20
Received By pkrauss Date 2003-05-16 Time 08:32 Sent To B
Notes
2003-05-16 00:00:00APPROVED 5-13-03 MECH PERMIT 03041504

Review Stop P PLUMBING
Rev No 7 Status P Date 2003-12-22 Cont ID  
Sent By kstevens Date 2003-12-22 Time 15:50 Rev Time 0.33
Received By kstevens Date 2003-12-22 Time 15:50 Sent To  
Notes
2003-12-22 00:00:00REVISION OK - SANT. RISER DIAGRAM.

Review Stop P PLUMBING
Rev No 6 Status F Date 2003-12-06 Cont ID  
Sent By kstevens Date 2003-12-06 Time 19:06 Rev Time 0.50
Received By kstevens Date 2003-12-06 Time 19:06 Sent To  
Notes
2003-12-06 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT THE FLOOR PLAN.
 2) SIGNATURE REQUIRED ON SEAL PER FAC
 61G1-16.003 & FS 481.2055
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 5 Status F Date 2003-10-30 Cont ID  
Sent By csiegber Date 2003-11-18 Time 16:45 Rev Time 0.50
Received By kstevens Date 2003-10-30 Time 15:02 Sent To  
Notes
2003-10-30 00:00:00REVISION DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SANITARY RISER DIAGRAM DOES NOT MEET
 CODE REQUIREMENTS NOR DOES IT REFLECT
 THE FLOOR PLAN. - THE SHOWER IN THE
 MASTER BATH IS NOT VENTED, 901.2.1
 - SEE ORIGINAL SANT. RISER DIAGRAM
 DATED 6-14-3. THAT RISER DIAGRAM MEETS
 THE CODE REQUIREMENTS & REFLECTS THE
 FLOOR PLAN. IF THE FLOOR PLAN HAS BEEN
 CHANGED THEN A REVISION SHALL BE SUBMIT-
 TED FOR THE FLOOR PLAN. IF THE FLOOR
 PLAN IS REVISED, IT SHALL REFLECT THE
 SANITARY RISER DIAGRAM. PLEASE CLAIRFY.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 4 Status F Date 2003-10-06 Cont ID  
Sent By csiegber Date 2003-10-24 Time 10:43 Rev Time 0.50
Received By kstevens Date 2003-10-06 Time 08:29 Sent To  
Notes
2003-10-06 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT THE FLOOR PLAN NOR DOES IS MEET
 CODE REQUIREMENTS.
 - 704.2 THE SIZE OF THE DRAINAGE PIPING
 SHALL NOT BE REDUCED IN SIZE IN THE DIR-
 ECTION OF FLOW.
 - SEE ORIGINAL SANT. RIER DIAGRAM DATED
 6-14-3. THAT RISER DIAGRAM MEETS CODE &
 REFLECTS THE FLOOR PLAN. IF THE FLOOR
 PLAN HAS BEEN CHANGED THEN A REVISION
 SHALL BE SUBMITTED FOR THE FLOOR PLAN.
 IF FLOOR PLAN IS REVISED IT SHALL RE-
 FLECT THE SANT. RISER DIAGRAM.
 PLEASE CLAIRFY.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-06-14 Cont ID  
Sent By csiegber Date 2003-09-19 Time 09:44 Rev Time 0.25
Received By kstevens Date 2003-06-14 Time 08:01 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-05-31 Cont ID  
Sent By kstevens Date 2003-05-31 Time 15:33 Rev Time 0.33
Received By kstevens Date 2003-05-31 Time 15:33 Sent To B
Notes
2003-05-31 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SANITARY RISER DIAGRAM DOES NOT MEET
 CODE REQUIREMENTS. THE SIZE OF THE
 DRAINAGE PIPING SHALL NOT BE REDUCED IN
 SIZE IN THE DIRECTION OF THE FLOW. SEC
 704.2. (BATH #2 THRU KIT) - TUB & SHOWER
 IN MASTER BATH NOT VENTED.- FIXTURES
 FROM LAUNDRY SHALL NOT DRAIN INTO THE
 WET VENT FOR MASTER BATH. 909.1. - DOES
 NOT REFLECT FLOOR PLAN. - SECOND FLOOR
 BATHROOMS/LAUNDRY ROOM SHALL NOT DRAIN
 THRU FIRST FLOOR POWDER ROOM PIPING.
 ---SEE ATTACHED SHEET FOR EXAMPLE OF A
 SAN. RISER DIAGRAM THAT REFLECTS THE
 FLOOR PLAN AND MEETS CODE REQUIREMENTS.-
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-04-23 Cont ID  
Sent By btrobaug Date 2003-05-29 Time 11:43 Rev Time 0.50
Received By jleech Date 2003-04-23 Time 19:24 Sent To E
Notes
2003-04-23 00:00:00DENIED;
 PAGE A-1 PLUMBING RISER DIAGRAM NOT TO
 CODE. SEC. 909.1. WET VENTS FOR BATH-
 ROOMS ARE PERMITTED TO VENT ONLY BATH-
 ROOM FIXTURES. WASHING MACHINE AND
 LAUNDRY TUB ARE REQUIRED TO DISCHARGE
 DOWN STREAM OF THE BATHROOM GROUP.
 RISER DIAGRAM HAS 3 LAVS IN MASTER BATH
 FLOOR PLAN HAS TWO.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT 8369

Review Stop Z ZONING
Rev No 1 Status P Date 2003-04-24 Cont ID  
Sent By shernand Date 2003-04-21 Time 09:40 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved