Plan Review Details - Permit 03041287
Plan Review Stops For Permit 03041287
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-05-27 Cont ID  
Sent By sthyng Date 2003-06-02 Time 16:31 Rev Time 2.00
Received By sthyng Date 2003-05-27 Time 16:31 Sent To  
Notes
2003-06-02 00:00:00NEEDS IMPACT FEES

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-06-02 Cont ID  
Sent By sthyng Date 2003-06-02 Time 16:17 Rev Time 2.00
Received By sthyng Date 2003-06-02 Time 16:17 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-05-10 Cont ID  
Sent By shernand Date 2003-06-02 Time 13:55 Rev Time 2.00
Received By sthyng Date 2003-05-10 Time 15:00 Sent To  
Notes
2003-05-10 00:00:00*****CORRECTIONS******
  
 1.)SEPARATE PERMITS REQUIRED
 (MECHANICAL).
  
 2.)PROVIDE AREA CALCULATIONS ON THE
 PLAN.
  
 3.)IMPACT FEES ARE REQUIRED TO BE
 PAID AND THE PLANS STAMPED BEFORE THE
 PERMIT CAN BE ISSUED.CALL 233-5025
 FOR MORE INFORMATION.
  
 4.)ENERGY CALCS REQUIRED FBC13-101.2.
  
 5.)PLANS WITH AN ENGINEER'S TITLE
 BLOCK ARE REQUIRED TO BE SEALED, SIGNED
 AND DATED BY THE ENGINEER.
  
 6.)PLAN SHOWS AN 8' GARAGE DOOR,
 PRODUCT APPROVALS ARE FOR 16'.SUBMIT
 NEW PRODUCT APPROVALS.
  
 7.)PLANS REFER TO PRODUCT APPROVAL
 NUMBERS WHICH APPEAR TO BE EXPIRED AND
 WERE NOT PROVIDED WITH THE PLAN.
  
 8.)BUCKS TO PROVIDE FULL SUPPORT,
 REFER TO TYP WINDOW & SGD DETAIL, FBC
 1707.4.4.2.
  
 9.)USP CONNECTOR UPLIFT VALUES HAVE
 BEEN REVISED.REFER TO 2003 CATALOG.
  
 10.)FIRESTOP REQUIRED, FBC 705.3 (NEW
 INT WALL SECTION).
  
 11.)PROVIDE A DETAIL FOR THE NEW
 EXTERIOR WALL.
  
 12.)PROVIDE PRODUCT APPROVALS FOR THE
 ARCHED WINDOW AND THE LOUVERED VENT.
  
 13.)TWO DIFFERENT DOOR SPECS WERE
 PROVIDED.WHICH IS BEING USED AS THE
 EXTERIOR DOOR NEXT TO THE NEW GARAGE
 DOOR?PRODUCT APPROVALS ARE NOT
 REQUIRED FOR INTERIOR DOORS.
  
 14.)TWO DIFFERENT WINDOW PRODUCT
 APPROVALS WERE SUBMITTED.NEITHER WERE
 FOR AN ARCHED WINDOW.
  
 15.)WHEN SUBMITTING PRODUCT APPROVALS,
 BE SURE THAT THEY ARE LEGIBLE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-06-02 Cont ID  
Sent By shernand Date 2003-06-02 Time 13:55 Rev Time 0.00
Received By shernand Date 2003-06-02 Time 13:55 Sent To B
Notes
2003-06-02 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-05-27 Cont ID  
Sent By shernand Date 2003-05-27 Time 16:31 Rev Time 0.00
Received By shernand Date 2003-05-27 Time 16:31 Sent To B
Notes
2003-05-27 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-30 Cont ID  
Sent By shernand Date 2003-04-30 Time 13:17 Rev Time 0.00
Received By shernand Date 2003-04-30 Time 13:17 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-17 Cont ID  
Sent By sgraham Date 2003-04-29 Time 14:44 Rev Time 0.00
Received By shernand Date 2003-04-17 Time 11:22 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-05-03 Cont ID  
Sent By shernand Date 2003-04-30 Time 13:17 Rev Time 0.15
Received By pkrauss Date 2003-05-03 Time 11:34 Sent To E
Notes
2003-05-03 00:00:00NO MECHANICAL PLANS SUBMITTED FOR REVIEW
 PLEASE PROVIDE ENERGY & MANUAL J CALCS
 WITH PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-05-05 Cont ID  
Sent By btrobaug Date 2003-05-05 Time 11:03 Rev Time 0.33
Received By btrobaug Date 2003-05-05 Time 11:03 Sent To B
Notes
2003-05-05 00:00:00 
 OK PER W.R.STAPLES./WRT

Review Stop Z ZONING
Rev No 1 Status P Date 2003-04-29 Cont ID  
Sent By shernand Date 2003-04-17 Time 11:23 Rev Time 0.00
Received By sgraham Date   Time   Sent To I
Notes
***NONE***