| Plan Review Stops For Permit 03041294 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2003-07-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2003-07-08 |
Time |
12:46 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2003-07-08 |
Time |
12:46 |
Sent To |
PC |
|
| Notes |
| 2003-07-08 00:00:00 | STORM SHUTTERS CHECKLIST: | | | 1-REVISE SPACING FOR WOOD ANCHORS. | | | SEE THE ENGINEERED DRAWINGS FOR | | | MINIMUM SPACING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-06-02 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-11 |
Time |
15:26 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2003-06-02 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2003-06-02 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-STORM SHUTTERS INSTALLATION SCHEDULE: | | | REVISE SPACING SPECIFIED FOR ANCHORS | | | IN WOOD FRAMED WALL. SEE ENGINEERING | | | DRAWINGS FOR REQUIRED SPACING. | | | 2-CLARIFY WINDOW "F" FOR SECOND FLOOR | | | BEDROOMS. IS IT SINGLE HUNG OR SLIDER. | | | WINDOW SCHEDULE CALL FOR HS, BUT THE | | | EXTERIOR ELEVATION SHOWS SINGLE HUNG. | | | REVISE AS REQUIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-05-15 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-29 |
Time |
10:13 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2003-05-15 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2003-05-15 00:00:00 | CHECKLIST: | | | 1-SURVEY DOESN'T MATCH FLOOR PLANS | | | SUBMITTED. SURVEY IS FOR MODEL 202, | | | WHILE PLANS ARE FOR MODEL 203. | | | 2-PROVIDE COMPLETE INFORMATION FOR STORM | | | SHUTTERS WITH UPDATED SBCCI REPORT. | | | 3-REVISE DETAIL S21 FOR COLUMN LOCATED | | | BETWEEN GARAGE AND STAIRWAY TO MATCH | | | CONDITIONS SHOWN ON 2ND FLOOR FRAMING | | | PLAN. SECTION 104.2.1.2 OF CITY | | | AMENDMENTS TO FBC 2001. | | | 4-WINDOW 34SH DOESN'T PROVIDE THE 24" | | | CLEAR HEIGHT REQUIRED BY SEC. 1005.4 | | | FBC 2001 FOR BEDROOMS. REVISE AS | | | REQUIRED. | | | 5-ROOF FRAMING PLAN. REVISE CONNECTOR | | | TC-1 SPECIFIED FOR FRAMED WALL. NEED | | | WOOD TO WOOD CONNECTOR. SECTION | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-09-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-09-25 |
Time |
17:01 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2003-09-25 |
Time |
16:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-04-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-19 |
Time |
12:22 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-04-30 |
Time |
06:50 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-09-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-29 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-29 |
Time |
11:14 |
Sent To |
M |
|
| Notes |
| 2003-09-29 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-09-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-19 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-19 |
Time |
12:22 |
Sent To |
E |
|
| Notes |
| 2003-09-19 00:00:00 | TO BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-06-11 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-11 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-11 |
Time |
15:26 |
Sent To |
B |
|
| Notes |
| 2003-06-11 00:00:00 | JGOMEZ DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-05-29 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-29 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-29 |
Time |
10:13 |
Sent To |
B |
|
| Notes |
| 2003-05-29 00:00:00 | JGOMEZ DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-22 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-22 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-22 |
Time |
15:57 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-10-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-10-01 |
Time |
08:28 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2003-10-01 |
Time |
08:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-05-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-29 |
Time |
11:14 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-05-13 |
Time |
10:17 |
Sent To |
B |
|
| Notes |
| 2003-05-13 00:00:00 | MECH PERMIT 03041332 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-05-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-04-30 |
Time |
07:08 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-05-10 |
Time |
14:39 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-04-30 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-22 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
|
Time |
|
Sent To |
E |
|
| Notes |
| 2003-04-30 00:00:00 | | | | SIGNED OFF ON PLANS./WRT |
|
|