Plan Review Details - Permit 03041474
Plan Review Stops For Permit 03041474
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-06-18 Cont ID  
Sent By btrobaug Date 2003-09-17 Time 11:54 Rev Time 0.25
Received By jwitmer Date 2003-06-18 Time 11:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-06-16 Cont ID  
Sent By shernand Date 2003-06-17 Time 16:42 Rev Time 0.33
Received By jwitmer Date 2003-06-16 Time 14:20 Sent To  
Notes
2003-06-16 00:00:00COUNTY IMPACT FEES NOT PAID!!!!!!

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-06-06 Cont ID  
Sent By kstevens Date 2003-06-14 Time 08:07 Rev Time 1.25
Received By jwitmer Date 2003-06-06 Time 07:05 Sent To  
Notes
2003-06-06 00:00:00COUNTY IMPACT FEES

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-05-20 Cont ID  
Sent By kstevens Date 2003-05-31 Time 15:26 Rev Time 1.00
Received By jwitmer Date 2003-05-20 Time 15:59 Sent To  
Notes
2003-05-20 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 03041474
 ADD: 6187 HAMMOCK PARK ROAD
 CONT: DOUBLE R BLDG
 TEL: (954)746-0777
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 NOTE: CONTRACTOR IS CONTINEUING AT OWN
 RISK!
  
 NOTES FROM PERMIT 03041478 ARE THE SAME
 THIS IS THE SAME MODEL!!!!
 JIM WITMER

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-03-27 Cont ID  
Sent By btrobaug Date 2004-03-27 Time 10:13 Rev Time 0.50
Received By btrobaug Date 2004-03-27 Time 10:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-09-17 Cont ID  
Sent By csiegber Date 2004-03-23 Time 14:41 Rev Time 0.50
Received By btrobaug Date 2003-09-17 Time 07:31 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-05-29 Cont ID  
Sent By btrobaug Date 2003-05-29 Time 11:32 Rev Time 0.50
Received By btrobaug Date 2003-05-29 Time 11:17 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-04-30 Cont ID  
Sent By shernand Date 2003-05-28 Time 14:31 Rev Time 0.50
Received By btrobaug Date 2003-04-30 Time 07:23 Sent To P
Notes
2003-04-30 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE #4 GEC IS INCORRECT FOR A 400 AMP
 SERVICE. SEE 250-66.
  
 2} THE FEEDER TO PANEL "B" MUST HAVE AN
 EQUIPMENT GROUND PER 250-122.
  
 3} THE LAUNDRY CIRCUIT MUST BE
 CALCULATED AT 1500 VA. PER 220-16(B).
  
 4} PLEASE LIST THE REQ,D BATH(S)
 CIRCUIT(S). PER 210-11-C-3
 MUST BE 20A AND #12AWG.
  
 5} THE SMOKE DETECTOR IN THE KITCHEN
 MUST BE REMOVED OR BE CHANGED TO A HEAT
 DETECTOR PER NFPA-72 ART.8-1.4.2.
  
 6} THE SMOKE DETECTOR AT THE DOOR OF THE
 MASTER BEDROOM MUST BE IN THE VESTIBULE
 TO COMPLY WITH 8-1.4.1.6(2).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-03-23 Cont ID  
Sent By csiegber Date 2004-03-23 Time 14:41 Rev Time 0.00
Received By csiegber Date 2004-03-23 Time 14:41 Sent To E
Notes
2004-03-23 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-09-11 Cont ID  
Sent By csiegber Date 2003-09-11 Time 08:40 Rev Time 0.00
Received By csiegber Date 2003-09-11 Time 08:40 Sent To B
Notes
2003-09-11 00:00:00TO JW DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-06-17 Cont ID  
Sent By shernand Date 2003-06-17 Time 16:42 Rev Time 0.00
Received By shernand Date 2003-06-17 Time 16:42 Sent To B
Notes
2003-06-17 00:00:00JW DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-06-11 Cont ID  
Sent By shernand Date 2003-06-11 Time 09:34 Rev Time 0.00
Received By shernand Date 2003-06-11 Time 09:34 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-05-28 Cont ID  
Sent By shernand Date 2003-05-28 Time 14:31 Rev Time 0.00
Received By shernand Date 2003-05-28 Time 14:31 Sent To E
Notes
2003-05-28 00:00:00BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-18 Cont ID  
Sent By shernand Date 2003-04-18 Time 16:51 Rev Time 0.00
Received By shernand Date 2003-04-18 Time 16:51 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-05-13 Cont ID  
Sent By kstevens Date 2003-05-10 Time 15:17 Rev Time 0.25
Received By pkrauss Date 2003-05-13 Time 09:52 Sent To B
Notes
2003-05-13 00:00:00MECH PERMIT 03041484

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-06-14 Cont ID  
Sent By kstevens Date 2003-06-14 Time 08:07 Rev Time 0.25
Received By kstevens Date 2003-06-14 Time 08:07 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-05-31 Cont ID  
Sent By shernand Date 2003-06-11 Time 09:34 Rev Time 0.33
Received By kstevens Date 2003-05-31 Time 15:19 Sent To B
Notes
2003-05-31 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SANITARY RISER DIAGRAM DOES NOT MEET
 CODE REQUIREMENTS. THE SIZE OF THE
 DRAINAGE PIPING SHALL NOT BE REDUCEN IN
 SIZE IN THE DIRECTION OF THE FLOW. SEC
 704.2 (BATH #2 THRU KIT) - TUB & SHOWER
 NOT VENTED IN MASTER BATH. - FIXTURES
 FROM LAUNDRY SHALL NOT DRAIN INTO THE
 WET VENT FOR MASTER BATH. 909.1 - DOES
 NOT REFLECT THE FLOOR PLAN. - SECOND FLR
 BATHROOMS/LAUNDRY ROOM SHALL NOT DRAIN
 THRU POWDER ROOM PIPING FIRST FLOOR. -
 --- SEE ATTACHED SHEET FOR EXAMPLE OF A
 SANT. RISER DIAG. THAT REFLECTS FLOOR
 PLAN AND MEETS CODE REQUIREMENTS.---
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-05-10 Cont ID  
Sent By btrobaug Date 2003-05-29 Time 11:32 Rev Time 0.33
Received By kstevens Date 2003-05-10 Time 15:13 Sent To M
Notes
2003-05-10 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT THE FLOOR PLAN.
 2) 909.1 WASH MACHINE AND LAUNDRY SINK
 SHALL NOT DRAIN THROUGHT THE WET VENTED
 HORIZONTAL DRAIN OF THE MASTER BATH.
 LAUNDRY FIXTURES SHALL ENTER DRAIN DOWN-
 STREAM OF WET VENTED BATHROOM GROUP.
 3) TOO MANY LAVS FOR MASTER BATH SHOWN
 ON RISER DIAGRAM.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop Z ZONING
Rev No 1 Status P Date 2003-04-25 Cont ID  
Sent By shernand Date 2003-04-18 Time 16:51 Rev Time 0.00
Received By sgraham Date   Time   Sent To E
Notes
***NONE***